background image

www.desatech.com

7

113048-01F

Figure 3 - Ventilation Air from Outdoors

Figure 2 - Ventilation Air from Inside 

Building

Or 

Remove 

Door into 

Adjoining 

Room, 

Option 3

Ventilation Grills 

Into Adjoining Room,

Option 2

12"

12"

Ventilation

Grills

into Adjoining

Room, 

Option 1

Outlet

Air

Ventilated

Attic 

Outlet

Air

Inlet

Air

Inlet Air

Ventilated 

Crawl Space

To 

Crawl

Space

To Attic

AIR FOR COMBUSTION 

AND VENTILATION

Continued 

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or 

ducts. You must provide two permanent openings: 

one within 12" of the ceiling and one within 12" 

of the floor. Connect these items directly to the 

outdoors or spaces open to the outdoors. These 

spaces include attics and crawl spaces. Follow the 

National Fuel Gas Code, ANSI Z223.1/NFPA 54, 

Section 5.3, Air for Combustion and Ventilation 

for 

required size of ventilation grills or ducts.

IMPORTANT:

 

Do not provide openings for inlet 

or outlet air into attic if attic has a thermostat-

controlled power vent. Heated air entering the attic 

will activate the power vent.

INSTALLATION

NOTICE: This heater is intended 

for  use  as  supplemental  heat. 

Use this heater along with your 

primary heating system. Do not 

install  this  heater  as  your  pri-

mary heat source. If you have a 

central heating system, you may 

run system’s circulating blower 

while using heater. This will help 

circulate the heat throughout the 

house. In the event of a power 

outage, you can use this heater 

as your primary heat source.

 WARNING: A qualified ser-

vice person must install heater. 

Follow all local codes.

CHECK GAS TYPE

Use only the correct type of gas (natural or pro-

pane/LP). If your gas supply is not the correct gas 

type, do not install heater. Call dealer where you 

bought heater for proper type heater.

  WARNING:  This  appliance 

is equipped for (natural or pro-

pane/LP) gas. Field conversion 

is not permitted.

INSTALLATION ITEMS

Before installing heater, make sure you have the 

items listed below.
•  for propane/LP gas, external regulator (supplied 

by installer)

•  piping (check local codes)
•  sealant (resistant to propane/LP gas)
•  equipment shutoff valve *
•  ground joint union
•  sediment trap
•  tee joint
•  pipe wrench
•  for natural gas, test gauge connection*
* A CSA design-certified equipment shutoff valve 

with 1/8" NPT tap is an acceptable alternative to 

test gauge connection. The optional CSA design-

certified equipment shutoff valve can be purchased 

from your dealer. See 

Accessorie

s, page 23.

Содержание GMN18

Страница 1: ...t use any phone in your building Immediately call your gas supplier from a neigh bor s phone Follow the gas supplier s instruc tions If you cannot reach your gas supplier call the re department Instal...

Страница 2: ...g plate This appliance is not convert ible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer State of Massachusetts The installation must be made...

Страница 3: ...his heater WARNING Any change to this heater or its controls can be dangerous WARNING Donotuseablow er insert heat exchanger insert orotheraccessorynotapproved for use with this heater Due to high tem...

Страница 4: ...and to replace any part of the control system and any gas control which has been under water 12 Turn off and let cool before servicing Only a quali ed service person should service and repair heater...

Страница 5: ...e air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusual...

Страница 6: ...used _______________ Btu Hr maximum the space can support _______________Btu Hr actual amount of Btu Hr used Example 51 200 Btu Hr maximum the space can support 60 000 Btu Hr actual amount of Btu Hr u...

Страница 7: ...or use as supplemental heat Use this heater along with your primary heating system Do not install this heater as your pri mary heat source If you have a centralheatingsystem youmay run system s circul...

Страница 8: ...y cause mildew to form from too much moisture See Air for Combustion and Ventilation page 5 If high hu midity is experienced a dehumidi er may be used to help lower the water vapor content in the air...

Страница 9: ...re hold for the mounting bracket Marking Screw Locations 1 Tape mounting bracket to wall where heater will be located Make sure mounting bracket is level WARNING Maintain mini mumclearancesshowninFigu...

Страница 10: ...e Wall anchors mounting screws and spacers are in hardware package The hardware package is provided with heater Attaching To Wall Stud Method For attaching mounting bracket to wall studs 1 Drill holes...

Страница 11: ...er heater regulator damage could occur CAUTION For propane LP gas never connect heater di rectly to the propane LP supply This heater requires an external regulator not supplied Install theexternalreg...

Страница 12: ...ve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 15 IMPORTANT Install an equipment shutoff valve in an accessible loc...

Страница 13: ...pply piping system by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 3 Check all joints f...

Страница 14: ...ol Models OPERATING HEATER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a re or explosion may result causing property damage per sonal injury or loss o...

Страница 15: ...control used on these models differs from standard thermostats Standard thermostats simply turn on and off the burner The thermostat used on this heater senses the room temperature At times the room m...

Страница 16: ...me BURNER FLAME PATTERN FOR BLUE FLAME HEATERS WARNING If yellow tipping occurs your heater could pro duce increased levels of carbon monoxide NOTICE Do not mistake orange ames with yellow tipping Dir...

Страница 17: ...ions on the can you could damage the pilot assembly 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes 2 Inspect burner pilot for dust and dirt 3 Blow air acros...

Страница 18: ...ion 4 Air in gas lines when installed 5 Depleted gas supply pro pane LP gas only 6 ODS pilot is clogged 7 Gas regulator setting is not correct OBSERVED PROBLEM When ignitor button is pressed there is...

Страница 19: ...gas company 1 Contact local natural or pro pane LP gas company 2 Clean burner see Cleaning and Maintenance page 17 or replace burner ori ce 1 Clean burner see Cleaning and Maintenance page 17 or repla...

Страница 20: ...nto white powder residue 1 Plaque damaged 2 Inlet gas pressure is too low 3 Control knob set between locked positions REMEDY 1 Check burner for dirt and debris If found clean burner see Cleaning and M...

Страница 21: ...t above 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement above 1 Not enough combustion ven tilation air OBSERVED PROBLEM Heater produces a c...

Страница 22: ...mum 10 5 Minimum 4 Heater Weight 20 lb Shipping Weight 25 lb GMP26 AND GMP26T Propane LP Gas 26 000 Btu Hr GMP26 has variable settings Piezo Ignition Pressure Regulator Setting 8 W C Inlet Gas Pressur...

Страница 23: ...t 1 866 672 6040 for referral information When calling DESA Heating Products have ready model number of your heater the replacement part number ACCESSORIES Purchase these heater accessories from your...

Страница 24: ...www desatech com 113048 01F 24 ILLUSTRATED PARTS BREAKDOWN MODELS GMP16 GMP16T GMN18 GMN18T GMP26 GMP26T GMN30 AND GMN30T 14 15 8 5 6 7 4 3 1 2 16 10 9 11 12 13 17 See Pages 26 27...

Страница 25: ...2 01 Control Rod Assembly 1 10 098325 01 Roll Pin 1 11 098354 03 Control Knob 1 12 099415 18 Gas Regulator Propane LP 1 099415 19 Gas Regulator Natural 1 13 104819 02 Regulator Bracket 1 14 098522 24...

Страница 26: ...A 1 103353 04 Tubing Valve to Plaque A 1 11 103352 04 Tubing Valve to Plaque B 1 103353 05 Tubing Valve to Plaque B 1 12 103353 06 Tubing Valve to Plaque C 1 13 107660 01 Inlet Tube 1 107660 03 Inlet...

Страница 27: ...ctor Plaque A or C 1 2 099056 25 Injector Plaque A or C 1 2 7 099056 01 Injector Plaque B 1 099056 02 Injector Plaque B 1 If replacing ODS pilot and your model is pre 2002 your part number will be 103...

Страница 28: ...www desatech com 113048 01F 28 ILLUSTRATED PARTS BREAKDOWN MODELS GMP20BT GMN20BT GMP30BT AND GMN30BT 2 3 5 6 8 9 10 10 11 12 13 14 16 18 19 4 7 1 15 17 20...

Страница 29: ...y 1 9 098271 09 Ignitor Cable 1 10 098249 01 Nut 2 11 110803 01 ODS Pilot Assembly NG 1 110803 02 ODS Pilot Assembly LP 1 12 103446 02 Burner 1 103447 06 Burner 1 13 099387 03 Pilot Tubing 1 14 103845...

Страница 30: ...__ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________...

Страница 31: ...__ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________...

Страница 32: ...this product and or DESAHeating Products who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty The heater MUST be installed by a qu...

Отзывы: