background image

 

S200 & S201 

Susie Simon

® 

User Guide

Simple Simon is an interactive educational system developed to assist a certified 
instructor. It is not a substitute for a comprehensive understanding of the subject 
matter and not intended for clinical decision making.

User Guide 20.1.1

©2020 Gaumard Scientific

All Rights Reserved

www.gaumard.com

Содержание Susie Simon S200

Страница 1: ...educational system developed to assist a certified instructor It is not a substitute for a comprehensive understanding of the subject matter and not intended for clinical decision making User Guide 20...

Страница 2: ...orage Conditions 2 Procedures 2 Cleaning 2 Stoma Care 3 2 Getting Started 4 2 1 Overview 4 Airway 4 Appearance 4 General Patient Care 4 Options 4 2 2 Terminology 5 Facilitator 5 Provider 5 3 Equipment...

Страница 3: ...oot 17 5 3 Patient Training Arm 17 Features 18 5 4 Heart and Lung Sounds 18 5 5 Setup 18 5 7 Subclavian Access S201 707 21 Setup 22 Using the Subclavian Access 23 Replacing the Subclavian Vein 24 6 Ap...

Страница 4: ...provided simulated blood Any other simulated blood containing sugar or any additive may cause blockage and or interruption of the vasculature system The use of needles larger than 22 gauge will reduc...

Страница 5: ...n very difficult and is likely to result in damage to the simulator When simulating drug administration via endotracheal tube providers must use an empty syringe Passing liquids into the trachea or es...

Страница 6: ...rfaces ink or newsprint The stoma material is absorbent Prevent items from resting or pressing against the stomas as indentations will form on the pressure points The stomas may return to the normal s...

Страница 7: ...h the following features Airway Tracheostomy Care Nasal and oral tube feeding and gastric suctioning Appearance Realistic eyes for ophthalmic exercises Realistic face skin hands feet fingers and toes...

Страница 8: ...01 User Manual Getting Started 5 2 2 Terminology Facilitator The person conducting the simulation an instructor or lab staff member Provider A person participating in the simulation as a healthcare pr...

Страница 9: ...ntestinal procedures and enema administration Stylish wig for haircare exercises and surgical draping Amputation stump O O Two decubitus ulcers O O Ulcerated foot O O Articulating head jaw elbows wris...

Страница 10: ...sembled Perform the following steps to install the legs Leg Assembly 1 Place simulator on a flat surface On each leg washers spring and wing nut is in place 2 Remove the wing nuts washers and springs...

Страница 11: ...nt Setup 5 Reach through the IM site and assemble the fasteners onto the hip bolt Assemble in this order washer spring washer and wing nut 6 Tighten the wing nut until the spring is compressed slightl...

Страница 12: ...t open and close permitting the following exercises Administration of orbital medicines into the conjunctival sac Removal of foreign bodies Eye irrigation Teeth The simulator is supplied with normal s...

Страница 13: ...pper or lower jaw and tap lightly Dentures will immediately snap out 2 To reinsert gently hold lower or upper lip and replace dentures Bandaging The fingers and toes of the simulator are separated to...

Страница 14: ...ice syringing exercises WARNING Always use lubricant prior to introducing an invasive device Range of Simulated Movement The joints are strong and their movements are lifelike and realistic The simula...

Страница 15: ...mon S200 Stoppers Use the stoppers provided to seal the reservoir bags Gastrostomy A gastrostomy left port located near the waist connects directly to the stomach tank Tank Capacity Stomach 500 ml Ost...

Страница 16: ...articulate to permit enema exercises with the simulator on its back The enema should be introduced with an anal nozzle of small diameter A non return valve is built into the anal canal to prevent flu...

Страница 17: ...syringe to fill the bladder Urinary Catheterization The simulator includes a fitted female genitalia and a male genitalia attachment Assembly Instructions 1 To attach the male genitalia remove the red...

Страница 18: ...cedure 1 Fill the bladder 2 Place the stopper in the port 3 Lubricate the size 18 Fr catheter 4 Insert the catheter 5 To increase the pressure and the urine flow use the squeeze bulb on the right side...

Страница 19: ...voir by inserting a solution of water and alcohol 70 30 and draining the reservoir Cleaning the Reservoirs In order to clean out the reservoirs follow the steps below 1 Unscrew the waist knobs 2 Remov...

Страница 20: ...d stage 5 2 Ulcerated Foot Diagnose and treat ulcers on the left foot of the simulator 5 3 Patient Training Arm WARNING Vein tubing contains latex which may cause allergic reactions Users allergic or...

Страница 21: ...e has incorporated Power button Sound menu button The torso of the simulator has numerous removable identification dots located where each of the heart and lung sounds are normally heard These colored...

Страница 22: ...easily heard during inspiration and the second sound is single during expiration The second component of the split sound P2 is accentuated Split S2 S2 is variably split during mid inspiration as three...

Страница 23: ...longer than the one between expiration and inspiration Trachea Stridor Sounds Patient has marked respiratory distress and a narrow aperture between the vocal cords that produces a high pitched tone d...

Страница 24: ...ch than crackles Posterior Four Sites Medium Fine Crackles These noises begin about mid inspiration and progressively increase in intensity up to the end of expiration Coarse crackles are also audible...

Страница 25: ...or s right side 3 Connect the fill syringe to one of the ports on the right side of the simulator NOTE It does not matter which port the fill syringe is connected to 4 Connect the drain hose to the ot...

Страница 26: ...imed 5 Inject the fluid into the simulator and keep injecting until there are no more air bubbles in the drain hose Using the Subclavian Access 1 With the clamp closed push 1 2 mls of fluid to pressur...

Страница 27: ...he clamp to drain the fluid from the vein 3 When there is no fluid in the line unscrew the waist knobs 2 Fill the syringe with air and connect it to one of the ports on the simulator s right side Push...

Страница 28: ...201 User Manual Options 25 4 Remove the waist rod 5 Separate the lower torso from the upper torso 6 Disconnect the stomach from the lower torso 7 Reach into the upper torso and release the quick conne...

Страница 29: ...S200 S201 User Manual 26 Options 10 Insert one end of the new vein 11 Connect the new vein to the quick connector 9 Remove the old vein 8 Lift the chest skin...

Страница 30: ...27 12 Insert the other end of the vein and connect it to the quick connector 13 Replace the chest skin 14 Connect the stomach reservoir back to the lower torso 15 Attach the lower torso to the upper t...

Страница 31: ...rts List Contact Gaumard Scientific for a complete list of consumables and replacement parts and their prices Item Type Code Arm Injection Sites Consumable S200 857 1 L M D Buttock Injection Sites Con...

Страница 32: ...ession or otherwise dispose of Products for which payment is overdue 4 Product Shipment and Risk of Loss Unless otherwise agreed to in writing by Gaumard all Products will be shipped F O B Origin rega...

Страница 33: ...like Licenses even if applied for by Gaumard on Customer s beHAL f If any authorization is delayed denied revoked restricted or not renewed Gaumard sHAL l not be liable and Customer is not relieved o...

Страница 34: ...voluntary or involuntary bankruptcy proceeding is instituted by or against a Party hereto or 3 an appointment of a receiver or assignee for the benefit of creditors occurs on beHAL f of a Party heret...

Страница 35: ...or make available to other parties the Gaumard Software in source code format 2 8Certification Upon thirty 30 days written notice to End User from Gaumard End User sHAL l certify End User s compliance...

Страница 36: ...c when received if sent by certified or registered mail postage prepaid return receipt requested Any such notice given to a party sHAL l be sent to the addresses on the attached Purchase Order By givi...

Страница 37: ...oduced by Gaumard This limited warranty does not apply to any products provided along with the Gaumard product that are manufactured by third parties For example third party products such as computers...

Страница 38: ...ess to the simulator for possible troubleshooting as needed Technical Support Email support gaumard com USA 800 882 6655 INT 01 305 971 3790 7 2 General Information Sales and Customer Service E mail s...

Страница 39: ...belt Susie Krash Kids Premie UNI Omni SmartSkin OMNI and OMNI 2 are trademarks of Gaumard Scientific Company Always dispose of this product and its components in compliance with local laws and regulat...