Содержание SONOSTAT 135

Страница 1: ...gbo Medizintechnik AG 2004 Version 1 3 Ultrasound Therapy Device SONOSTAT 135 User manual...

Страница 2: ...or omissions All rights reserved No part of this manual may be reproduced in any form or by any means electronic mechanical or otherwise without the prior written permission of the gbo Medizintechnik...

Страница 3: ...l keys of the ultrasound therapy device Lucida in type size 11 Text appears in the display of the ultrasound therapy device Lucida in type size 10 Text appears in the display near the softkey Warnings...

Страница 4: ...3 2 3 Softkey 13 3 2 4 Modifications 13 3 2 5 Ultrasound probes 13 3 2 6 Therapy time 14 3 2 7 Continuous sound 15 3 2 8 Impulse sound 15 3 2 9 Frequency choice 15 3 2 10 Function programs 15 4 THERAP...

Страница 5: ...ell activity particularly in bones In addition biological effects secondary effect Due to thermal and mechanical processes biological effects such as increased membrane permeability and vascular dilat...

Страница 6: ...rasound probe large Therapy time Continuous sound Impulse sound Frequency choice Modification keys Intensity regulator Figure 2 SONOSTAT 135 front Ultrasound probe connections Caution Observe the inst...

Страница 7: ...for calling the main menu There you can select the presettings The softkey is operational This serves for loading your own programs The indication menu can be selected with the softkey Ind 8 In the di...

Страница 8: ...elongs to class IIa Warning 2 2 Connection and switch on The ultrasound therapy device is for the connection with mains voltages from 100 240 V 10 Irrespective of the mains voltage the device is appro...

Страница 9: ...fication of the settings a return is always possible with the softkey Back Modification of the settings 1 Press the softkey menu 2 You are in the menu see Figure 3 Menu 3 Move the scroll bar with the...

Страница 10: ...probe is not coupled Without this linkage set to off the therapy time expires continuously after the first coupling recognition on off on Ultrasound power emission Physical unity of the intensity anno...

Страница 11: ...ound selected frequency or selected indication or selected program coupling indicator softkeys for indication menu or menu Therapy time ultrasound power Coupling indicator here not coupled 10 00 1 8 W...

Страница 12: ...ot operational Table 2 Optical user support keys An optical user support takes place by the LEDs of the ultrasound probe LEDs Condition of the ultrasound probe and coupling indicator flashing Ultrasou...

Страница 13: ...to 0 0 Before changing over from one ultrasound probe to another the intensity regulator has to be set to 0 0 Check the ultrasound power indication on the display 3 2 3 Softkey A softkey is a key wit...

Страница 14: ...not contacted to the patient during therapy no therapy time will pass After reestablishing the contact to the patient the therapy time will pass further The ultrasound probe can be removed at any tim...

Страница 15: ...or with the modification keys to the desired pulse ratio N N 3 Confirm by pressing the softkey select 4 The list will be closed 3 2 9 Frequency choice With the frequency choice key 1 and 3 MHz can be...

Страница 16: ...he softkey You are in the function load program 2 Move the scroll bar cursor by means the modification keys on the desired program NN 3 Confirm by pressing the softkey load 4 The function load program...

Страница 17: ...umstances depends on how successful the treatments are Usually only one or two further treatments are necessary after the symptoms subside A total of 10 to 15 treatments generally suffices Where impro...

Страница 18: ...5 The ultrasound power is indicated on the display 16 Apply light pressure and keep the ultrasound probe flat against the skin moving it in circles or even strokes on the parts to be treated 17 At the...

Страница 19: ...the unit displays the software version it will be operational 3 Connect one or two ultrasound probes to the socket s on the right side of the device 4 The ultrasound probes will be calibrated The LEDs...

Страница 20: ...cture 0 2 3 CW 1 Epikondylitis 0 3 5 1 5 3 Fibrositis 0 3 5 1 5 1 Fracture 0 3 3 CW 1 Gonarthrosis 0 2 3 1 5 1 Hematomas subacut 0 2 3 CW 3 Heberden disease 0 2 3 1 10 1 Intercostalneuralgia 0 2 5 1 5...

Страница 21: ...ONOSTAT 135 in combination with different units than the above mentioned units leads to extinction of gbo Medizintechnik AG s product liability and warranty There is a special input socket provided in...

Страница 22: ...Ind 10 In the display the existing parameters are indicated If wanted you can modify these before the therapy start Note The therapy time can also be set during the therapy 11 Select the desired opera...

Страница 23: ...tages Feverish conditions Poor general condition and general atrophy Active tuberculosis regardless of stage and localization Acute inflammations Stomach ulcers Following recent Thoriam X treatment X...

Страница 24: ...re conditions ERROR with the selftest of the device a failure has appeared 1 Switch off and on again 2 If the failure appears again the device is out of function Please contact a service agent authori...

Страница 25: ...nded to have the device checked by the manufacturer or by a service agency authorized by him at 12 months intervals The check shall consist of at least the following Electrical safety check in accorda...

Страница 26: ...not be excluded Are contraindicated see also chapter 4 3 Changes to the skin particularly with infectious diseases and birthmarks Tumorous diseases in all stages Feverish conditions Poor general condi...

Страница 27: ...use Application part ungrounded protection degree BF The device connection socket which serves the electric connection with an external current therapy device e g DUODYNATOR 119 or HiToP 182 This pro...

Страница 28: ...and 3 325 3 405 MHz Ultrasound probes 2 5 cm2 and 5 cm2 effective emitting surface MDD Device class IIa Safety class I Protection degree BF Protection against ingress of liquids IP X1 Dimensions 12 cm...

Страница 29: ...supply 1 1 1 1 SONOSTAT 135 Ultrasound probe 5 cm2 1 and 3 MHz Contact gel 250 ml User manual German 023 0 0135 Contact gel 250 ml 45 39 128EH725 Ultrasound probe 2 5 cm2 1 and 3 MHz 023 0 0140 Ultra...

Страница 30: ...25 switch on 8 E Einstellungen Grundeinstellungen der Stromformen 11 I Intensit tregler 13 L LED 12 M Main menu Basic settings 9 Device settings 9 Program patient unit 9 modification keys 13 N Note 7...

Страница 31: ...facturer is 10 years SONOSTAT 135 is an electronic device For its disposal the according regulations for electronic devices have to be observed On request the manufacturer will provide you with furthe...

Страница 32: ...nity test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood concrete...

Страница 33: ...80 MHz to 800 MHz d 2 3 P for 800 MHz to 2 5 GHz Where P is the maximum output power rating of the transmitter in watts according to the transmitter manufacturer and d is the recommended separation di...

Страница 34: ...34 SONOSTAT 135 gbo Medizintechnik AG 2004 Version 1 3 Art No 023 7 0004...

Отзывы: