© Switzerland Gastrofrit AG

Pastacooker error catalog

Error description / display

How to fix

Remarks

1

Error 1

Call up the PT 100 menu

Note the display

Check PT-1000 connection

If, ok, then measure the PT-1000 

ohmic value

OK = about 108 ohms / 20 ° C

NOK = 0 ohms or infinite

2

Machine heats up through unregulated

Check contactor

Check software version

Perform a CPU reset

Reset limiter button

Contactor sticks, contactor has to

be checked and possibly replaced

3

conventional machine heats through 

unregulated

Check thermostat

check contactor

Thermostat misadjusted and not 

adjusted

4

The machine only heats when the red

heating pulse switch is pressed

Replace heating limit switch

Can`t always be replaced

must be bridged

5

No indication on the display

De-energize the device

Electronics defective

Change control

6

Residual current switch / fuse blows out

The heater has a short circuit

Check wiring

burnt heater plug

Phase – Phase oder Phase-

0-wire short circuit

SSR/ Triac has short circuit

7

Conventional machine, power switch

green does not ligh up

Press the limiter button or

replace.

8

Lift motors only run halfway up/down

Replace capacitor 33μF/ 270V 

clean the lift motor

9

Lift motors are moving in the wrong 

direction

Capacitors 33μF/ 270V

double mounted.

Check cable connection of hoist

motor (phases reversed)

Capacitor value cancels

corresponds to the value if no 

capacitor is installed

10

No water supply

Check solenoid valve

Solenoid valve cold water up to 

50ºC

Solenoid valve hot water up to

100ºC

11

Machine leaking

Check PT-1000 seal

Check drain system

Check water supply

Содержание 110135

Страница 1: ...r product was entirely made in Switzerland Your pro duct has been subjected to a long term test Please note that the performance fluctuations safeguards and frequency ranges 50 Hertz or 60 Hertz differ in individual countries Before commissioning check the exact requirements for carefree operation of the device Installation connection and commissioning of the control may only be carried out by per...

Страница 2: ...3 Installation of heating basin additional parts 3 Assembly instructions lift motor 6 Pastacooker error catalog 7 Fault catalog deep fryers 8 Installation description of the fitting box with pan 8 Fittingbox 8 Installation situation components 9 Installation of display box 10 Mounting the bracket on the built in stove 13 Customer service maintenance 14 Built in drawings ...

Страница 3: ...d next to a large heat source sufficient ventilation of the control box must be ensured maximum temperature of the control box 70 C 4 Wird das Gerät neben einer großen Hitzequelle eingebaut ist auf eine genügende Lüftung des Steuerkastens zu achten maximale Temperatur des Steuerkastens 70 C Installation of the heating basin normal case Inlay and silicone seal The heating basin is placed in the cor...

Страница 4: ... on which the lifting mo tor rests must be cleaned of dirt oil splashes insu lation and other objects 1 Please extend the lifting rod neutral conduc tor and brown phase 2 Turn the bushing away from the square tube with a 24 mm open ended spanner 3 Now you can push the lifting rod through the hole in the pan from below Make sure that the offset in the square tube protru des against the pan The wash...

Страница 5: ...SR JP3 1 2 A C a c Schütz JP3 1 2 Leiterplatte Gastro 8 Power 1 3 2 2 3 1 Unternehmens Dokumentation Anschlussschema FittingBox intern SSR für Energieoptimierung Dok Nr ARAN 001 1 Dok Typ Arbeitsanweisung Herausgeber Version Datum Datei Anschlussschema_FittingBox_SSR_Gastro8_Energieopt doc COO Markus Rüsch 0 August 2010 Seite 1 of 1 S1 Thermoswitch L1 L2 L3 N GND Power IN ST1 L1 L2 L3 N GND Power ...

Страница 6: ...n t always be replaced must be bridged 5 No indication on the display De energize the device Electronics defective Change control 6 Residual current switch fuse blows out The heater has a short circuit Check wiring burnt heater plug Phase Phase oder Phase 0 wire short circuit SSR Triac has short circuit 7 Conventional machine power switch green does not ligh up Press the limiter button or replace ...

Страница 7: ...e Elektronics defective Change control 6 Residual current switch fuse blows out The heater has a short circuit Check wiring Burnt heater plug Phase Phase oder Phase 0 conductor short circuit SSR Triac has short circuit 7 Conventional machine power switch green does not light up Press or replace the limiter button 8 Lift motors only run halfway up down Replace capacitor 33μF 270V Clean the lift mot...

Страница 8: ...zerland Gastrofrit AG Installation description of the fitting box with pan Bracket 2 x Welding studs M4 x 8 mm Knurled nut Fittingbox Installation situation components Pan as an example F2 400 Membrane keyboard Built in cover ...

Страница 9: ...splay box 1 4 x Position Welko M4 8 mm symmetrically to the cut 2 Rectangle dimensions Hight 91 mm Width 144 mm 3 Assembly seal Apply seal 4 Assembly Display Assembly of the display box 4x hexagon nut M4 5 close the lid Tighten with a hexagon nut M3 with flange and serrated lockwasher 6 ...

Страница 10: ...and Gastrofrit AG Mounting the bracket on the built in stove Sheet metal for 2 x holes 0 8 mm fastening the bracket Dimensioning Lower edge panel cover to cover 64 5 mm Inner surface fix the cover to the center of the bracket 87 mm ...

Страница 11: ...11 www gastrofrit ch Switzerland Gastrofrit AG Position the hole 0 8 mm symmetrically to the display box Holes Bracket Hexagon nut M4 ...

Страница 12: ...F2 400 780 580 3 TW 300 280 580 3 TW 350 580 3 TW 400 780 580 3 Installation dimensions pans basins The heating basins are placed in the corresponding opening the joint must be sealed with silicone The holes provided for frame assembly can be closed with blind rivets or screws The silicone joint must be checked regularly for leaks in order to avoid the ingress of liquids in the long term ...

Страница 13: ...s Important With every report to the service point please state the type and number of the device inside of the door It is recommended to enter the type and number be low Regular maintenance can extend the life of your Extend the device With a service and maintenance contract you can instruct the manufacturer to check your device every six months You can find more detailed information on the servi...

Страница 14: ...tutzen kurz 750mm beiAblassstutzen normal 2 2 20mm seitlicher Abstand A 3000022 TW 300 350 400 GASTROFRIT Gastrofrit AG Friteusen und Teigwarenkoch Automaten Weiherstr 11a CH 9400 Rorschach A3 8 7 6 5 8 7 6 5 D D C B A F E C B A 4 3 2 4 3 2 1 10 DIN ISO 1302 Änderung Bl Blatt Oberflächen Bearb Gepr Norm Tolerierung ISO 8015 Allg Toleranzen DIN ISO 2786 Tol Schweissen DIN ISO 13920 AE Kl Nr BG Datu...

Страница 15: ...Änd Änd Änd Änd e f a b g c Blatt Art Nr Gastrofrit AG Weiherstrasse 11 CH 9400 Rorschach Änd Datum Name erst am Name Änd h Änd d Allg Toleranzen Schweissen Oberfläche Datum Freigabe Name Benennung Zeichn Nr Gewicht 368 639 160 400 600 95 26 590 390 B B 2xØ8mm für Halterung Steuerbox 150 4 144 91 80 4 R 9 2 128 SCHNITT B B 4x Schweissbolzen M4x8 65 allseitig min 20mm 400 100 40mm für Einbau Steuer...

Страница 16: ... Änd Änd Änd Änd e f a b g c Blatt Art Nr Gastrofrit AG Weiherstrasse 11 CH 9400 Rorschach Änd Datum Name erst am Name Änd h Änd d Allg Toleranzen Schweissen Oberfläche Datum Freigabe Name Benennung Zeichn Nr Gewicht 637 327 342 160 allseitig min 20mm 398 40mm für Einbau Steuerbox laut Zeichnung 100 5 12 629 26 4 65 118 121 407 164 5 351 A A 350 600 95 26 590 340 B B 2xØ8mm für Halterung Steuerbox...

Страница 17: ...iherstrasse 11 CH 9400 Massstab Format Material Datum Änd Änd Änd Änd Änd e f a b g c Blatt Art Nr Gastrofrit AG Weiherstrasse 11 CH 9400 Rorschach Änd Datum Name erst am Name Änd h Änd d Allg Toleranzen Schweissen Oberfläche Datum Freigabe Name Benennung Zeichn Nr Gewicht 531 178 191 802 13 3 allseitig min 20mm 56mm für Einbau Steuerbox laut Zeichnung 480 240 67 00 A A E E 400 600 816 157 00 Ansi...

Страница 18: ...18 www gastrofrit ch Switzerland Gastrofrit AG ...

Страница 19: ...0 2 0 5 0 5 0 2 unbemasste Werkstückkanten DIN ISO 13715 Massstab Format Material Datum Änd Änd Änd Änd Änd e f a b g c Blatt Art Nr Gastrofrit AG Weiherstrasse 11 CH 9400 Rorschach Änd Datum Name erst am Name Änd h Änd d Allg Toleranzen Schweissen Oberfläche Datum Freigabe Name Benennung Zeichn Nr Gewicht 531 178 192 802 13 3 allseitig min 20mm 56mm für Einbau Steuerbox laut Zeichnung 479 50 67 0...

Страница 20: ...0 5 0 2 unbemasste Werkstückkanten DIN ISO 13715 Massstab Format Material Datum Änd Änd Änd Änd Änd e f a b g c Blatt Art Nr Gastrofrit AG Weiherstrasse 11 CH 9400 Rorschach Änd Datum Name erst am Name Änd h Änd d Allg Toleranzen Schweissen Oberfläche Datum Freigabe Name Benennung Zeichn Nr Gewicht 531 178 192 802 619 433 13 3 allseitig min 20mm 56mm für Einbau Steuerbox laut Zeichnung 392 153 32 ...

Страница 21: ...se 11 CH 9400 Massstab Format Material Datum Änd Änd Änd Änd Änd e f a b g c Blatt Art Nr Gastrofrit AG Weiherstrasse 11 CH 9400 Rorschach Änd Datum Name erst am Name Änd h Änd d Allg Toleranzen Schweissen Oberfläche Datum Freigabe Name Benennung Zeichn Nr Gewicht 531 178 191 802 619 433 13 3 allseitig min 20mm 56mm für Einbau Steuerbox laut Zeichnung 30 394 A A E E 400 600 816 160 00 Ansicht ohne...

Страница 22: ...22 www gastrofrit ch Switzerland Gastrofrit AG ...

Страница 23: ...23 www gastrofrit ch Switzerland Gastrofrit AG ...

Страница 24: ...24 www gastrofrit ch Switzerland Gastrofrit AG ...

Отзывы: