3
enters the temperature protection state and shuts down the motor to ensure device safety.
Display alarm content: [OVER TEMP PROT]
1.4.4 Overvoltage protection function
When the input voltage of the control board exceeds 24V, it will enter the overvoltage protection
state, and the motor drive will be shut down to ensure the safety of the device and the control
board.
Display alarm content: [OVER VOLT PROT]
II.
Technical parameters
Model
ECT-150
Crimping range
Cu10-150 mm²
Force
35kN
Stroke
10mm
Crimping time
About 5s
Oil reservoir
50mL
Battery voltage
DC18V lithium battery
Battery capacity
2.0Ah (Larger battery capacity is optional) 0.36kg
Size
345*90*85mm (without battery)
Charging time
About 40 minutes
Weight
1.84kg (without battery)
III.
Safety precautions
3.1
Safe operation
3.1.1 Keep the working area clean and bright, chaos or lack of light may cause accidents.
3.1.2 The tool is not insulated. Do not use it for live conductors.
3.1.3 Do not use or store tools around high temperature or corrosive liquids to prevent aging of
sealing components.
3.1.4 When operating hydraulic tools, do not point the head to other people, and keep away from
children and bystanders. Distraction during work may cause the tools to lose control.
3.1.5 Keep high vigilance when operating tools, fully grasp the situation, and engage in operations