High Efficiency

With a COP value up to 5.5, our heat pumps are very efficient when transferring heat from the air to the 

swimming pool water. With the heat pump technology, as much as 80% of cost compared to an electrical 

heater can be saved.

Long Life-Span

The heat exchanger is made of PVC & Titanium tube, which can withstand and prolong exposure to 

swimming pool/pond water.

Easy Control and Operation

The unit is very easy to operate: simply switch it on and set the desired pool water temperature. The system 

includes a micro-computer controller, allowing all operation parameters to be set. Operation status can be 

displayed on the controller with LCD display.

Excellent components

High quality Japanese brand compressor: Mitsubishi, Toshiba, Sanyo compressor with green gas R410A, 

achieving higher performance of heat exchanging.

Durable and reliable Titanium heat exchanger, which can resist chloride ion corrosion in the water; 

hydrophilic fin-tube evaporator, inbuilt threaded pipe, which provides good performance in water skiing and 

anti-defrost.

2.

Safety Precautions

Attention!

It is required to read the Safety precautions in detail before operation. The precautions 

listed below are all-important for safety, please obey without fail.

2.1

General

1) Before install the heat pump, please confirm the local power supply is in accordance with the requirement 

of the heat pump, refer to the Technical data and the Wiring diagram provided in this manual.

2) Connecting the heat pump to a ground wire is necessary, in order to prevent electrical shock caused by 

an unexpected short circuit inside the unit.

3) Please install the electrical protection devices, according to the local regulations.

4) The heat pump must be installed on reliable base or supporting framework.

5) If the heat pump is installed on the floor, its base or supporting framework should be heightened, to avoid 

ingression of accumulated water in rainy season. In snowy areas, it is important to prevent accumulated 

snow from blocking up the air-out. The recommended height is 20cm to 30cm.

6) Install the drainage pipe before fix the heat pump to the ground. There are two drainage hole on the heat 

pump base, which could be connected to the drainage pipe with a pipe arches which contains in spare 

parts.

7) Drain ditch or other facilities should be arranged under the heat pump, to avoid the environment influence 

because of water discharge.

8) Ensure the unit is well ventilated, direction of air exhaust is kept away from windows of neighboring 

buildings, and the exhaust air cannot flow back. Moreover, adequate service clearance should be kept 

around the unit.

9) DO NOT put fingers or sticks into the ventilative fan.

10) The unit should not be installed at places accompanied with oil, inflammable gas, corrosive 

components e.g. sulfur compound, or high-frequency equipment.

11) The heat pump is usually placed next to a house, which gives a directed sound distribution that should 

be considered, so it should take proper action to reduce the noise impact.

Содержание GSR-11-PL

Страница 1: ...INSTALLATION AND USER MANUAL EN 50 70 90 115 125 150 POOL HEAT PUMP GSR 11 PL GSR 13 PL GSR 18 PL GSR 26 PL ...

Страница 2: ...Panel 14 6 1 ON OFF 14 6 2 Working Modes 14 6 3 Time Setting 15 6 4 Water Temperature Setting 15 6 5 Working information 15 6 6 Water flow detection 16 7 Internal Parameters 16 7 1 Controller State Table 16 8 Maintenance and Trouble Shooting 17 9 Manometer Instruction 17 CONTENT 1 ATTENTION Before installing mounting the heat pump please read this user manual carefully Otherwise heat pump may be d...

Страница 3: ... refrigerant within the EVAPORATOR coil absorbs the heat from the outside air becomes a gas The warm gas in the coil passes through the COMPRESSOR concentrating and increasing the heat to form a very hot gas which then passes to the CONDENSER water heat exchanger It is here that the heat exchange occurs as the hot gas gives off heat to the cool swimming pool water circulating through the coil The ...

Страница 4: ... and the Wiring diagram provided in this manual 2 Connecting the heat pump to a ground wire is necessary in order to prevent electrical shock caused by an unexpected short circuit inside the unit 3 Please install the electrical protection devices according to the local regulations 4 The heat pump must be installed on reliable base or supporting framework 5 If the heat pump is installed on the floo...

Страница 5: ...ndenser Titanium in PVC Titanium in PVC Titanium in PVC Titanium in PVC Evaporator Hydrophilic aluminium φ9 52 innergroove tube Hydrophilic aluminium φ9 52 innergroove tube Hydrophilic aluminium φ9 52 innergroove tube Hydrophilic aluminium φ9 52 innergroove tube Fan motor Power Input W 80 80 140 320 Fan Speed RPM 900 900 800 800 Capillary or Expansion Valve Capillary Capillary Capillary Capillary ...

Страница 6: ...5 4 Dimensions GSR11 PL GSR13 PL GSR18 PL GSR 11 PL GSR 13 PL GSR 18 PL A 372 422 422 B 392 452 452 C 650 640 640 D 628 754 754 E 1006 1026 1026 F 260 300 355 G 145 135 122 H 344 415 415 ...

Страница 7: ...6 GSR26 PL GSR 26 PL A 960 B 752 C 691 D 765 E 460 F 122 G 450 ...

Страница 8: ... accompanied with oil Inflammable gas corrosive components e g Sulfur compound or high frequency equipment 7 The unit must be installed on reliable base or framework Weight capacity of framework should be 3 times of the body weight and safeguard measures should be taken to avoid malfunction of fastenings 8 The unit should not be installed at sites with typhoon earthquake hazards Midair installatio...

Страница 9: ...when the flow of the pool pump exceeds the authorized flow through the heat exchanger of the heat pump with 20 5 2 Pool Connection Diagram With the by pass set correctly best performance of the pool heat pump will be made Please see the right diagram for the connection SETTING Valve 1 close slightly Valve 2 open half way Valve 3 open completely ...

Страница 10: ...the valve which connected to water outlet to avoid frost crack 3 If the unit is under off season should cut off power and take the protection cover outside of unit when necessary 4 Before restart the unit which has drained out all the water inside the user is advised to reinstall the unit and adjust program further more need complete check of the system 5 4 NOTS for Anti Freezing in Winter The fil...

Страница 11: ...ction to a general power supply with full earth and neutral or neutral earth systems 3 The power supply cable must be connected to a circuit breaker with at least a 3mm breaking gap Incoming supply must be 220 240V 1 50Hz via a distribution board with fuses 4 If an insulation test is to be carried out in the building please make sure to disconnect the heat pump 5 The communication wire must be STP...

Страница 12: ...11 GSR11 PL GSR13 PL 5 6 Electric Circuit Drawing ...

Страница 13: ...12 GSR18 PL ...

Страница 14: ...13 GSR26 PL ...

Страница 15: ... machine comes to a complete hold Button serves to change the working mode By pressing this button the icon corresponding to the selected mode will appear Automatic heating and cooling The heat pump will maintain the water temperature at the desired value 1 C Heating only heating Heats the water up to the desired value 1 C Cooling mode only cooling Cools the water down to the desired value 1 C 6 1...

Страница 16: ...e fan Third indicate the compressor During the start time delay the corresponding symbol will blink Symbol indicates that the machine is defrosting Symbol indicates that the keyboard is locked To lock or unlock the keyboard press and simultaneously during several seconds 6 3 Time Setting 6 4 Water Temperature Setting 6 5 Working Information Set hours with or Press one time button to confirm The he...

Страница 17: ...tration pump is working Check by pass setting EE7 Memory problem Change PCB EE8 Communication error Check electrical connection between controller and electronic card inside the machine PP1 Probe error Water in Check probe connection PP3 PP10 Probe error evap PP4 PP11 Probe error comp in PP5 Probe error ambiance PP6 PP8 Too much difference between water in and water out Check by pass setting PP7 D...

Страница 18: ...ter Before stopping the heat pump for long time drain out all water in the pipes and shut off the power supply and put it into a shield Full inspection of the system is required before next operation All protective settings in the unit have been set before ex factory Users must not adjust it when the heat pump unit is in use Users should call the installer or the seller every time when there is an...

Страница 19: ...iklik hakkı saklıdır Gassero Isı Teknolojileri Sanayi Limited Şirketi İstanbul Endüstri ve Ticaret Serbest Bölgesi 4 Sokak No 8 34957 Tuzla Istanbul TÜRKİYE Telefon 90 216 394 09 85 86 87 Faks 90 216 394 24 91 www gassero com ...

Отзывы: