Installation and Operation Manual
Argos WA - Pressure Regulating Valve
MI-44
Elaborado
Verificado / Aprovado
CSQ
Data
Revisão
Página
JJ
GN
JM
03/09/18
01
6 de 20
2.3.2 – AVAILABLE CONNECTIONS
ND
FLANGE ASME
B16.5
1”
150#/300#
2”
150#/300#
3”
150#/300#
4”
150#/300#
2.3.3 – TEMPERATURE LIMITS
Operating temperature: -20°C a 60°C
Ambient temperature: -20°C a 60°C
The temperature limits informed at this manual or in any applicable standard must not be exceeded under any
circumstances, at risk of damage the equipment, safety of installation and safety of people involved in the operation.
2.3.4 – FLOW COEFICIENT
DN
KG
1”
400
2”
1140
3”
2800
4”
4900
2.3.5 – VALVE WEIGHT (Kg)
DN
SINGLE
ACTIVE/MONITOR
150#
300#
150#
300#
1”
7
10
13
16
2”
11
14
29
35
3”
21
15
-
-
4”
32
38
-
-