background image

S14 & PS14P (PoE) Convenient Switches   

Installation and User Guide  

 
 48

www  GarrettCom  com

.

.

 

12VDC 

  24VDC 

  -48VDC

 

 

 

The Internal 12V DC (8 – 15V DC) has a built-in terminal block for +, -, ground. The 9V 

DC jack is also present. Detail information about the 12 VDC, the 24V DC and the –48V 

DC is provided in the Technical Specifications Section 1.1.  

 

The various models of Direct DC power type and extended ambient temperature 

power supplies are numerous and your choice needs to be called out on your order.

   

Note: 

When connected to a - 48 V centralized dc source these products are to be installed 

only in Restricted Access Areas (dedicated equipment rooms, electrical closets or the like).

 

Содержание PS14H-48VDC

Страница 1: ...arters GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 Phone 510 438 9071 Fax 510 438 9072 Website http www GarrettCom com email support garrettcom com Magnum S14 Convenient Switch PS14P Power S...

Страница 2: ...art 84 00100Z Rev D Trademarks GarrettCom is a registered trademark and Magnum Dymec DynaStar Personal Switch Link Loss Learn S Ring Convenient Switch and Converter Switch are trademarks of GarrettCom...

Страница 3: ...l and void If problems are experienced with Magnum S14 PS14P 10 100 Mb s Convenient Switches consult Section 5 Troubleshooting of this User Guide Copyright 2005 GarrettCom Inc All rights reserved No p...

Страница 4: ...use interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules...

Страница 5: ...supply circuit to the product 3 This product shall be provided with a maximum 5A DC Listed fuse or circuit breaker in the supply circuit when connected to a 48V centralized source 4 The external power...

Страница 6: ...ettCom com Contacting GarrettCom Inc Please use the mailing address phone and fax numbers and email address listed below GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 Phone 510 438 9071 Fax 51...

Страница 7: ...12 2 2 Product Description 13 2 2 1 Magnum PS14P 4 port PoE Power Source Switch 18 2 3 Magnum PS14P S14 Series with four RJ 45 Copper ports 24 2 4 Frame Buffering and Latency 25 2 5 Features and Benef...

Страница 8: ...7 1 Power Requirement for PS14P PoE Power Source Switch 53 3 8 Connecting Twisted Pair RJ 45 ports 54 3 8 1 Connecting Twisted Pair RJ 45 CAT 3 or CAT 5 Unshielded or Shielded 55 3 8 2 Connections to...

Страница 9: ...ORMATION 68 Revisions Rev D 11 09 updated DIN Rail mount photo pg 46 Rev C 08 08 revised S14 weight specifications on page 4 01 06 Updated the PS14P POE Power Source Switch Rev B 05 05 Added Magnum PS...

Страница 10: ...Mbps Data Rate 100Mbps When a port is operating at 10 Mbps Data Rate 10 Mbps Network Standards 100Mb Ethernet IEEE 802 3u 100BASE TX IEEE 802 1p 10 Mb Ethernet IEEE 802 3 10BASE T Power Over Ethernet...

Страница 11: ...max Processing type Store and Forward non blocking Auto learning 2K address table Address buffer age out time 300 sec Packet buffers memory 128KB dynamically shared on all domains Non blocking switch...

Страница 12: ...167 F 40 C to 75 C Short term per IEC Type tests S14P PS14P 40 F to 185 F 40 C to 85 C Long term per independent agency tests UL 40 F to 167 F 40 C to 75 C Short term per IEC Type tests Storage Tempe...

Страница 13: ...closure Robust sheet metal Steel Dimensions Switch unit Height x Width x Depth S14 S14H S14P PS14P 3 5 in H x 3 0 in W x 1 0 in D 8 9 cm x 7 6 cm x 2 5 cm Weight all S14 models 8 6 oz 243g power suppl...

Страница 14: ...cts shall be provided with a Listed 5A DC fuse in the supply circuit UL listed class II Power Supply AC External Power input 8 15 V DC jack is 2 5mm center ve with 6ft cord Input 120vac at 60 Hz for d...

Страница 15: ...C built in screw terminal block for ground The 12V DC jack is also present 12V DC internal range of 8 0 to 15V DC 24V DC internal range of 18 to 36V DC 48V DC internal range of 36 to 60V DC t Power Co...

Страница 16: ...PUT PS14P POE unit only PoE available on all four RJ 45 ports via Ethernet twisted pair cabling on port pins using spare pairs 4 5 7 8 not the data pair 1 2 3 6 802 3af Power Consumption 61 6 watts ma...

Страница 17: ...ng power PS14P 10 100 100Mbps OFF 10 Mbps LK ACT Steady ON for LINK with no traffic blinking indicates port is transmitting receiving F H ON full duplex OFF half duplex Mounting option for S14 Family...

Страница 18: ...ss A NEBS L3 and ETSI compliant H P models IEEE P1613 Env Std for Electric Power Substations P model NEMA TS 2 and TEES for traffic control equipment P model designed for UL 2043 above the ceiling ins...

Страница 19: ...24VDC model but includes DIN RAIL MC2 option S14H 48VDC Same as S14H 24VDC model except for 48VDC power input S14P Pd Pi Premium rated four 10 100 RJ 45 ports Switch for un controlled outdoor env Int...

Страница 20: ...5 Ethernet ports support Power Source PoE as per the IEEE 802 3ad standard Includes integral 48V DC terminal block for power unit NOTE If you want a heavy duty Industrial power supply that plugs into...

Страница 21: ...s damage prior to installing this product notify the carrier immediately of any damage which you believe occurred during shipment or delivery Inspect the contents of this package for any signs of dama...

Страница 22: ...nt Switches covers the full range of application environments with regular office Hardened factory floor and Premium rated outdoor versions Extra features for heavy duty and extended temperature opera...

Страница 23: ...Magnum S14 Rear view one RJ 45 port on rear side 8 15V DC GarrettCom S14 Left Side View Fig 2 2b GarrettCom Magnum S14 Convenient Switch LA1 LA3 F H LA2 PWR 10 100 PORT 1 PORT 2 P O R T 3 P O R T 4 L...

Страница 24: ...as shown above in Fig 2 2c is a hardened unit designed for factory floor and other industrial applications The S14H models are built with high grade components and use special thermal techniques and...

Страница 25: ...W W G arrettCom Com 10 100 LK AC T LK ACT 10 100 10 100 LK A C T POWER Magnum S14H Hardened Convenient Switch GarrettCom Magnum S14H Hardened Convenient Switch Fig 2 2c Magnum S14H Front view three R...

Страница 26: ...S14P Premium Rated Convenient Switch The red label Magnum S14P as shown in Fig 2 2e is a premium rated unit suitable for temperature un controlled outdoor applications Specially designed with premium...

Страница 27: ...first Industrial PoE switch called the Magnum PS14P Convenient Switch Designed and developed with premium grade extended temperature components premium rated PS14P switches are suitable for use in sh...

Страница 28: ...S14P switches are Power Sourcing Equipment PSE and are fully compatible with Powered Devices PD e g wireless access points IP phones that comply with the IEEE 802 3af PoE standard The PS14P switch por...

Страница 29: ...t option in industrial commercial outdoor and military applications the Magnum PS14P is enabling the efficient deployment of reliable VoIP and wireless access networking devices to increase the effici...

Страница 30: ...points and WLAN Mobility system VOIP phones Remote Security Camera SNTP Clock Factory floor and building control monitoring Temperature Smoke Heat and other environmental sensors Fire alarms Security...

Страница 31: ...se choice for all PoE device applications The PS14P is a very important convenient source to meet all PoE requirements with a multi choice of options The Magnum PS14P PoE Switch provides edge access E...

Страница 32: ...sumption to provide 13 15w power on each port to the PoE unit The heavy duty Din rail mounted 48V DC power supply can be purchased using this URL http www lanstore com ps htm Note The 8 15vdc option i...

Страница 33: ...the S14 Series convenient switch support auto cross MDIX and perform the auto cross in the auto negotiation mode only Dual LEDs indicating the operating status of ports are mounted on the top as well...

Страница 34: ...inspected before forwarding can occur This technique ensures that all forwarded frames are of a valid length and have the correct CRC i e are good packets This eliminates the propagation of bad packet...

Страница 35: ...is available for good packets when the traffic load is greatest When the Switch detects that its free buffer queue space is low the Switch sends industry standard full duplex only PAUSE packets out to...

Страница 36: ...lex ports in order to stop incoming traffic The latency the time the frame spends in the Switch before it is sent along or forwarded to its destination of the S14 Series PS14P PoE Convenient Switches...

Страница 37: ...mpact package that fits right into the site PS14P Sleek 4 port 10 100 Power Source Switch for PoE devices The compact and robust PS14P PoE acts as a Power plug for all the PoE devices e g CCTV camera...

Страница 38: ...m any angle Each S14 Series PS14P Convenient Switch is equipped with two sets front and side of LEDs to provide status information when viewed at any angle or mounting arrangement rack mount DIN Rail...

Страница 39: ...ower may increase availability or be convenient to move the unit from a test lab out to the factory floor DC Power input for PoE Power Source Switch PS14P The 802 3af PoE standard PS14P power source s...

Страница 40: ...rts to a LAN quickly and cost effectively The edge of the network connectivity product makes challenging industrial applications easier more economical and more reliable The compact Magnum S14 series...

Страница 41: ...m Magnum S14 Convenient Switch GarrettCom Magnum S14 Convenient Switch LA1 LA3 F H LA2 PWR 10 100 PORT 1 PO RT 2 PO R T 3 P O R T 4 LK ACT 10 100 9VDC 1AMP 3 2 1 PORT 4 PORT 1 PORT 2 PORT 3 W W W G ar...

Страница 42: ...ent switches provide this solution very efficiently and economically Various features included MDIX plug n play Din Rail mountings and dual LEDs make this compact and convenient switch a very effectiv...

Страница 43: ...RT 2 P OR T 3 P O RT 4 L K AC T 10 100 9VDC 1AMP 3 2 1 PORT 4 PORT 1 PORT 2 PORT 3 W W W G arrettC om C om 10 100 LK AC T LK ACT 10 10 0 10 100 LK A C T POW ER GarrettCom Magnum S14 Convenient Switch...

Страница 44: ...Example 3 S14Ps The Magnum S14Ps fit very well in high temperature locations control rooms experiencing a need to scale their LAN quickly and cost effectively With its half full duplex switching capa...

Страница 45: ...100 L K A C T LK AC T 1 0 1 0 0 10 100 L K A C T POWER Magnum S14P Premium Rated Convenient Switch and Workstations 100Mb Servers 100 and Workstations 100Mb Servers 100 and Workstations 100Mb Servers...

Страница 46: ...cation where the expansion of their factory network is being done to extend their capacity and make it more secure through CCTV cameras which monitor the day to day manufacturing process The blue toot...

Страница 47: ...C PORT PORT PORT PORT WWW GarrettCo 1 0 L K L K 1 0 1 0 L K P O W GarrettCom Magnum S14 Convenient Switch GarrettCom Magnum S14 Convenient Switch L A L A F H L A P W 10 10 0 P O R P O R P O R P O R L...

Страница 48: ...Magnum PS14P PoE with its power Source Switch capability easily meets the demand to provide power through its RJ 45 cable and allows for a very neat Network setup The Magnum PS14P POE is enabling the...

Страница 49: ...a to PoE devices e g PoE Clock VOIP phone and wireless access point 48vdc power IBM IBM Router Router GarrettCo Magnum S14 Convenient Switch LA 1 LA 3 F H LA 2 PW R 10 100 P O P O P O P O L K 1 0 9 V...

Страница 50: ...tch Unit All the S14 Series PS14P PoE Switches operate in transparent half and full duplex mode The store and forward switch easily take care of the network traffic and can be used as a useful economi...

Страница 51: ...ion is dependent upon the physical layout of the Ethernet network and associated cabling Make sure the unit is installed in a location that is easily accessible to an AC power outlet or power strip an...

Страница 52: ...nvenient Switches along with Media Converter units are mounted with their RJ 45 ports and DC power jacks in the back with either fiber or BNC cable in the front Any mix of the Convenient Switches Medi...

Страница 53: ...are another option available for Rack Mounting the mix match of 10Mbps and 100Mbps Media Converters and the S14 Series PS14P POE Switches together in a 19 rack mount tray These models comes with built...

Страница 54: ...Mbps FT14 s and 100Mb 14E Media Converters each with their power input plugged into the built in common AC power supply in the rear area of the tray PS units that come with the MC s are not used Metal...

Страница 55: ...l mounting in an enclosure having DIN Rails The metal DIN Rail mounting hardware is optional and needs to be ordered as a separate item e g Model DIN RAIL MC2 It comes with four screws to attach the b...

Страница 56: ...extended temperature Hd version is used for heavy duty and industrial applications up to 55 C ambient The 12V DC power input has a plug of 2 5mm center ve with 6 ft cord All the AC power supply design...

Страница 57: ...the 12 VDC the 24V DC and the 48V DC is provided in the Technical Specifications Section 1 1 The various models of Direct DC power type and extended ambient temperature power supplies are numerous an...

Страница 58: ...re attachment of the power leads Three models support a range of power input types The three model choices are for use with 12VDC 24VDC or 48VDC power DC power input may be chosen for high availabilit...

Страница 59: ...com DC Power Terminals floating GND Terminal for earth or ground wire connection to the S14H chassis Input Voltage 8 15V DC 12V DC 18 36V DC 24V DC 36 60V DC 48V DC Input current 0 8 amp 12V DC 0 4 a...

Страница 60: ...the Direct DC power terminal block on the Magnum S14H hardened media converter as shown in Figure above The DC terminal block on the Magnum S14H is located on the left side of the unit and is equipped...

Страница 61: ...d GND is optional it connects to the S14H chassis Ensure that each lead is securely tightened from the top as shown here NOTE Always use a voltmeter to measure the voltage of the incoming power supply...

Страница 62: ...attached The device will not function as PoE Switch while powered up via 12VDC power but as a normal non PoE Switch POWER OUTPUT PoE available on all four RJ 45 ports via Ethernet twisted pair cabling...

Страница 63: ...may be used In either case the maximum distance for unshielded twisted pair cabling is 100 meters 328 ft Media IEEE Standard Connector Twisted Pair CAT 3 or 5 10BASE T RJ 45 Twisted Pair CAT 5 100BASE...

Страница 64: ...o the RJ 45 connector of the port Note that even though the connector is shielded either unshielded or shielded cables and wiring may be used 2 Connect the other end of the cable to the corresponding...

Страница 65: ...NICs Network Interface Cards which support Auto Negotiation and the Fast Link Pulse FLP coding for the 100BASE TX signaling system When connecting a NIC to the S14 Sereis it may be necessary to reloa...

Страница 66: ...ports are full duplex and auto sensing for speed See section 2 2 When the connected device is 10 Mbps the S14s obeys all the rules of 10 Mbps Ethernet configurations The 10 Mbps users share a 10 Mbps...

Страница 67: ...raining them to one port and relieving the rest of the network from processing them A packet whose destination address is on another port segment will be forwarded to the appropriate port and will not...

Страница 68: ...ses To reset the address buffer cycle power down and up 4 2 Auto cross MDIX Auto negotiation and Speed sensing The RJ 45 ports support auto cross MDI or MDIX in the auto negotiation mode according to...

Страница 69: ...products which do not have auto negotiation and which go to the default state accordingly The Magnum Switch advertises its capability for 10 or 100 Mbps speed and F H duplex mode and the device at th...

Страница 70: ...ffic blinking for activity per port LINK will turn off in the event connectivity is lost between the ends of the twisted pair segment or a loss of power occurs in the unit or remote device The Link po...

Страница 71: ...he operation is also straightforward and is discussed in Section 4 Should problems develop during installation or operation this section is intended to help locate identify and correct these types of...

Страница 72: ...during installation About 90 of network downtime can be attributed to wiring and connector problems 3 Make sure that an AC power cord is properly attached to each Magnum S14 Series PS14P PoE unit Be c...

Страница 73: ...vide the following information 1 A complete description of the problem including the following points a The nature and duration of the problem b Situations when the problem occurs c The components inv...

Страница 74: ...3 Return Material Authorization RMA Procedure All returns for repair must be accompanied by a Return Material Authorization RMA number To obtain an RMA number please use this URL https rma garrettcom...

Страница 75: ...ausing the return cannot be duplicated by GarrettCom the unit will be returned as No Problem Found GarrettCom reserves the right to charge for the testing of non defective units under warranty Testing...

Страница 76: ...king material This material may cause electro static shock damage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the shipping container 3 GarrettCom is not r...

Страница 77: ...be defective at no charge other than shipping and handling provided that the product is returned pre paid to GarrettCom This warranty will not be effective if in the opinion of GarrettCom the product...

Отзывы: