Input Setting

The input selction switch is placed on the back of the amplifi er by the input connectors. Use this to select wether RCA or XLR input is active.

Protection warnings

The PWR-222 is equipped with a sophisticated protection circuit to protect the amplifi er and/or the connected 
equipment in case of failure. The PWR-222 features three warning signals:

Temperature:

If the amplifi er develops too much heat and reach a high internal and external temperature it will automatically 
shut down. During this fail condition the “temp” and the standby LED will fl ash. Please turn off  the amplifi er 
by the mains switch on the back, allow a 10 minutes cooling time and check following points before turning 
the amplifi er on again:

•  The ventilation around the amplifi er

•  The speaker cable and cable connections

• The 

specifi cation of the connected loudspeakers

Clipping and DC: 

This failure can either be generated by too high listening volume with large amount of clipping and distortion, 
or by a malfunction in the connected equipment. The amplifi er will shut down and the “VU” and standby LED 
will fl ash. Please turn off  the amplifi er by the mains switch at the back. Before switching on the amplifi er again, 
please check the following:

•  The speaker cables and cable connections

•  The connected equipment

•  That the volume is set below the amplifi ers clipping range

If the warning lights keep fl ashing after the power up routine, please turn off  the amplifi er and contact your 
dealer or the national distributor.

Short Circuit:

During a short circuit of the amplifi ers output or a failure from the components inside, the amplifi er will shut 
down and the standby LED will fl ash. Please turn off  the amplifi er by the main switch. Before turning on the 
amplifi er please:

•  Remove speaker cables and other cable connections (except mains cable)

•  Check the connected cables and equipment

•  Check that the volume is set below the amplifi ers clipping range.

If the warning lights keep fl ashing after the power up routine, please turn off  the amplifi er and contact your 
dealer or the national distributor.

Temperature Warning

Short Circuit Warning

Clipping and DC Warning

VU

Содержание PWR-222

Страница 1: ...PWR 222 Mono Power Amplifier User Manual ...

Страница 2: ...Gato Audio PWR 222 Mono Power Amplifier Page 2 ...

Страница 3: ...ET Power Amplifier 6 Protection Circuits 6 Components 6 Fine Tuning by Listening 6 Setting up your amplifier 7 Basic connection 7 Overview 7 How does it work 8 Power on 8 Standby 8 Display modes 8 VU Meter 8 Temperature 8 Dim 8 Input Setting 9 Protection warnings 9 Make it last 10 If all else fails 10 Technical specifications 11 ...

Страница 4: ...ing up for our newsletter to receive information about exciting new products events and technical updates We are also present on several social media like Facebook Twitter Instagram Google and LinkedIn All this and more on www gato audio com Our very best Gato Audio Package contents Please check that the following is included in the package 1 Gato Audio PWR 222 mono power amplifier 1 Mains cable 1...

Страница 5: ...d This is not a toy and should not be handled like one by children OR adults Do not remove the covers of the amplifier for service see page 10 Do not attempt to put foreign objects inside the amplifier for service see page 10 Do not cover the amplifier with cloth Do not place the amplifier on sloped or unstable surfaces When the amplifier will not be used for a long time remove the mains plug Neve...

Страница 6: ...se and faults Heat current and DC are under constant surveillance by a microprocessor which will shut down the amplifier if the accepted values are exceeded Components Every single component in the PWR 222 must live up to not only stringent production tolerances and over specified values but equally importantly it will not be selected before having been approved for its sonic capabilities through ...

Страница 7: ... on 5 Enjoy Overview Made in Denmark RCA XLR Link DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL TO REDUCE THE RISK OF ELECTRICAL SHOCK OR FIRE DO NOT EXPOSE THIS APPLIANCE TO MOISTURE OR RAIN Speaker Input Mains Live Neutral PWR 222 Standby Display VU Speaker terminals Mains socket Balanced input Standby button Display button Analogue input 12 V trigge...

Страница 8: ...re described below To select a display mode simply press the Display button on the front panel of the amplifier The display will switch modes in this order VU Meter Temperature Display Dim VU Meter TheVU meter display mode shows the output power of the amplifier The pointer responds to peaks on a scale illustrated by two white end brackets The red bracket indicates 0 dB Temperature The PWR 222 cor...

Страница 9: ... distortion or by a malfunction in the connected equipment The amplifier will shut down and the VU and standby LED will flash Please turn off the amplifier by the mains switch at the back Before switching on the amplifier again please check the following The speaker cables and cable connections The connected equipment That the volume is set below the amplifiers clipping range If the warning lights...

Страница 10: ...careful never to use hot water or any type of concentrated detergent solvent thinner or any other volatile substance on the surfaces or you may cause permanent damage to the surface coating Keep the cabinet away from prolonged contact with rubber or PVC materials Do not expose the amplifier to direct sunlight or other heat sources If all else fails don t panic Every Gato Audio product comes with a...

Страница 11: ...er 12 V Size Power Power Requirements Fuse Power consumption stdb idle max Dimensions WxHxD Weight 1x 250 W RMS 8 Ω 1x 450 W RMS 4 Ω 20 Hz 20 kHz 0 1 dB and 2 Hz 100 kHz 3 dB 0 003 115 dB 100 kΩ RCA and 100 kΩ Balanced 26 dB 4 16 Ω Speakers 1 5 Ω 1 pc of gold plated XLR Neutrik 1 pc of gold plated RCA 1 pair of WBT NextGen 1 mini jack 115 VAC 230 VAC 50 Hz 60 Hz 800W max 20 mm sand filled 6 3 AT 1...

Страница 12: ...Gato Audio Marielundvej 28 DK 2730 Herlev Denmark Phone 45 4095 2205 www gato audio com hello gato audio com 510015 GA PWR 222 MAN 1 0 1509 ...

Отзывы: