Part 4 - General venting
Figure 4.3 Bracket securing
Warning
Use only the provided self tapping screws, these screws have the correct length. Using screws with a longer
length will damage the actual PP vent.
Cut-able installation
These instructions must be followed together with the instructions in the manual that is
supplied with the roof or wall terminal. That manual gives special instructions for applications, pressure drops,
maintenance and mounting of the complete vent system. This product is a cut-able concentric vent & air section
that must be installed as part of the concentric
vent and air system. It’s not allowed to build a complete system
with cut-able sections only. Before installing the cut-able concentric vent section, read and follow the instructions
of the manuals that are supplied with the terminal and the (concentric) vent air system.
Installation
1.
Measure the gap between the two parts between which the cut-able concentric vent section must be installed.
2.
Cut the concentric vent section with regard to the instructions on the adhesive on the product see also figure
4.4.
Figure 4.4 Vent section cutting
20