5 Technical details
Display-cooler
Model no
GcGW50
Climate classification
0, 1, 2, 3, 4, 6 / N
Foam Agent
Cyclopentan
Volume
49 L
Protection class
1
Voltage
230 V
Frequency
50 Hz
Rated current
1.5 A
Power
175 W
Lamp Power
1 W / 1 W
Energy consumption
~2,7 kWh / 24 h
Refrigerant
R290 (28 g)
Dimensions h × W × D
66 × 48 × 50 cm
net weight
43 kg
All appliance-specific data have been determined by the appliance
manufacturer by means of Europe-wide standardised measuring
methods under laboratory conditions. These are specified in EN62552.
The actual energy consumption of the appliances during use is of
course dependent upon the installation site and user behaviour, and
so may also be higher than the values determined by the appliance
manufacturer under standard conditions.
The expert is familiar with this context and carries out the tests with
special measuring instruments according to the applicable standards.
circuit diagram
E
N
L
5.1 Refrigerant
BEWARE
The appliance contains in the refrigerant circuit the
!
refrigerant propane (R290), a highly environmen-
tally compatible natural gas that is inflammable.
While transporting and installing the appliance ensure
that no parts of the refrigerant circuit are damaged.
Procedure if the refrigerant circuit is damaged:
• avoid open fire and ignition sources at all costs
• ensure that the room in which the appliance is located is well ventilated