background image

AIR CONDITIONER FEATURES

(CONTINUED)

TO SELECT THE

OPERATING MODE:

Press the Mode
button.

TO USE THE ENERGY

SAVER FEATURE:

SLEEP FEATURE:

Press Sleep
button

7

In this mode the selected temperature will increase
(cooling) or decrease (heating) by 2 F/1 (or 2) C 30
minutes after the mode is selected.The temperature
will then increase (cooling) or decrease (heating) by
another 2 F/1(or 2) C after an additional 30 minutes.
This new temperature will be maintained for 6 hours
before it returns to the originally selected temperature.
This ends the Sleep mode and the unit will continue to
operate as originally programmed. The Sleep mode
program can be cancelled at any time during operation
by again pressing the Sleep button.

O

O

O

O

NOTE:

Each time you press the button, a mode is selected
in

 goes from Auto, Cool, Dry 

 will be illuminated

and remain on once the mode is selected.

NOTE:

To operate on Auto feature:

In this mode, the fan speed cannot be adjusted, it

room temperature.

To operate on Fan Only:

Use this function only when cooling is not desired,
such as for room air circulation or to exhaust stale
air (on some models). (Remember to open the vent
during this function, but keep it closed during
cooling for maximum cooling efficiency.) You can

During this function, the display will show the actual
room temperature, not the set temperature as in the
cooling mode.

will continue to run for 3 minutes after the compressor
shuts off The fan then cycles on for 2 minutes at 10
minute intervals until the room temperature is above
the set temperature, at which time the compressor

NOTE:

To operate on Dry mode:

In this mode, the air conditioner will generally
operate in the form of a dehumidifier. Since the
conditioned space is a closed or sealed area, some
degree of cooling will continue.

When you set the air conditioner in AUTO mode, it will

the temperature is not  adjusted.

#

#

To choose the operating mode, press the Mode button.

the following:

and Fan.

The indicator light next to the button

temperature you have selected and the room temperature.

only models), or fan only operation depending on what

The air conditioner will control the room temperature
automatically around the temperature point set by you.

starts automatically at a speed determined by the

choose whatever fan speed you prefer.

In Fan only mode

Press E nergy 

 button

Saver

#

#

#

#

Mode 

Mode 

Auto

Auto

Mode 

Mode 

Auto

Auto

automatically select cooling, heating (except in cooling

This function is available on COOL mode ?? The  fan

.

.

#

turns back on and Cooling Starts.

Содержание 043-5488-8

Страница 1: ...Before using your air conditioner please read this manual carefully and keep it for future reference WINDOW AIR CONDITIONER 043 5488 8 6 000BTU...

Страница 2: ...intended for use by young children or infirm persons without supervision Young children should be supervised to ensure that they do not play with the air conditioner If the power cord is to be replac...

Страница 3: ...ing or pulling out the power plug Do not operate with wet hands or in damp environment Do not allow water to run into electric parts Do not use the socket if it is loose or damaged Do not use the powe...

Страница 4: ...he circuit breaker Isolate supply by taking the power plug out and contact a qualified service technician 3 appliance or accident Appearance may be deteriorated due to change of product color or scrat...

Страница 5: ...llowing 1 Plug in the Air Conditioner click as the RESET button pops out a light on the plug head Do not use this device to turn the unit on or off Always make sure the RESET button is pushed in for c...

Страница 6: ...educed outside of these operating temperatures pinging or swishing sounds being moved by the fan 18 43 C T1 Environment 21 52 C T3 Environment 17 32 C T3 Environment NOTE This air conditioner is desig...

Страница 7: ...e desired temperature is seen on the If you want the display to read the actual room temperature see To Operate on Fan Only section NOTE TO ADJUST FAN SPEED Press to select appropriate fan speed 6 NOT...

Страница 8: ...s function but keep it closed during cooling for maximum cooling efficiency You can During this function the display will show the actual room temperature not the set temperature as in the cooling mod...

Страница 9: ...will cancel the Auto Start Stop timed program press the illuminates It indicates the Auto Stop program is initiated Auto timer settings the room temperature O O unit and plug it back in If error repe...

Страница 10: ...ompressor and possible circuit breaker tripping The fan will continue to run during this time To convert from one to the other press and hold the Up and Down Temp Timer buttons at the same time for 3...

Страница 11: ...not inside a building or garage NOTE Carton Installation Instructions Save and these during winter or when not in use Fig 1 INNER INTERIOR WALL Wooden Windows WINDOW SILL Packaging Top Rail 2 Sash Loc...

Страница 12: ...nto the rails on the cabinet 11 C Once the panel has been installed on the side of the cabinet make sure it sits securely inside the frame channel by making slight adjustments Slide the top and bottom...

Страница 13: ...k between the frame exten locking screws through the frame lock and into the sill NOTE To prevent window sill from splitting screws 4 Fig 5 Fig 6 sill Fig 5 Carefully close the window behind the top w...

Страница 14: ...ire sill Fasten with nails or screws Removing AC From Window 13 Turn AC off and disconnect power cord Remove sash seal from between windows and unscrew safety lock Remove screws installed through fram...

Страница 15: ...unit without the air filter Be sure to unplug the air conditioner to prevent be dusted with an oil free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing de...

Страница 16: ...rs for better air distribution Clear blockage in front of unit Compressor shut off by changing modes Wait approximately 3 minutes and listen for compressor to restart when set in the COOL mode Air con...

Страница 17: ...xcessively humid days Remote Sensing Deactivating Prematurely Remote control not located within range Place remote control within 20 feet 180 radius of the front of the unit Remote control signal obst...

Страница 18: ...FEATURES OF REMOTE CONTROL 17...

Страница 19: ...18 AAAX2...

Страница 20: ...19 and...

Страница 21: ...There seems to be two spaces in between words remove one 20...

Страница 22: ...21...

Страница 23: ...22...

Страница 24: ...23...

Страница 25: ...24 a result from of items 6 Routine maintenance and cleaning necessary to keep the good working condition...

Страница 26: ...25 Return Policy Garrison...

Отзывы: