GT510 ATF System Service Centre
8
4. Adjusting fluid level
4.1 Increase fluid amount
When the fluid in transmission is not enough, supply it with the desired amount of fluid.
Select adjust function, set the amount of add new fluid, press ENTER button to run.
4.2 Decrease fluid amount
If the quantity of the ATF is more than the standard amount, it is necessary to decrease
the fluid amount inside transmission.
Select adjust function, set the amount of return used fluid, press the ENTER key to run.
5. Empty new fluid tank/used fluid tank
1) Select the empty fluid tank function
2) Connect the drain oil pipe to the drain oil port of the unit. Prepare a wasted fluid tank.
3)
Choose the need to
empty fluid tank, press the ENTER key to run.
4) The unit will stop after the fluid tank is empted..
6. System setting
1)
Select the system setting function.
2)
Select each function to operate.
6.1 Parameter setting
Language : English and Chinese
Unit: metric, Imperial and U.S.
6.2 Calibration
1) New fluid / used fluid tank sensor
It will require setting the weight of weights during calibration. The weight of weights range is 10kg~20kg.
The calibration can be performed steps by the prompts of LCD panel.
2) New fluid / used fluid temperature
Perform the calibration when the equipment is power down. Input the current temperature.
3) Detergent flow
Fill enough detergent into detergent bottle. Set the amount of detergent need to fill out. And press
[FINISH] when the setting amount detergent is fill out.
6.3 Pipelines self-clean
Fill new fluid which is different from the fluid before into the new tank. It will clean the pipelines through
this function.
6.4 System inquiry
It can inquire the total times of service.
6.5 Printer test(optional)
It can check if the printer is normal.