Magnum 700X Mini-Concentrators Installation and User Guide (05/98)
GARRETT
29
Figure 3.12.2e: Local Isolation with Bridge Port Module
3. Bridge Transparency:
The BPMs are transparent to both the user and the
application software.
4. LINK and Traffic Status:
The Magnum BPM-TP and BPM-FST indicate link
integrity with an LED. This LINK LED is normally lit. An unlit LINK LED indicates
a broken cable or loss of power at some point in the segment. All BPMs have FWD-I
and FWD-X status LEDs. The FWD-I LED flashes when packets are forwarded into
the local segment. The FWD-X LED flashes when packets are forwarded out of the
local segment.
5. Self-test Diagnostics:
A BPM requires about 15 seconds upon power-up before
bridging services are available. During this time, the BPM performs an internal self-
test.
4.3
Powering the Magnum 700X Mini-Concentrator
The Magnum 700X incorporates an internal universal power supply, and has a female
IEC connector for the AC power cord at the right-rear. A six foot 115 vac power cord is supplied
with each unit. (Except units being shipped from the GCI factory outside the United States and
Canada will not include a 115 vac power cord.)
The Magnum 700X supports installation environments where the AC voltage is from
90 to 260 volts with a power input frequency between 47 and 63 Hz, and will consume no more
than a maximum of 40 watts. The power connector is located on the back of the unit. In order to
eu