Screw the coupling nut of regulator into the cylinder valve outlet.
Q.C.C. CYLINDER CONNECTION DEVICE
2
3
7. The hose assembly should be properly located out of
pathways where people may trip over it. The hose
must be protected from contact with hot or sharp
surfaces both during use and while in storage. The
hose assembly should be visually inspected prior to
each use of the appliance. If excessive abrasion or
wear is evident, or the hose is cut, it must be
replaced prior to operating the appliance. The
replacement hose assembly may be obtained from
the distributor.
8.
DO NOT
use any pressure regulator or hose
assembly other than those supplied with the
appliance. Replacement pressure regulator and hose
assembly must be those specified. Replacement parts
may be obtained from the distributor.
9. Installation and use of this appliance must conform
with New Zealand Standard 5261 “Gas Installations”.
10. This appliance is designed to operate with a standard
9Kg LPG cylinder with Approved Cylinder Connection.
11. The valve outlet must be maintained in good
condition. When the cylinder is not in use, be sure to
cover it with a dust cap. A leak test should be
performed with soapy water whenever connecting
a new cylinder.
NEVER
use a match to test for leaks.
12. The LPG cylinder must be turned off whenever the
appliance is not in use. When the appliance is to be
stored indoors, the LPG cylinder and the appliance
must be disconnected and the cylinder stored in
accordance with LPG Dangerous Goods Regulations.
13. Store the appliance upright in an area sheltered away
from weather conditions. The use of a cover is
recommended.
14. The appliance has been designed with several safety
features which include a tip over switch and a flame
safeguard system which means if the pilot goes out
the unit will automatically turn off.
REGULATOR SAFETY FEATURE
All QCC regulators (the part that attaches to the gas
cylinder to regulate the flow of gas) have a safety feature
included that restricts gas flow in the event of a gas leak.
You can inadvertently activate this safety feature without
having a gas leak. This typically occurs when you turn
on the gas using the appliance control knob before you
turn on the gas cylinder valve. If the gas regulator safety
feature activates, the appliance will operate with reduced
output as gas flow is restricted.
These steps should be taken first to reset the gas
regulator safety device:
1. Turn gas cylinder valve off.
2. Turn appliance off.
3. Disconnect the regulator from the gas cylinder.
4. Wait 30 seconds.
5. Reconnect the regulator to the gas cylinder.
6. Leak test the connection using a soapy water solution.
Ensure no bubbles appear before proceeding.
7. Slowly open the gas cylinder valve all the way. Do not
put excessive force on the valve at the full open
position, to avoid damaging the valve.
8. Light the appliance as per the instructions provided.
Any modification to the appliance not described in th e
installation instructions may compromise the safety of
this appliance. Special concern is as follows:
(1)
DO NOT
bypass thermocouple safety burner;
(2)
DO NOT
operate appliance without the guards;
Clothing or other flammable materials should not be hung
from the appliance, or placed on or near the appliance.
The area above the burner may be extremely hot.
Direct contact with these metal surfaces should be
avoided in order to prevent burns or clothing ignition.
Q.C.C. CYLINDER CONNECTION DEVICE
Type of Gas
General Product LPG
Consumption
39.6 MJ/h
Operating Pressure
2.75 kPa
Injector Size
1.7 mm
Appliance specifications can be found on the data label.