GarrettCom Magnum DX940 Скачать руководство пользователя страница 2

 

 

Declarations 

 

DOCUMENT NOTICE 

 

Copyright 

Copyright  2010  by GarrettCom Inc. Printed in the US. All rights reserved. 
 
This manual may not be reproduced or disclosed in whole or in part by any means without the written 
consent of GarrettCom. DynaStar is a trademark of GarrettCom Inc. All other trademarks mentioned in 
this document are the property of their respective owners. 
 
This  document  has  been  prepared  to  assist  users  of  equipment  manufactured  by  GarrettCom  and 
changes  are  made  periodically  to  the  information  in  this  manual.  Such  changes  are  published  in 

Software  Release  Notices.  If  you  have  recently  upgraded  your  software,  carefully  note  those  areas 
where  new  commands  or  procedures have  been  added.  The  material  contained  in  this  manual  is 
supplied  without  any  warranty  of  any  kind. GarrettCom  therefore assumes no  responsibility  and  shall 
incur no liability arising from the supplying or use of this document or the material contained in it. 

Rights 

Except  as set  forth  in  the  Software  License  Agreement,  GarrettCom  makes no  representation  that 
software  programs  and practices described  herein  will not infringe on  existing or  future  patent  rights, 
copyrights, trademarks, trade secrets or other proprietary rights of third parties and GarrettCom makes 
no  warranties  of  any  kind,  either  express  or  implied,  and  expressly  disclaims  any such  warranties, 
including but not limited to any  implied warranties of merchantability or fitness for a particular purpose 

and any warranties of non- infringement. The descriptions contained herein do not imply the granting of 
licenses  to  make,  use,  sell,  license  or otherwise  transfer  GarrettCom  products described  herein. 
GarrettCom disclaims responsibility for errors which may appear in this document, and it reserves the 
right,  in  its sole discretion and  without notice, to  make  substitutions  and  modifications  in  the  products 
and practices described in this document. 

Part Number Information 

Part Number: 84-00187Z  

Last Update: July 2010 

 

Содержание Magnum DX940

Страница 1: ...Magnum DX940 Configurable Industrial Router Installation Guide GarrettCom Inc 47823 W estinghouse Drive Fremont CA 94539 USA Phone 510 438 9071 Fax 510 438 9072 5 00 USD...

Страница 2: ...ying or use of this document or the material contained in it Rights Except as set forth in the Software License Agreement GarrettCom makes no representation that software programs and practices descri...

Страница 3: ...N LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES EXCEPT WARRANTIES OF TITLE INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE LIMITATION OF LIAB...

Страница 4: ...aterial Authorization RMA from GarrettCom An RMA can be obtained by contacting Sales at 510 438 9071 Equipment accepted for credit not involving a GarrettCom error shall be subject to all the terms of...

Страница 5: ...s de Class A prescrites dans la norme sur le materiel brouilleur Appareils Num riques NMB 003 dict e par le ministre des Communications This product meets the applicable Industry Canada technical spec...

Страница 6: ...nt tre coordonn es par un repr sentant d sign par le fournisseur L entreprise de t l communications peut demander l utilisateur de d brancher un appareil la suite de r parations ou de modifications ef...

Страница 7: ...NG GARRETTCOM Page 7 CONTACTING GARRETTCOM Website www garrettcom com By Mail GarrettCom Inc 47823 Westinghouse Drive Fremont CA 94539 USA Telephone 510 438 9071 Fax 510 438 9072 Email support garrett...

Страница 8: ...seful information related to the text immediately following the alert Notes provide supplemental information or provide a point of emphasis Cautions warn you of the risk of poor system performance or...

Страница 9: ...ent of this or any other GarrettCom manual please feel free to contact us via email with any problems or helpful information All enquiries will be responded to with a correction or whatever resolution...

Страница 10: ...ss interface can be added as well 1 2 Configuration The following sections describe the features and requirements of the DX940 1 2 1 Connectivity The DX940 is equipped with Optional 1 DDS or T1 E1 WAN...

Страница 11: ...and optional serial ports S1 to S4 1 2 2 Power and Ground The DX940 can be ordered with a high 90 250 VAC or VDC or Low 24 48 VDC voltage power supply The connection point for the power supply is loca...

Страница 12: ...X940 is indicated by LEDs located near the physical ports on the front of the DX940 as illustrated in Figure 1 1 and a bank of LEDs on the top of the chassis as illustrated in Figure 1 3 Figure 1 3 To...

Страница 13: ...ts labeled S1 S2 S3 and S4 1 2 4 Mounting Options There are three mounting options for the DX940 19 rack mount see Mounting in a 19 Rail System Panel mount see Mounting on a Panel DIN Rail mount see M...

Страница 14: ...Physical Specifications Height 1 75 inches 4 45 cm Width 9 5 inches 24 13 cm Depth 9 0 inches 22 86 cm Weight 5 0 lbs 2 3 kg 1 3 2 Environmental The environmental specifications of the DX940 are defin...

Страница 15: ...MagField EN61000 6 5 EN61000 4 11 VDI EN61000 4 2 ESD EN61000 4 12 Oscillatory EN61000 4 3 RF EN61000 4 16 CCM EN61000 4 4 EFT EN61000 4 17 Ripple EN61000 4 5 SURGE EN61000 4 29 VDI Safety UL60950 EN6...

Страница 16: ...LC connector Serial S1 through S4 DB9 female Connection to serial async devices Configurable to 300 600 1200 2400 4800 9600 and 19 2 28 8 33 6 38 4 57 6 115 2 230 4 Kbps Power Connection Terminal blo...

Страница 17: ...ough the port E1 E6 Ethernet Ports Green Port is connected to an active Ethernet device Off Port is down Flashing Data is passing through the port Console Green Connected to an active local terminal O...

Страница 18: ...h the DDS connection Table 1 7 RJ48 DDS Pin out Pin Signal 1 Tx Data Ring 2 Tx Data Tip 3 not used 4 not used 5 not used 6 not used 7 Rx Data Tip 8 Rx Data Ring 1 4 2 RJ48 T1 E1 Connection Table 1 8 d...

Страница 19: ...ernet capable devices Table 1 9 RJ45 Pin out Pin Signal 1 Tx 2 Tx 3 Rx 4 not used 5 not used 6 Rx 7 not used 8 not used 1 4 4 RJ45 for 10 100 1000 Ethernet Ports Table 1 10 defines the pin out of the...

Страница 20: ...tect from DCE 2 RXD In Receive Data from DCE 3 TXD Out Transmit Data to DCE 4 DTR Out Data Terminal Ready to DCE 5 GND Pwr Signal Ground 6 DSR In Data Set Ready from DCE 7 RTS Out Request To Send 8 CT...

Страница 21: ...1 13 defines the pin out of the DB9 female connector used with serial ports on the DX940 when they are configured for the RS485 interface Table 1 13 DB9 RS485 Pin out Pin Signal 1 RX_ In 2 RX In 3 TX...

Страница 22: ...NS DX Administrator s Guide 2 1 2 Site Suitability Be sure that your installation site meets the following criteria Conforms with the temperature and humidity ranges detailed in Table 1 2 Can meet the...

Страница 23: ...box DX940 unit Appropriate mounting brackets 19 rail or DIN Rail or panel as ordered with screws Console Cable DB9 terminations 10 long Ethernet cable RJ45 terminations 10 long Be sure that all the e...

Страница 24: ...guration Figure 2 1 Top View 19 Rail Conventional and Reverse Mounting Conventional Mounting The brackets for mounting in a 19 inch rail system attach with two screws to the screw holes located toward...

Страница 25: ...CHAPTER 2 INSTALLATION Page 25 Figure 2 2 19 Rail Mounting brackets Figure 2 3 19 Rail Conventional Mounting Dimensional Drawing...

Страница 26: ...se Mounting The brackets provided for reverse mounting have an opening in their forward projecting parts to accommodate the power cable Figure 2 4 19 Rail Reverse Mounting brackets Figure 2 5 19 Rail...

Страница 27: ...attaches with two screws to the screw holes located toward the rear of the DX940 see Figure 1 4 You can adjust the distance of the DX940 from the panel to two positions by your selection of which pair...

Страница 28: ...in a DIN Rail System To mount the DX 940 on the DIN Rail follow the following steps 1 Purchase the SCC DX 00 DM part which provides the DIN Rail for DX940 2 Unpack the ACC DX 00 DM kit 3 Discard the P...

Страница 29: ...32x1 4 screws for each bracket as shown below 5 Attach the DIN Rail Latches to the Panel Mount Brackets with the latch plungers oriented to the rear of the DX using two 10 32x3 8 screws as shown belo...

Страница 30: ...g and power supply connector are located on the rear of the unit as shown below Figure 2 10 Ground and Power Connections ELECTRICAL WARNING Verify that a proper ground connection is made from the grou...

Страница 31: ...re 5 Re insert the plug into the power connector and secure the two captive mounting screws Figure 2 11 Non Polarized Power Input 2 3 3 Connecting to the Console Port and the Alarm Port 2 3 3 1 Consol...

Страница 32: ...able Providing strain relief on these cables will ensure a stable connection 4 Return to step one above and connect the remainder of the serial cables 2 3 4 2 Connecting Ethernet Copper Cables The Eth...

Страница 33: ...ions detail disconnecting all connections to the chassis removing the chassis cleaning optical devices and packing the DX940 for return to the manufacturer If it is still possible to connect a termina...

Страница 34: ...d in then add the end Styrofoam pieces around the chassis and place the unit in the box Please contact customer support to receive a valid RMA number so that this item is either repaired and returned...

Страница 35: ...9071 Fax 510 438 9072 Email Tech support support garrettcom com Email Sales sales garrettcom com WWW http www garrettcom com GarrettCom Europe Waterside House Haslar Marine Technology Park Haslar Rd G...

Отзывы: