When not using the battery pack for
a longer period, charge it to approx.
60 % (3 to 4 LEDs lit on the charge-control
indicator
A3
).
When the battery pack is stored
discharged (empty) for longer
periods, it can become damaged despite
the low selfdischarging and the battery-
pack capacity may be strongly reduced.
It is not recommended to have the battery
pack connected permanently to the
charger.
Cause
Remedy
2 LED’s flashing
Fault recognised *
Contact your Gazelle specialist
3 LED’s flashing
Outside temperature range **
Take the battery off the charger until it is within the charging
temperature range. Do not connect the battery to the charger
again until it has reached the permitted charging temperature
Geen opladen mogelijk
Check all plug connectors
Carefully clean battery contacts
Check mains voltage, have your charger checked by your
Gazelle specialist
Contact your Gazelle specialist
4.7 FAULT CAUSES AND REMEDIES
* 2nd and 4th LED flashing: A fault has been detected. Contact your Gazelle specialist.
** The 2 outer and the middle LED are flashing: the battery is outside the charging temperature range.
Remove the battery and allow it to reach the correct temperature.