background image

Magnum P62-Series Hardened Switches                               Installation and User Guide (05/05)

 

 

 

15 

www  GarrettCom  com

.

.

 

connector will indicate if it is single-mode.  Otherwise it is a multi-mode port.  Each 100Mbps 

fiber port performs as a switched port and as a traffic domain, providing a high bandwidth 

backbone connection that supports long (up to 20km single-mode, or 40km special “long-reach”) 

fiber cable distances for installation versatility.  A fiber port of a P62F is shown here, 

On Magnum P62-Series units, there are three LED’s 

for each of the RJ-45 switched ports. The F/H indicates full-

duplex when ON or half-duplex when OFF.  The (LK/ACT) 

LED is steady ON to indicate LINK, and blinking to indicate 

transmitting / receiving.  The 10/100 LED is ON for 100Mbps 

and OFF for 10 Mbps (when LINK is made).  For fiber ports, 

the LEDs are the same except there is no F/H LED because 

10Mb is not possible.   

There must be a device connected to the Magnum 

P62-Series unit via a cable.  A proper link (LK light) must be made between both devices at each 

end of the cable in order for each LINK LED to provide a valid indication of operating 

conditions. 

2.4 

Frame Buffering and Latency 

 

The Magnum P62-Series Hardened Switch is a store-and-forward switch.  Each frame 

(or packet) is loaded into the Switch’s memory and inspected before forwarding can occur. This 

technique ensures that all forwarded frames are of a valid length and have the correct CRC, (i.e., 

are good packets).  This eliminates the propagation of bad packets, enabling all of the available 

bandwidth to be used for valid information.  

 

While other switching technologies such as "cut-through" or "express" impose minimal 

frame latency, they will also permit bad frames to propagate out to the Ethernet segments 

connected.  The "cut-through" technique permits collision fragment frames, which are a result of 

late collisions, to be forwarded to add to the network traffic.  Since there is no way to filter frames 

with a bad CRC (the entire frame must be present in order for CRC to be calculated), the result of 

indiscriminate cut-through forwarding is greater traffic congestion, especially at peak activity.  

Since collisions and bad packets are more likely when traffic is heavy, the result of store-and-

forward operation is that more bandwidth is available for good packets when the traffic load is 

greatest.  

To minimize the possibility of dropping frames on congested ports, each Magnum P62-

Series Hardened Switch dynamically allocates buffer space from an 1MB memory pool, ensuring 

that heavily used ports receive very large buffer space for packet storage.  (Many other switches 

Содержание Magnum mP62-5V -1M1SSC

Страница 1: ...5 00 USD www GarrettCom com Magnum P62 Series P62F and managed mP62 models Hardened Ethernet Switches Installation and User Guide...

Страница 2: ...Manager patent pending and Link Loss Learn patent pending are trademarks and Personal Hub is a registered trademark of GarrettCom Inc Important The Magnum P62 Series Hardened Ethernet Switches contain...

Страница 3: ...adiate frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and fo...

Страница 4: ...100 and 2 100Mb fiber ports managed and unmanaged models all fiber types Mixed Media Fiber Hub 16 port Stackable 10 100 auto sensing AC and DC power Dual Speed 8 port and 16 port Stackables 10 100 au...

Страница 5: ...wist Pair RJ 45 CAT 3 or CAT 5 Unshielded or Shield 23 3 2 2 Connecting Fiber Optic SC type Snap In 24 3 2 3 Connecting Fiber Optic ST type Snap In Optional 24 3 2 4 Connecting Single Mode Fiber Optic...

Страница 6: ...70VDC to 20 60VDC Rev G 03 03 This revision adds the DIN RAIL mounting options UL requirement for DC Rev F 11 02 This revision adds the Managed mP62 models Rev E 06 02 Changed Altitude spec and added...

Страница 7: ...880 pps max Processing type Store and Forward Auto learning 4K address table 16K on P62F shared for all ports Packet buffers 256KB dynamically shared on all domains Latency not including packet time 1...

Страница 8: ...and 10 100 speed each inde pendently auto negotiating on P62F models S W controlled on mP62 models Fiber Ports 1 and 8 The switched fiber ports 1 8 are fixed at full duplex only 100Mb speed Mechanica...

Страница 9: ...ales GarrettCom com for details Agency Approvals UL Listed UL 60950 cUL CB CE Low Volt Dir Electro Magnetic Comp IEEE P1613 Class 2 Environmental Standard for Electric Power Subs See also Note for Pow...

Страница 10: ...that filters and forwards data moving between the ports The internal switch has 16K nodes address table and 1MB packet buffers DC power input 20 60VDC auto ranging Steel case acts as a heat sink Rated...

Страница 11: ...e ports Software and buffers same as mP62 AC 2MSC Dc power input 20 60VDC auto ranging Magnum mP62 1MISSC Same as mP62 2MSC except one fiber port is 20km single mode SC No PSX unit required Magnum mP6...

Страница 12: ...tion and User Guide 1 Product Registration Card Optional if AC power 1 PSX A Power Source Extended Temp unit 1 6 ft long AC Power chord for PSX A Unit only Optional PSX T 125 or 250VDC 1 PSX T Power S...

Страница 13: ...provide the switching speed and the reliability to smoothly support multiple workgroups at 100Mbps or 10Mbps speed The optional fiber ports are normally configured and tested with Magnum P62 units in...

Страница 14: ...her bandwidth and longer distances on fiber All the LEDs are mounted on the top cover to conveniently indicate operating status of all ports There is a power on PWR indicator and a SELF TEST self test...

Страница 15: ...Magnum mP62 5V mP62 5V with the PSX A AC model The Managed mP62 model is equipped with industry standard network management and utility software operating features to make this Switch suitable to dep...

Страница 16: ...max of 75 C which is 5 C more than the P62F product ratings of 70 C Equipped with high thermal dissipation features patent pending power supply flexibility management MNS mP software capability and a...

Страница 17: ...mail support GarrettCom com for further information 2 2 4 Connecting the Console Terminal to Magnum mP62 Management Use a DB 9 null modem cable to connect the Magnum mP62 Console Port the RS 232 port...

Страница 18: ...and can be order from the factory along with the unit NOTE for Power Substations In support of the IEEE 1613 Class 2 standard GCI advises that for substation applications the serial RJ 45console port...

Страница 19: ...and forward switch Each frame or packet is loaded into the Switch s memory and inspected before forwarding can occur This technique ensures that all forwarded frames are of a valid length and have the...

Страница 20: ...ces to temporarily stop sending traffic which allows a traffic catch up to occur without dropping packets Then normal packet buffering and processing resumes This flow control sequence occurs in a sma...

Страница 21: ...ng in any situation As the units are normally vertical for wall or pedestal mounting top surface viewing is most convenient Installation is Plug n Play operation is transparent to software The Magnum...

Страница 22: ...witch serves this requirement economically and efficiently The six full and half duplex switched ports make the required setup simple for collection of traffic data The uncontrolled outdoor temperatur...

Страница 23: ...ide an exceptional Ethernet product Figure 2 6 2 Three P62F connects together to provide 10 Mbps and100Mbps network with Fast Ethernet backbone In this example the extended temperature rated P62F take...

Страница 24: ...features provide a very economical and efficient solution to this requirement The advanced Link Loss Learn feature will provide a very secure and effective solution in this particular kind of environm...

Страница 25: ...for high reliability and AC power for convenience in out of the way locations Locate the P62 Series unit near any AC power or any 20 60VDC three wire GND power source for DC models that is within the...

Страница 26: ...es measurement information for the PSX unit mounted on top if present and for the Magnum P62 Series unit 3 35 8 5 1 44 3 7 1 64 4 2 2 20 60 VDC TX 0 7A MAX RX 1F POWER SELF TEST LK ACT 10 100 www Garr...

Страница 27: ...le mode 9 125 microns cabling should be used Fiber cabling supports much longer cable distances and higher bandwidth than copper wiring Media IEEE Standard Connector Twisted Pair CAT 3 or 5 10BASE T R...

Страница 28: ...pe Snap In The following procedure applies to installations using SC type fiber connectors This procedure applies to ports using multi mode SC fiber connectors 1 Before connecting the fiber optic cabl...

Страница 29: ...the parameters necessary to compute the power budget To calculate the power budget of different fiber media installations using Magnum products the following equations should be used OPB Optical Power...

Страница 30: ...eady ON It is OFF if there is no traffic or if 10 Mbps traffic 3 3 Powering the Magnum P62 Series Hardened Switch 3 3 1 Power P62F and mP62 models for 48V and 24V DC pwr input Each Magnum Model P62 Se...

Страница 31: ...rement use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located within 6 inches of the terminal block 3 3 2 Power the P62 5V models w Ext AC Powe...

Страница 32: ...nded temperatures to be accommodated The PSX T also includes reverse polarity protection to prevent damage in case the unit is accidentally hooked up backwards The DC power output cord comes with a mi...

Страница 33: ...nection to earthing wiring 8 Use only with Listed 10 A circuit breaker provided in building installation 9 Complies with FDA radiation performance standards 21 CFR subchapter J or equivalent 10 Fasten...

Страница 34: ...on a DIN RAIL track order the optional bracket Model DIN RAIL P62 and use the DIN Rail mounting bracket procedure as illustrated in the picture below See also the GarrettCom web site at http garrettc...

Страница 35: ...plex and auto sensing for speed See section 2 2 When the connected device is 10 Mbps P62s obey all the rules of 10 Mbps Ethernet configurations The 10 Mbps users share a 10 Mbps traffic domain and can...

Страница 36: ...rks They are self learning so that as nodes are added or removed or moved from one segment to another the P62 Series automatically keeps up with node locations An address aging algorithm causes least...

Страница 37: ...media converters etc Please note that there can be conditions with managed switches where the switch manager fixes the port settings via software and the result of the auto negotiation is changed in t...

Страница 38: ...tion Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable 2 Check the cables and connectors to ensure that they have be...

Страница 39: ...personal computers workstations terminals and printers plus the various network media types being used 4 A record of changes that have been made to your network configuration prior to the occurrence...

Страница 40: ...t in Styrofoam popcorn type packing material This material may cause electro static shock damage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the shipping...

Отзывы: