OBSERVED PROBLEM

ODS/pilot  lights  but  flame 

goes out when control knob is 

released

Burner  does  not  light  after 

ODS/pilot is lit

Delayed ignition of burner(s)

Burner backfiring during com-

bustion

REMEDY

1. Press in control knob fully

2. After ODS/pilot lights, keep con-

trol knob pressed in 30 seconds

3. Wait one minute for safety in-

terlock system to reset. Repeat 

ignition operation

4. Fully open equipment shutoff 

valve

5. Hand tighten until snug, then 

tighten 1/4 turn more

6. A)  Contact  local  natural  or 

propane/LP gas company

  B)  Clean  ODS/pilot  (see 

Cleaning  and  Maintenance

page 17) or replace ODS/pilot 

assembly

7. Replace pilot assembly

8. Replace control valve

1. Clean  burner  (see 

Cleaning 

and Maintenance

, page 17) or 

replace burner orifice

2. Contact local natural or pro-

pane/LP gas company

1. Contact local natural or pro-

pane/LP gas company

2. Clean  burner  (see 

Cleaning 

and Maintenance

, page 17) or 

replace burner orifice

1. Clean  burner  (see 

Cleaning 

and Maintenance

, page 17) or 

replace burner orifice

2. Replace burner

3. Replace gas regulator

POSSIBLE CAUSE

1. Control knob not fully pressed 

in

2. Control knob not pressed in 

long enough

3. Safety  interlock  system  has 

been  triggered  (thermostat 

models only)

4. Equipment shutoff valve not 

fully open

5. Thermocouple  connection 

loose at control valve 

6. Pilot flame not touching ther-

mocouple, which allows ther-

mocouple to cool, causing pilot 

flame to go out. This problem 

could be caused by one or both 

of the following:

  A) Low gas pressure

  B) Dirty or partially clogged 

ODS/pilot 

7. Thermocouple damaged

8. Control valve damaged

1. Burner orifice is clogged

2. Inlet gas pressure is too low

1. Manifold pressure is too low

2. Burner orifice is clogged

1. Burner orifice is clogged or 

damaged

2. Burner damaged

3. Gas regulator defective

TROUBLESHOOTING

Continued

Содержание GMN18

Страница 1: ...t use any phone in your building Immediately call your gas supplier from a neigh bor s phone Follow the gas supplier s instruc tions If you cannot reach your gas supplier call the re department Instal...

Страница 2: ...g plate This appliance is not convert ible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer State of Massachusetts The installation must be made...

Страница 3: ...his heater WARNING Any change to this heater or its controls can be dangerous WARNING Donotuseablow er insert heat exchanger insert orotheraccessorynotapproved for use with this heater Due to high tem...

Страница 4: ...and to replace any part of the control system and any gas control which has been under water 12 Turn off and let cool before servicing Only a quali ed service person should service and repair heater...

Страница 5: ...e air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusual...

Страница 6: ...used _______________ Btu Hr maximum the space can support _______________Btu Hr actual amount of Btu Hr used Example 51 200 Btu Hr maximum the space can support 60 000 Btu Hr actual amount of Btu Hr u...

Страница 7: ...or use as supplemental heat Use this heater along with your primary heating system Do not install this heater as your pri mary heat source If you have a centralheatingsystem youmay run system s circul...

Страница 8: ...y cause mildew to form from too much moisture See Air for Combustion and Ventilation page 5 If high hu midity is experienced a dehumidi er may be used to help lower the water vapor content in the air...

Страница 9: ...re hold for the mounting bracket Marking Screw Locations 1 Tape mounting bracket to wall where heater will be located Make sure mounting bracket is level WARNING Maintain mini mumclearancesshowninFigu...

Страница 10: ...e Wall anchors mounting screws and spacers are in hardware package The hardware package is provided with heater Attaching To Wall Stud Method For attaching mounting bracket to wall studs 1 Drill holes...

Страница 11: ...er heater regulator damage could occur CAUTION For propane LP gas never connect heater di rectly to the propane LP supply This heater requires an external regulator not supplied Install theexternalreg...

Страница 12: ...ve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 15 IMPORTANT Install an equipment shutoff valve in an accessible loc...

Страница 13: ...pply piping system by either opening propane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air 3 Check all joints f...

Страница 14: ...ol Models OPERATING HEATER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a re or explosion may result causing property damage per sonal injury or loss o...

Страница 15: ...control used on these models differs from standard thermostats Standard thermostats simply turn on and off the burner The thermostat used on this heater senses the room temperature At times the room m...

Страница 16: ...me BURNER FLAME PATTERN FOR BLUE FLAME HEATERS WARNING If yellow tipping occurs your heater could pro duce increased levels of carbon monoxide NOTICE Do not mistake orange ames with yellow tipping Dir...

Страница 17: ...ions on the can you could damage the pilot assembly 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes 2 Inspect burner pilot for dust and dirt 3 Blow air acros...

Страница 18: ...ion 4 Air in gas lines when installed 5 Depleted gas supply pro pane LP gas only 6 ODS pilot is clogged 7 Gas regulator setting is not correct OBSERVED PROBLEM When ignitor button is pressed there is...

Страница 19: ...gas company 1 Contact local natural or pro pane LP gas company 2 Clean burner see Cleaning and Maintenance page 17 or replace burner ori ce 1 Clean burner see Cleaning and Maintenance page 17 or repla...

Страница 20: ...nto white powder residue 1 Plaque damaged 2 Inlet gas pressure is too low 3 Control knob set between locked positions REMEDY 1 Check burner for dirt and debris If found clean burner see Cleaning and M...

Страница 21: ...t above 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement above 1 Not enough combustion ven tilation air OBSERVED PROBLEM Heater produces a c...

Страница 22: ...mum 10 5 Minimum 4 Heater Weight 20 lb Shipping Weight 25 lb GMP26 AND GMP26T Propane LP Gas 26 000 Btu Hr GMP26 has variable settings Piezo Ignition Pressure Regulator Setting 8 W C Inlet Gas Pressur...

Страница 23: ...t 1 866 672 6040 for referral information When calling DESA Heating Products have ready model number of your heater the replacement part number ACCESSORIES Purchase these heater accessories from your...

Страница 24: ...www desatech com 113048 01F 24 ILLUSTRATED PARTS BREAKDOWN MODELS GMP16 GMP16T GMN18 GMN18T GMP26 GMP26T GMN30 AND GMN30T 14 15 8 5 6 7 4 3 1 2 16 10 9 11 12 13 17 See Pages 26 27...

Страница 25: ...2 01 Control Rod Assembly 1 10 098325 01 Roll Pin 1 11 098354 03 Control Knob 1 12 099415 18 Gas Regulator Propane LP 1 099415 19 Gas Regulator Natural 1 13 104819 02 Regulator Bracket 1 14 098522 24...

Страница 26: ...A 1 103353 04 Tubing Valve to Plaque A 1 11 103352 04 Tubing Valve to Plaque B 1 103353 05 Tubing Valve to Plaque B 1 12 103353 06 Tubing Valve to Plaque C 1 13 107660 01 Inlet Tube 1 107660 03 Inlet...

Страница 27: ...ctor Plaque A or C 1 2 099056 25 Injector Plaque A or C 1 2 7 099056 01 Injector Plaque B 1 099056 02 Injector Plaque B 1 If replacing ODS pilot and your model is pre 2002 your part number will be 103...

Страница 28: ...www desatech com 113048 01F 28 ILLUSTRATED PARTS BREAKDOWN MODELS GMP20BT GMN20BT GMP30BT AND GMN30BT 2 3 5 6 8 9 10 10 11 12 13 14 16 18 19 4 7 1 15 17 20...

Страница 29: ...y 1 9 098271 09 Ignitor Cable 1 10 098249 01 Nut 2 11 110803 01 ODS Pilot Assembly NG 1 110803 02 ODS Pilot Assembly LP 1 12 103446 02 Burner 1 103447 06 Burner 1 13 099387 03 Pilot Tubing 1 14 103845...

Страница 30: ...__ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________...

Страница 31: ...__ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________...

Страница 32: ...this product and or DESAHeating Products who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty The heater MUST be installed by a qu...

Отзывы: