background image

3

2

Gas Installation Codes

•  Appliances must be used in accordance with the

 

  installation requirements of your gas supply  

  authority, or the Australian Standard AS 5601.

•  Appliances for use with bottled gas are labelled 

 

  ‘propane gas’.

Clearances

Minimum Clearances from combustible materials 

must be: 

Rear - 350mm    Sides - 300mm    Above - 600mm

Hose & Regulator Safety

The regulator and hose assembly supplied with the 

appliance are suitable for propane gas only.  

A gas regulator adjusted to have an outlet 

pressure of 2.75kPA is supplied for connection to 

the propane gas cylinder. The pressure regulator 

and hose assembly supplied with the appliance 

must be used. Replacement pressure regulators 

and hose assemblies must be those specified by 

the appliance manufacturer. 
When connecting the hose and regulator assembly 

to the gas cylinder, take care to avoid unnecessary 

twisting or kinking of the flexible hose.

After the assembly has been secured, turn on the 

gas and check for leaks by brushing a soap and 

water solution over all connections.
If you are unable to correct the leak by tightening 

the connections, turn off the gas and contact the 

supplier immediately.
Always ensure the appliance is kept away from 

flammable materials and the gas cylinder clear 

of any heat source. When changing over from 

an empty gas cylinder to a full one make sure 

this procedure is carried out in a flame free 

atmosphere.

Gas Cylinder Use & Safety

This is a low pressure appliance and must only be 

used with the hose and regulator supplied. It is 

designed for use with 9Kg propane gas cylinders 

certified to AS 2469.
The cylinder should be filled by a reputable gas 

supplier and visually inspected and re-qualified at 

each filling.

Always keep cylinder in an upright position. 

GENERAL INFORMATION

CONTENTS

Section

Page

General information

2-3

General assembly

4

Lighting procedure

4

Operating procedure

5

Care and maintenance

5

Important safeguards

6

Service and safety

7

Operating instructions

7

Electrical data

7

Assembly instructions

8-10

Natural gas conversion

11

Safe appliance locations

12

 

Side clearances of 300mm must  

 

be maintained to allow adequate  

 

airflow for combustion.

  Rear clearance of 350mm must be maintained

 

 

to avoid overheating surrounding surfaces.

For any queries or assistance call

Customer Service

Australia Only

1300 174 876

Hours of operation: 

Monday to Friday 8.30am - 5.30pm EST

Do not return to place of purchase.

Keep your purchase receipt, this will be 

required to make any claims under the 12 

month warranty.

Содержание P0100 Series

Страница 1: ...n for versatile cooking from cooking pizzas with a delicious wood fired flavour to a beautifully cooked roast dinner Cooks up to 3 pizzas at a time Convenient electronic ignition Cool touch heat resistant handle Includes food safe ceramic pizza stone Powerful 22MJ h stainless steel burner Large viewing window with temperature gauge Easy clean vitreous enamel interior AGA certified Propane gas Cert...

Страница 2: ...lways ensure the appliance is kept away from flammable materials and the gas cylinder clear of any heat source When changing over from an empty gas cylinder to a full one make sure this procedure is carried out in a flame free atmosphere Gas Cylinder Use Safety This is a low pressure appliance and must only be used with the hose and regulator supplied It is designed for use with 9Kg propane gas cy...

Страница 3: ...inder Read carefully before assembling and operating your appliance Location of your Appliance DO NOT use in garages porches sheds breezeways or other enclosed areas Your appliance is to be used OUTDOORS and is not intended to be installed in or on recreational vehicles and or boats and should not be placed on any surface that will burn Do not obstruct the flow of combustion and ventilation air ar...

Страница 4: ...Open the door and ensure that it remains open while lighting the burner 4 With sparking established turn the cylinder valve ON Then push and turn the control knob to HIGH and press the ignitor button 5 If the burner fails to light after several attempts turn off gas supply at cylinder and inspect for obstructions to gas flow If re ignition is necessary while the appliance is still hot you must wai...

Страница 5: ...ck Spiders and small insects occasionally spin webs or make nests in the burner tubes during warehousing and transit These webs can lead to a gas flow obstruction which could result in a fire in and around the burner tubes This type of fire is known as FLASH BACK and can cause serious damage to your appliance and create an unsafe operating condition for the user Although an obstructed burner tube ...

Страница 6: ...en using this product including the following When storing the Product gently wind the Cord around the Cord Wrap if provided otherwise loosely coil the cord Avoid wrapping the Cord around the Product Avoid contacting moving parts Keep hands hair and clothing well away from the Product while it is in operation DO NOT operate or place any part of this Product on or near any hot surfaces such as a ga...

Страница 7: ...r to replace the Cord or a special Cord is required Note This transformer must only be used with the light in your pizza oven OPERATING INSTRUCTIONS 1 Plug the Power Cord into a Power Outlet and turn ON To avoid damage to the Power cord make sure it is kept away from the Product when in use 2 When unattended we recommend you make sure the Product is turned OFF and DISCONNECTED from the Power Suppl...

Страница 8: ...h Note Remove any transit protection material STEP 1 Lay the Pizza Oven on it s back and attach the washers and rubber feet by using 4 M5 screws 30mm long STEP 2 Stand the Pizza Oven on it s feet and attach the chimney to the body by using 3 M4 screws 8mm long Then attach the control knob ...

Страница 9: ...4 Position the wire racks ensuring the folded down tabs locate into the holes of the front of the rack supports Locate the ceramic stone into the bottom rack and position it at the rear of the appliance STEP 5 Attach the hose connection thread 1 4 B S P and tighten securely with a spanner Leak test using a soapy water solution ...

Страница 10: ... tighten by screwing it clockwise OPTIONAL If you have an oven stand attach the transformer onto the back panel using 4 M4 screws 12mm long and nuts with the plug down then connect the end of the electrical wire from the oven to the outlet of the transformer and tighten by screwing it clockwise ...

Страница 11: ...hall not exceed 3 metres in length The internal diameter of the hose must not be less than 10mm 2 Check with local and state plumbing and heating codes regarding sizing of the gas lines 3 All gas pipe connections must be sealed with a gas pipe compound resistant to Natural Gas 4 Installation of a drip leg if required in the gas supply line must conform to AS5601 5 When checking for gas leaks do no...

Страница 12: ...artial enclosure that includes an overhead cover and no more than two walls see Example 2 3 Within a partial enclosure that includes an overhead cover and more than two walls the following will apply at least 25 of the total wall area is completely open and at least 30 of the remaining wall area is open and unrestricted see Example 4 5 In the case of balconies at least 20 of the total wall area sh...

Отзывы: