background image

 

 

 

 

 

 

Publication Information 

©2014 GatesAir, Inc. . Proprietary and Confidential. 
GatesAir considers this document and its contents to be proprietary and confidential.  Except for making a 

reasonable number of copies for your own internal use, you may not reproduce this publication, or any part 

thereof, in any form, by any method, for any purpose, or in any language other than English without the written 

consent of GatesAir. All others uses are illegal. 
This publication is designed to assist in the use of the product as it exists on the date of publication of this manual, 

and may not reflect the product at the current time or an unknown time in the future. This publication does not in 

any way warrant description accuracy or guarantee the use for the product to which it refers.

 

GatesAir reserves the right, without notice to make such changes in equipment, design, specifications, 

components, or documentation as progress may warrant to improve the performance of the product. 
GatesAir reserves the right, without notice to make such changes in equipment, design, specifications, 

components, or documentation as progress may warrant to improve the performance of the product. 

Trademarks  

AudioLink PLUS™, HD Link™, IntraGuide

®

, Intraplex

®

, NetXpress™, NetXpress LX™, STL PLUS

®

, SynchroCast

®

, and 

SynchroCast3™ are trademarks of GatesAir Corporation. Other trademarks are the property of their respective 

owners. 

Customer Service Contact Information 

www.gatesair.com 

GatesAir

 

3200 Wismann Lane 
Quincy, Il 62305 USA 
 

For Technical Support including Service, Training, Repair and Service Parts: 

www.gatesair.com/services/technical-support.aspx 

Americas: 

24/7 Technical Support 

+1 217 222 8200 

Email 

[email protected] 

 

Europe, Middle East and Africa: 

24/7 Technical Support 

+1 217 222 8200 

Email 

[email protected] 

 

Asia: 

24/7 Technical Support 

+1 217 222 8200 

Email 

[email protected] 

 

Содержание Intraplex DA-191B

Страница 1: ...GatesAir com Intraplex DA 191B Four Port Asynchronous Data Module Version 1 Installation and Operation Manual...

Страница 2: ......

Страница 3: ...anges in equipment design specifications components or documentation as progress may warrant to improve the performance of the product GatesAir reserves the right without notice to make such changes i...

Страница 4: ...Version numbers usually correspond to software releases If the manual versions differ in number from the release the front page shows both the manual version and the release version...

Страница 5: ...6 2 7 1 Configuring the Data Ports 8 2 7 2 Time Slot Selection 8 2 7 3 Other Configuration Options 9 2 6 Remote Control Interface 10 2 6 1 P Codes 11 2 6 2 S Code 15 Section 3 Installation Procedure 1...

Страница 6: ...3 Data Port Configuration S1 Positions 1 3 8 Table 2 4 Time Slot Selection S1 Positions 4 8 9 Table 2 5 Configuration Switches S2 10 Table 2 6 Card Address Setting S3 11 Table 2 7 Remote Configuratio...

Страница 7: ...d Drop Insert Multiplexers The module provides transmission of one to four asynchronous data channels over T1 E1 and other digital communications facilities with either an RS 232C or an RS 449 data in...

Страница 8: ...aling The TERM switch determines whether the module is set up for use in a terminal multiplexer or a drop insert multiplexer In a drop insert multiplexer it also determines whether the module communic...

Страница 9: ...EMOTE SRVC DATA IN DATA OUT S3 1 2 3 4 5 6 SET CARD ADDRESS S1 1 2 3 4 5 6 7 8 SELECT TIME SLOT S CH2 CH3 CH4 MODULE ADAPTER CH2 CH3 CH4 TX DATA RS 232 SEND DATA A B RS 449 CTS RS 232 only CARRIER DET...

Страница 10: ...begins on any active channel and remains lit while transmission continues 2 3 Receive Side The multiplexer common module demultiplexes the aggregate receive signal and passes the data for the selecte...

Страница 11: ...nd receive via the DI A port toward Site 1 and UP to transmit and receive via the DI B port toward Site 3 Site 2 Drop and Insert Multiplexer Through Channels Site 3 Terminal Multiplexer To From Site 1...

Страница 12: ...the far end a single DA 191B module may be set to use two time slots and establish circuits with both of them 2 7 Controls and Indicators The DA 191B has three sets of switches and three LED indicator...

Страница 13: ...ATE 0 MODE TIME SLOT SELECT S2 S1 S3 1 2 ON 3 4 5 6 SCB ADDRESS DATA OUT IMPORTANT All modules must be inserted so that the white eject tab is at the bottom in a full size 5 1 4 high shelf and at the...

Страница 14: ...s Maximum Activates No Of Restricted E1 RATE 1 RATE 0 MODE Data Rate Port Nos Time Slots Time Slots UP DOWN DOWN 38 4 kbps 1 2 15 16 UP DOWN UP 38 4 kbps 1 and 2 4 13 16 UP UP DOWN 38 4 kbps 1 to 4 8...

Страница 15: ...U U D U D 7 6 U U D D U 8 7 U U D D D 9 8 U D U U U 10 9 U D U U D 11 10 U D U D U 12 11 U D U D D 13 12 U D D U U 14 13 U D D U D 15 14 U D D D U 16 15 U D D D D 17 16 D U U U U 18 17 D U U U D 19 1...

Страница 16: ...or local control Sets module for remote control OFF UP DOWN Normal operation module is active Turns service off 2 6 Remote Control Interface DA 191B modules installed in an Intraplex remote controllab...

Страница 17: ...0 1 35 1 0 0 0 1 1 18 0 1 0 0 1 0 36 1 0 0 1 0 0 0 OFF 1 ON The DA 191B reports itself as a TYPE 115 card Its remote operation involves two sets of codes P parameter codes and S status codes as descri...

Страница 18: ...with four active ports maximum data rate 9 6 kbps per port to use two time slots starting at time slot 3 P2 Module is set to communicate via the DI A TERM port in a drop insert multiplexer the data l...

Страница 19: ...ngs P2 B00000000 CAS 0 1 Normal Reserve time slot 16 for CAS signaling in an E1 multiplexer only B00000000 T1 0 1 Sets the module to operate in an E1 2 Mbps multiplexer Sets the module to operate in a...

Страница 20: ...Bxxx00001 2 Bxxx00010 3 Bxxx00011 4 Bxxx00100 5 Bxxx00101 6 Bxxx00110 7 Bxxx00111 8 Bxxx01000 9 Bxxx01001 10 Bxxx01010 11 Bxxx01011 12 Bxxx01100 13 Bxxx01101 14 Bxxx01110 15 Bxxx01111 16 Bxxx10000 17...

Страница 21: ...is one S code for the DA 191B It is a response to a STATUS query and indicates transmit and receive activity as shown in Table 2 10 The S code is shown in both decimal and binary form A typical respon...

Страница 22: ...1 positions 1 3 as described in Table 2 3 3 Select the desired starting time slot using the TIME SLOT SELECT switches S1 positions 4 8 as described in Table 2 4 4 Set for use in a terminal or drop ins...

Страница 23: ...ote control REMOTE switch DOWN Do not turn service on 6 Reinstall the module 7 Verify the configuration via remote control by issuing a CONFIG query See Section 2 6 2 Remote Configuration Codes for an...

Страница 24: ...ON and set the multiplexer at one end of the circuit to use loop timing 2 Connect a data error analyzer Telecommunication Techniques Corp Fireberd 2000 or equivalent to the jack for channel one on th...

Страница 25: ...4 kbps 4 s p p 19 2 kbps 8 s p p 9 6 kbps 16 s p p Time Slots Depending on data rates any one time slot or up to eight contiguous time slots RS 232 Interface MA 404 Supports TX Data RX Data Clear to...

Страница 26: ......

Страница 27: ...SD A SD B RD A RD B Both of these module adapters provide RJ 11 connectors for the data ports Active ports are numbers 1 through n where n is the number of active data channels Thus for single channe...

Страница 28: ...the MA 404 has five data ports Only the ports labeled CH 1 through CH 4 are used with the DA 191B module RJ 11 Jack Pin 1 Pin 6 Pin Assignments for the RJ 11 Jacks on the MA 404 Module Adapter RJ 11...

Страница 29: ...input jack arrangement and defines the pin assignments for the MA 418 RJ 11 Jack Pin 1 Pin 6 Pin Assignments for the RJ 11 Jacks on the MA 418 Module Adapter RJ 11 Pin 1 2 3 4 5 6 Signal Name Send Dat...

Страница 30: ...r tool to lift the Actel Gate Array board location U11 away from the board see dashed circle in the figure below for location of the Actel 5 Remove one of the new Actels labeled 4416 9285E from the pa...

Отзывы: