Type
Control unit
Electronic control unit for the automation
of a shutter motor
Power supply
N° motors
Motor power supply
Photocell input
Flashing light
Edge input
Accessories power supply
Radio receiver on board
Operating temperature
230Vac monophase 50/60 Hz
1
230 Vac 1200W max
N.C.
230Vac 40W max
N.C.
12Vac 1,2W max
433,92 MHz
-30°C +50°C
AS07200
1 - TECHNICAL SPECIFICATIONS
IT
IT
UK
SR302
13
UK
SR302
12
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Blue LED
Red LED indicating radio codes learning.
Red LED indicating dip Sw1 state.
Flashing light or courtesy light management.
2 possible operation logics: step - step with stop / dead man.
indicating the operating state of the control unit.
Ÿ
Key for transmitters programming and learning on board.
2 N.C. photocell and edge inputs.
Ÿ
Programming of pause time (180 s max.) and working time (150 s max).
Ÿ
Programming «BUTTON UP» input as START or ONLY OPENING.
Ÿ
Radio receiver on board, that can store up to 31 keys or transmitters.
2 - TECHNICAL SPECIFICATIONS / FUNCTIONS
3 - INSTALLATION WARNINGS
• Before proceeding with the installation, it is necessary to fit upstream of the system a magnetothermal
and
differential switch with a max. capacity of 10A. The switch must guarantee an omnipolar separation of the
contacts, with an opening distance of at least 3 mm.
• To avoid any possible interferences, differentiate and always keep separate the power cables (min. section 1 , 5
mm²) from the signal cables (min. section 0,5 mm²).
• Make the connections referring to the following tables and the screen printing on the control unit. Be extremely
careful to connect in series all the devices that must be connected to the same N.C. (normally closed) input
and in parallel all the devices that share the same N.O. (normally open) input. A wrong installation or an
improper use of the product may compromise the safety of the system.
• Keep all the materials contained in the packaging away from children, since they pose a potential risk.
• The manufacturer declines all responsibility for improper functioning of the automated device, if the original
components and accessories suitable for the specific automation are not used.
• At the end of the installation, always carefully check the proper functioning of the system and the devices used.
• This instruction manual addresses people qualified for the installation of “live equipment”. Therefore good
technical knowledge and professional practice in compliance with the regulations in force are required.
• Maintenance must be carried out by qualified personnel.
In the event of an operating fault or failure, cut the power upstream of the control unit and call Technical Service.
Periodically check functioning of the safety devices. Any repairs must be carried out by specialised personnel using
original and certified materials.
The product is not to be used by children or people with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instruction. Do not intervene on the board for
regulations and/or maintenance.
4 - WARNINGS FOR THE USER
• Before carrying out any cleaning or maintenance operation, disconnect the control unit from the mains.
• This control unit may only be used for the purpose for which it was designed.
• The use of the products for purposes different from the intended use has not been tested by the manufacturer,
therefore any work is carried out on full responsibility of the installer.
• Mark the automated gate with visible warning plates.
• Warm the user that children or animals have not to play or stand near the gate.
• Appropriately protect the dangerous points (for example, use a sensitive edge).
WARNING: IMPORTANT SAFETY INSTRUCTION
For people's safety, it is important to follow this instruction.
Please keep this manual.
5 - ELECTRICAL CONNECTIONS: TERMINAL BOARDS
1
3
IN 230Vac
OUT MOTOR CLOSE
OUT MOTOR COM
OUT MOTOR OPEN
OUT LAMP
OUT LAMP
2
4
5
7
6
10
OUT 12Vac
11
Accessories power supply output
Accessories power supply output
Courtesy light / flashing light 230Vac output
Courtesy light / flashing light 230Vac output
Motor connection (opening)
Motor connection (common)
Motor connection (closing)
230 Vac line input (Neutral)
230 Vac line input (Phase)
IN EDGE
IN PHOTO
J2
J1
12
8
14
BUTTON UP
13
9
BUTTON DOWN
Common for Edge, Photocell, Start, Close and Open inputs.
COM
CLOSE command input (N.O.) see DIP8.
START command input (N.O.) if DIP 8 in ON.
OPEN command input (N.O.) if DIP 8 in OFF. See DIP8
Edge input (N.C.) if DIP6 OFF; Stop Input (N.C.) if DIP6 ON
Position
Terminal
Signal
Description
Photocell Input (N.C.) enabled only in closing.
With operation logic:
STEP BY STEP WITH STOP REVERSES THE MOTION
→
DEAD MAN IN CLOSING REVERSES THE MOTION
→
DEAD MAN IN OPENING AND CLOSING STOPS THE MOTION
→