Grey
Y
ellow
White
Green
Red
Black
Power supply
12-24 V DC
Diode
1N4004
provided
(**)
Electrical
lock device -
de-energised
to release
+
Clock
(*)
Push Button
(PTE)
(*)
+
5 - CONNECTION DIAGRAM
5.1 - Electric lock device - de-energised to release
(*)
Clock/Push Button (PTE)
:
Enable relay for "timed relay" (see
chap. 10) or as long as the contact
is closed.
The Push button input does not work
in bistable mode
(**)
Diode 1N4004
:
To be used only with power supply
in DC