9
8. Specifications
IV= Input voltage
OV= Output voltage
CP=Continuous Power
SP=Surge Power
AC product(s) connected are rated at
more than the rated continuous output
power.overload shutdown has occurred.
Use product with a power rating less than the rated
continuous output power;
AC Product is rated less than the rated
continuous output power; high staring
surge has caused overload shutdown.
Product exceeds inverter's surge capability. Use a product
with starting surge power within the inverter's capability.
Battery is discharged (alarm is sounding).
Recharge battery.
Inverter has overheated due to poor
ventilation and has caused over
temperature shutdown.
Switch inverter OFF and allow to cool for 15 minutes.
Clear blocked fan or remove objects covering
unit.Locate unit to a cooler environment.Reduce load
if continuous operation is required, restart.
Input
voltage
is
greater
than
16.0V/31V/61V DC.
Verify charging system is properly regulated and battery is
12V/24V DC nominal.
DC input voltage range
10.5~15.5V (20~31.0VDC)
AC output voltage (nominal)
240VAC
AC output frequency(Pure sine wave)
50/60 ±0.5 Hz
Ambient operating temperature range
-15
℃
~ 50
℃
Low battery alarm trigger range (nominal)
10~10,5VDC (19,5~20VDC)
Low battery shut down range (nominal)
9.0~9.5VDC (18~19VDC)
High battery shut down range (nominal)
15.5VDC (31VDC)
Model
IV
OV
CP
SP
Fuse
Dimension (mm)
Weight (kg)
34.0133.00
12VDC
220~230VAC
300W
600W
1*30A
203*107*62
1.04
34.0133.10
24VDC
220~230VAC
300W
600W
1*20A
203*107*62
1.04
34.0133.20
12VDC
220~230VAC
600W
1200W
2*30A
246*107*62
1.16
34.0133.30
24VDC
220~230VAC
600W
1200W
2*20A
246*107*62
1.16
34.0133.40
12VDC
220~240VAC
1000W
2000W
4*30A
327*180*95
3.3
34.0133.50
24VDC
220~230VC
1000W
2000W
2*30A
327*180*95
3.3
34.0133.60
12VDC
220~230VAC
1500W
3000W
6*30A
405*180*95
4.22
34.0133.70
12VDC
220~230VAC
2000W
4000W
8*30A
405*180*95
5.1