Screw the coupling nut of regulator into the cylinder valve outlet.
Q.C.C. CYLINDER CONNECTION DEVICE
3
7. The hose assembly should be located out of pathways
where people may trip over it. The hose must be
protected from contact with hot or sharp surfaces
both during use and while in storage. The hose
assembly should be visually inspected prior to
each use of the heater. If excessive abrasion or wear
is evident, or the hose is cut, it must be replaced
prior to operating the heater. The replacement hose
assembly may be obtained from the distributor.
8.
DO NOT
use any pressure regulator or hose
assembly other than those supplied with the
appliance. Replacement pressure regulator and hose
assembly must be those specified. Replacement
parts may be obtained from the distributor.
9. Installation and use of this heater must conform with
New Zealand Standard 5601 “Gas Installations”
10. This heater is designed to operate with a standard
9Kg LPG cylinder with Approved Cylinder Connection.
11. The valve outlet must be maintained in good
condition. When the cylinder is not in use, be sure to
cover it with a dust cap. A leak test should be
performed with soapy water whenever connecting
a new cylinder.
NEVER
use a match to test for leaks.
12. The LPG cylinder must be turned off whenever the
heater is not in use. When the heater is to be stored
indoors, the LPG cylinder and the heater must be
disconnected and the cylinder stored in accordance
with the Standard for Storage and Handling of
Liquefied Gases.
13. The area heater has been designed with several
safety features which include a tip over switch.
Any modification to the heater not described in the
installation instructions may compromise the safety of
this appliance. Special concern is as follows:
(1)
DO NOT
bypass thermocouple safety burner;
(2)
DO NOT
operate heater without the guard;
Clothing or other flammable materials should not be hung
from the heater, or placed on or near the heater. The area
above the burner may be extremely hot. Direct contact
with these metal surfaces should be avoided in order to
prevent burns or clothing ignition.
Q.C.C. CYLINDER CONNECTION DEVICE
Type of Gas
LPG/ULPG
Consumption
40 MJ/h
Operating Pressure
2.75 kPa
Injector Size
1.9mm
Heater specifications can be found on the data label.
Storage of an appliance indoors with the
cylinder attached is only permitted if the size
of the cylinder complies with AS/NZS 1596;
otherwise cylinders must be stored outdoors in
a well ventilated area.
The guards are fitted to this appliance to
reduce the risk of fire or injury from burns and
no part of it should be removed.
This appliance must be protected from
exposure to rain.
Screw the coupling nut of regulator into the cylinder valve outlet.