12
5.
Nomenclature
GSR-M16-DC/M
Nominal Heating Capacity
M = Monophase , T= Three Phase
M = Monoblock
MODEL
CAPACITY
POWER SUPPLY
GSR-M4-DC/M
4 kW
220~240VAC, 1 Ph , 50Hz
GSR-M6-DC/M
6 kW
220~240VAC, 1 Ph , 50Hz
GSR-M8-DC/M
8 kW
220~240VAC, 1 Ph , 50Hz
GSR-M10-DC/M
10 kW
220~240VAC, 1 Ph , 50Hz
GSR-M12-DC/M
12 kW
220~240VAC, 1 Ph , 50Hz
GSR-M14-DC/M
14 kW
220~240VAC, 1 Ph , 50Hz
GSR-M16-DC/M
16 kW
220~240VAC, 1 Ph , 50Hz
GSR-M10-DC/T
10 kW
380~415VAC, 3 Ph, 50Hz
GSR-M12-DC/T
12 kW
380~415VAC, 3 Ph, 50Hz
GSR-M14-DC/T
14 kW
380~415VAC, 3 Ph, 50Hz
GSR-M16-DC/T
16 kW
380~415VAC, 3 Ph, 50Hz
Operation Range
Mode
Heat Source Side Temperature (°C)
User Side Temperature (°C)
Heating
-25 ~ 35
25 ~ 60
Cooling
10 ~ 48
7 ~ 25
Water Heating
-25 ~ 45
40 ~ 80
Forced Operation Mode
:
this mode is only used for refrigerant recovery and debugging for the unit.
Holiday mode
:
this mode is only available for heating mode. This mode is set to keep indoor temperature or leaving water
temperature in a certain range, so as to prevent water system of the unit from freezing or protect certain indoor articles from
freezing damage. When the outdoor unit stops due to malfunction, the two e-heaters of the unit will run.
Disinfection mode
:
in this mode, the water heating system can be disinfected. When starting up the disinfection function and setting
corresponding time to meet the requirement of disinfection mode, the function will start. After the setting temperature is reached, this
mode will terminate.
Weather-
dependent Operation
:
this mode is only available for space heating or space cooling. In Weather- dependent mode,
the setting value (remote room air temperature or leaving water temperature) is detected and controlled automatically when the
outdoor air temperature is changed.
Quiet mode
:
Silent mode is available in cooling, heating and water heating mode. In silent mode, the outdoor unit will reduce the
running noise via automatic control.
Floor
commissioning
: this function is intended to preheat the floor periodically for the initial use.
Air
removal
of the water
system
: this function is intended to replenish water and remove air in the water
system to make the equipment run at the stabilized water pressure.
Solar water heater:
when the condition for starting the solar water heater is satisfied, the solar heater will start to heat the
circulation water. Then the heated water will go to the water tank and exchange heat with water in it. At any condition, the solar water
heater will be given priority for startup so as for energy conservation.
Other
thermal
:
when the outdoor temperature is lower than the set point for starting other thermal and the unit is under the error
condition and the compressor has stopped for three minutes, the other thermal will start to supply heat or hot water to the room.