12
I pressed the motor forward
button, but the rolls would
not turn!
a.
Has a speed setting been set?
b. Are the doors closed and shafts
locked in?
c.
Are the e-stop buttons pressed?
Are the kick cables reset?
d. Is there decimal on display?
e.
Check motor fuses on the back of
machine.
a.
Press the FWD or REV arrow and
turn the speed control up.
b. Close the doors and lock in the
unwind/rewind shafts.
c.
Make sure all safety buttons are
released (out). Be sure all kick
cables are reset and adjusted
properly. Press the machine reset
(above main switch). See
"Machine Reset Procedure" on
page 3-3.
Verify that the kick
cable is truly resetting (listen,
look). Adjust the kick cable. See
“Adjusting the Kick Cable” on
page 3-3.
d. Press the machine reset (above
main switch). See "Machine
Reset Procedure" on page 3-3.
e.
Remove fuses and replace, if nec-
essary. Be sure to replace with the
correct size fuses: two 6A fuses
for the motor and one 1A fuse for
the power supply.
13
I pressed the motor reverse
button, but the rolls would
not turn!
a.
see problem 12
a.
See problem 12.
14
I pressed the main roll down
push button, but the roll did
not go down!
a.
Is there air pressure to the
machine?
b. Is there at least 20 psi on the
gauge?
c.
Are the e-stop push buttons
pressed and the kick cables reset?
d. Is the machine reset?
a.
Verify that the air supply is suffi-
cient (
≤
100 psi).
b. Turn up regulator for main roll
pressure.
c.
See problem 12.
d. See problem 12.
e.
Reset the machine. See "Machine
Reset Procedure" on page 3-3.
15
I pressed the main roll up
push button, but the rolls did
not go up!
a.
Is there air pressure to the
machine?
b. Is the machine reset?
a.
Verify that the air supply is suffi-
cient (
≤
100 psi).
b. Reset the machine. See "Machine
Reset Procedure" on page 3-3.
16
I pressed the pull roll down
push button, but the rolls did
not go down!
a.
Is there air pressure to the
machine?
b. Is there at least 20 psi on the
gauge?
c.
Is the roll hook retracted?
d. Are the e-stop push buttons
pressed and the kick cables reset?
e.
Is the machine reset?
a.
Verify that the air supply is suffi-
cient (
≤
100 psi).
b. Increase the pull roll air pressure.
c.
Disconnect and reconnect air
pressure to the machine and
observe pull roll locking mecha-
nism.
d. See problem 12.
e.
Reset the machine. See "Machine
Reset Procedure" on page 3-3.
Problem
Number
Problem
Possible Cause
Corrective Action
Содержание ORCA-IV
Страница 12: ...Safety ORCA IV Image Transfer Laminator Operation Manual 1 8 GBC Pro Tech 1998 October Blank page ...
Страница 20: ...Installation ORCA IV Image Transfer Laminator Operation Manual 2 8 GBC Pro Tech 1998 October Blank page ...
Страница 38: ...Operation ORCA IV Image Transfer Laminator Operation Manual 3 18 GBC Pro Tech 1998 October Blank page ...
Страница 52: ...Warranty ORCA IV Image Transfer Laminator Operation Manual 5 2 GBC Pro Tech 1998 October Blank page ...
Страница 54: ...Specifications ORCA IV Image Transfer Laminator Operation Manual 6 2 GBC Pro Tech 1998 October Blank page ...