3
personal injury or loss of life.
WARNING!
Shock hazard. Keep away from children.
● The inverter generates the same potentially lethal AC power as a normal household wall outlet. Treat it with the
same respect that you would any AC outlet.
● Do not insert foreign objects into the inverter’s AC outlets, fan or vent openings.
● Do not expose the inverter to water, rain, snow or spray.
● Do not under any circumstances, connect the inverter to utility power AC distribution wiring.
WARNING!
Heated surface.
The inverter’s housing may become uncomfortably warm, reaching
50°C
under extended high power
operation. Ensure at least 5 cm of air space is maintained on all sides of the inverter. During operation, keep
away from materials that may be affected by high temperatures.
WARNING
!
Explosion hazard.
● Do not use the inverter in the presence of flammable fumes or gases, such as in the bilge of a gasoline powered
boat , or near propane tanks. Do not use the inverter in an enclosure containing automotive-type, lead-acid
batteries. These batteries , like sealed batteries, vent explosive hydrogen gas, which can be ignited by sparks
from electrical connections.
● When working on electrical equipment always ensure someone is nearby to help you in an emergency.
CAUTION!
● Do not connect live AC power to the inverter’s AC outlets. The inverter will be damaged even if it is switched off.
● Do not expose the inverter to temperatures exceeding 40°C
CAUTION!
● Connect inverter only to batteries with a 12V/24V/48V DC nominal output. Wrong DC input will not supply
enough voltage or damage the inverter.
CAUTION!
Do not use the inverter with the following equipment:
● Small battery operated products such as rechargeable flashlights, some rechargeable shavers, and
night-lights that are plugged directly into an AC receptacle to recharge.
● Certain battery chargers for battery pack used in hand powered tools. These chargers will have warning labels
stating that dangerous voltages are present at the charger’s battery terminals.
● Connect inverter only to batteries with a 12V/24V DC nominal output. A battery with 6V/12V/24V nominal output
will not supply enough voltage and a battery with 24V/48V/96V nominal output will damage the inverter.
CAUTION!
Any internal adjustment on the inverter is prohibit!
3. Auto protect functions
These advanced safety features are built into the inverter. Electronic overload protection with automatic shutdown.
Built-in internal backup DC fuse provides added safety.
Low battery voltage warning followed by automatic shutdown.
High input voltage protection with automatic shutdown.
Over temperature protection with automatic shutdown.
Output short circuit protection.
4. Product characteristic
Please make sure you have known the basic characteristic of this power inverter before use .