TROUBLESHOOTING 21
125
Faults
Possible cause
Action
Engine has too little power
Ignition system defective
–
Ignition coil - check the secondary wind-
ing.
–
Check the spark plug connector.
–
Check the stator winding of the alterna-
tor.
The engine dies during the trip
Lack of fuel
–
Refuel. (
Fuse
1
blown
–
Change the fuses of individual electrical
power consumers. (
Fuse
4
blown
–
Change the fuses of individual electrical
power consumers. (
Engine overheats
Coolant level low in cooling sys-
tem
–
Check the cooling system for leaks.
–
Check the coolant level. (
Insufficient airflow
–
Switch off engine when stationary.
Radiator fins very dirty
–
Clean radiator fins.
Foam formation in cooling system
–
Drain the coolant.
–
Refill the coolant.
Bent radiator hose
–
Change the radiator hose.
Thermostat defective
–
Check the thermostat.
Guideline
Opening temperature: 70 °C (158 °F)
Malfunction indicator lamp lights
up or flashes
Error in the electronic fuel injec-
tion
–
Check wiring for damage and electrical
plug-in connectors for corrosion and dam-
age.
–
Read out the fault memory using the GAS-
GAS Motorcycles diagnostics tool.
High oil consumption
Engine vent hose bent
–
Route the vent hose without bends or
replace it if necessary.
Engine oil level too high
–
Check the engine oil level. (
Engine oil too thin (low viscosity)
–
Change the engine oil and oil filter, clean
the oil screen.
Piston and cylinder worn
–
Measure the piston/cylinder mounting
clearance.
12-V battery discharged
The 12-V battery is not being
charged by the alternator
–
Check the charging voltage.
–
Check the stator winding of the alterna-
tor.
Unwanted electrical power con-
sumer
–
Check the open-circuit current.
Values in combination instrument
deleted (time, stop watch, lap
times)
The combination instrument bat-
tery is empty
–
Change combination instrument battery.
(
The high beam, low beam, tail
light, position light, and license
plate lamp are not working
Fuse
2
blown
–
Change the fuses of individual electrical
power consumers. (
The horn, brake light, turn signal,
and radiator fan (optional) are not
working
Fuse
3
blown
–
Change the fuses of individual electrical
power consumers. (
Содержание EC 350F
Страница 1: ...OWNER S MANUAL 2021 EC 350F Art no 3215013en ...
Страница 2: ......
Страница 40: ...10 SERVICE SCHEDULE 38 One time interval Periodic interval ...
Страница 138: ...23 TECHNICAL DATA 136 Screw in fitting cooling system M24x1 5 18 Nm 13 3 lbf ft Loctite 243 ...
Страница 150: ... 3215013en 3215013en 10 2020 Stallhofnerstraße 3 5230 Mattighofen Austria http www gasgas com ...