A. For
local
control operation:
1.
Set to local control:
REMOTE
switch (S2, position 5) UP.
2.
Turn service on:
OFF
switch (S2, position 6) UP.
3.
Install the module into the shelf (see
MOUNTING
, below).
B. For
remote
control operation:
1.
Set to local control:
REMOTE
switch (S2, position 5) UP.
2.
Turn service off:
OFF
switch (S2, position 6) DOWN.
3.
Install the module (see
MOUNTING
, below).
4.
Wait 15 seconds; this loads the parameter settings for the card into the
shelf common module.
5.
Remove the module and set to remote control:
REMOTE
switch
DOWN. Do not turn service on.
6.
Reinstall the module.
7.
Verify the configuration via remote control by issuing a CONFIG?
query. See Section 2.6.2.,
Remote Configuration Codes
, for an
explanation of the CONFIG? response.
8.
Set service on via remote control (ISiCL
SET
command, with “
SRVC =
ON
” in the parameter field). You can now change the operating
parameters for the module using ISiCL commands. For details on using
the Intraplex Simple Command Language (ISiCL) for remote access and
control, consult your multiplexer operation manual.
MOUNTING:
Insert the module into the selected slot in the Intraplex multiplexer.
!!! IMPORTANT:
The module must be inserted so that the white ejector tab is at the
bottom
in a full size (3RU) shelf, or at the
right
in a compact (1RU) shelf.