6
General Installation Guidelines
•
Before beginning, carefully read this installation guide. Please keep this
booklet for future use and reference.
•
After opening the product’s package, make sure the device is in good
condition, and there is no visible damage. If you have any doubt about the
product’s integrity, please contact Gauzy’s support center immediately
([email protected]).
•
Before connecting the device for the first time, make sure the voltage and
frequency of your AC network match the electrical specification of this unit.
•
Before connecting this unit to the film, make sure the controller model
matches the
electrical specification requirements.
•
Proper use of this device requires connecting the AC input GROUND
terminal to earth.
•
The electrical connections of this device must be made by a qualified
electrician.
•
This device was designed to control Gauzy films. Connecting this device to
other types of loads rather than Gauzy films may damage the device. Gauzy
Ltd. will not be responsible for any damage caused by inappropriate use of
this device.
•
This device is for indoor use only.
•
This device is to be used in a permanent connection.
The following table describes the wires and conductors that must be used for the
installation:
AC Input & HV Controls
At least 1mm
2
/16AWG Conductors rated for 110/220 VAC
Dry Contacts LV Controls
18 - 24AWG wires. Preferred solid conductors
AC OUT (Connection to Gauzy
film)
At least 0.2mm
2
/24AWG conductors (*)
(*) – Conductor thickness depends on the total area of Gauzy film connected
and the distance of the Gauzy film to the controller.
•
The connection of the controller to the electrical cabinet should always be
done through a circuit breaker with a rating of 6-10A type B.
•
This device can be installed inside an electrical cabinet or mounted on a wall.
•
The installation should always allow enough space for natural ventilation of
the unit.
•
Never leave wire conductors exposed. If needed, use isolation tape to cover
the unit’s terminals.
In order to comply with electromagnetic regulations, the use of the ferrite ring
included in this package is needed.
Please wind the output cable 2 turns around the ring near the output connector as
shown in the illustration below:
Содержание LC6 FLEX Controller
Страница 25: ...25 Basic Wiring Diagram On Off DMX Quick Reference Guide ...
Страница 26: ...26 Basic Wiring Diagram Dimmer DMX ...
Страница 27: ...27 Basic Wiring Diagram DMX DMX ...
Страница 28: ...www gauzy com support gauzy com TN 09 12 01 ...