Instruction Manual 

S410.100 Blood Pressure Training System with Speakers  

 

Copyright 2010 by Gaumard® Scientific.  All rights reserved. 

 

 
 

I. 

Introduction 

 

A. Description 

 
The 

Gaumard® S410.100 

Blood Pressure Training system with speakers includes a full-size 

adult 

left

 arm.   

 
This is a versatile training tool developed to assist health professionals teach the processes 
and skills required to perform blood pressure auscultation procedures and techniques. 
 
The Blood Pressure Training System features the following: 
1. 

Programmable, palpable radial pulse when cuff pressure is less than the selected 
systolic blood pressure 

2. 

Korotkoff sounds K1 through K4 (K5 is silence) audible between systolic and diastolic 
pressures. 

3. 

Korotkoff sounds are automatically silenced if auscultation gap is selected 

4. 

Korotkoff sounds are automatically adjusted depending upon selected heart rate and 
the rate of cuff deflation. 

5. 

Conventional stethoscope to Auscultate Korotkoff sounds in the antecubital area 

6. 

Conventional sphygmomanometer with tubing assembly. 

7. 

Programmable Blood Pressure Auscultation Tutor 

a.  Adjustable systolic and diastolic pressures 
b.  Adjustable auscultation gap 
c.  Adjustable pulse rate 
d.  Display tracks cuff pressure 
e.  Three point calibration control (000/128/256) 

8. 

International power supply 100 to 240 VAC 

9. 

Speakers with volume control allow students to hear what the individual student hears 
while using the stethoscope 

10. 

Soft carrying bag 

11. 

Instruction Manual. 

 
 

Содержание S410.100

Страница 1: ...be used as part of an approved educational program for healthcare It is not a substitute for traditional learning methods and should not be used for clinical decision making Instruction Manual 2010 Ga...

Страница 2: ...PRIOR TO COMMENCING TRAINING EXERCISES ON YOUR NEW SIMULATOR HANDLE YOUR SIMULATOR IN THE SAME MANNER AS YOU WOULD HANDLE YOUR PATIENT WITH CARE AND CONSIDERATION SHOULD YOU HAVE ANY QUESTIONS AFTER...

Страница 3: ...ts reserved 3 Contents Contents 3 I Introduction 4 A Description 4 B Inventory 5 II Instructions for Use 6 A Assembly of Simulator 6 B Calibration 7 C Changing Factory Settings 7 D Blood Pressure Trai...

Страница 4: ...through K4 K5 is silence audible between systolic and diastolic pressures 3 Korotkoff sounds are automatically silenced if auscultation gap is selected 4 Korotkoff sounds are automatically adjusted d...

Страница 5: ...m Quantity Description 1 1 BP arm with internal speaker and mounted pulse 2 1 BP Cuff Kit BP Cuff with Pressure tube Luer connector Stethoscope and Carrying Bag 3 1 International Power Supply 110 to 2...

Страница 6: ...extending from the sphygmomanometer assembly to the BP Tutor 5 Connect the speakers to the BP Tutor and electrical power outlet 6 Wrap the blood pressure cuff around the arm midway between the deltoi...

Страница 7: ...e cuff to read 256 and press Calibrate Start again 8 At this time the BP Tutor will display the reading on the sphygmomanometer Lower the cuff pressure to zero and watch the display track the sphygmom...

Страница 8: ...he blood pressure by installing the BP cuff and place the bell of the stethoscope over the speaker concealed in the antecubital region of the arm near the elbow The instructor may wish to press on the...

Страница 9: ...lugged into the Blood Pressure Auscultation Tutor Check that internal pins on the connector are not bent or broken 2 If the calibration feature was initiated simulator will not exit this mode until ca...

Страница 10: ...p and water Do not clean with harsh abrasives After cleaning and drying the arm lightly dust it with talcum powder This will keep the training arm supple and easy to use Note Dust the inside and outsi...

Страница 11: ...100 009 One Replacement Parts Blood Pressure Auscultation Tutor 410 100 001 One Power Supply 100 240 VAC power cord 110 or 220 VAC Country 410 100 005 One Blood Pressure Cuff Kit 410 100 002 BP Cuff...

Страница 12: ...s E mail sima gaumard com Online catalog at www gaumard com Phone toll free in the USA 800 882 6655 worldwide 305 971 3790 fax 305 667 6085 Note Before contacting Gaumard you must 1 Have the manikin s...

Отзывы: