SERVICE WORK ON THE ENGINE 18
125
S04503-10
Main work
–
Pull the EFI control unit
1
upward off the rubber plugs and hang to
the side.
–
Remove protection cap
2
of the diagnostics connector.
S04406-12
–
Put throttle grip
3
into full throttle position and secure.
S04504-10
–
Plug in wake-up connector
4
for priming the oil pump to the diag-
nostics connector
5
.
The combination instrument lighting is activated.
–
Wait for at least five seconds.
–
Release the fixing means from the throttle grip.
The oil pump is timed.
Info
The oil pump is actuated at various speeds.
The procedure is clearly audible.
–
Wait until you can no longer hear the oil pump operating.
–
Disconnect the wake-up connector from the diagnostics connector.