Instructions for SL500DCL/SL800DCL
www.gatexpertstore.com
35
OSC: Single button control
PED: Pedestrian button
STP: Stop button
Special function: Only the gate is completely open, can it be closed thereafter. If the gate is
not completely open, then only opening and stop can be operated in order to prevent any
interruption which will trigger closing during the opening travel operated by the first user.
A.
Operation Instruction:
1.
Press and hold “PROG” button for 3 sec. to enter into basic menu.
Indicator light L0
will flicker once, then L1 will be steady on.
2.
Press “PROG” button again for 3 sec. to enter into advanced menu.
Indicator light L0
will flicker twice, then L1 will be steady on.
3.
Press “SET” button once to enter into working mode setting.
Indicator lights L1-L3
will show the current selection. (The default is L1)
4.
Press “+” or “-” button to select the working mode.
Indicator lights L1-L3 will show the
current selection.
5.
Press” SET” button once to save and system will automatically exit.
The indicator
lights L1-L5 will be on in sequence, then all will flicker once and off.
B. Operation Graphic Illustration
Press “PROG” for
3 sec.
L0 flicker once, L1
will be steady on
Press “PROG”
again for 3 sec.
L0 flicker twice, L1
will be steady on
Press “SET” once
Press “SET” once
Press “+” or “-” to set, LED
will show the setting value
Save and exit
SET
SET
PROG
PROG
L1-L5 will be on in
sequence then all
flicker once and off.