background image

Magnum 6KQ Managed Field Switch Installation and User Guide             (04/07)

 

 
 

41

www  GarrettCom  com

.

.

“10/100” LED indicating 100Mb when lit (or 10 Mbps when off). 

 

Note:

  The 10/100 RJ-45 ports are supported with Auto-negotiation and Auto-

crossover (MDIX), which allow the RJ-45 ports to automatically Link with any 
RJ-45 device and eliminate the use of cross-over cable.  

 

NOTE:  for Power Substations:   In support of the IEEE 1613 Class 2 standard, GCI 

advises that, for substation applications, the RJ-45 ports are intended for 
connectivity to other communication equipment such as routers or 
telecommunication multiplexers installed in close proximity (i.e., less than 2 
meters or 6.5ft) to the 6KQ. It is not recommended to use these ports in 
substation applications to interface to field devices across distances which 
could produce kigh (greater than 2500V ) levels of ground potential rise (GPR) 
during line-to-ground fault conditions. The 6KQ passes the 1613specifications 
for zero packet loss with fiber ports & with RJ45 ports used as indicated here.

 

 

5.2.10  PoE  power-pass-through, Base unit Model 6KQP-48VDC, 10/100Mb 4-port 

 

See Section 2.2.3 for basic PoE ports information. 

The LEDs on PoE ports are slightly different compared to regular (non-PoE) 

RJ-45 modules.. When the PoE port is in use, the PoE LED is ON when connected 

properly to a 803.af compliant PD device on that port. When non-PoE devices are 

connected, the PoE LED is OFF. Operation of Ethernet data traffic is not affected by 

PoE. 

LINK and ACTIVITY LEDS are combined on the PoE modules into one LED 

that is marked as LINK/ACT. 

 

PoE LEDs Summary 

• 

For PoE devices, each RJ-45 PoE port supports only 802.3af complaint 
devices. The PoE LED is ON when the attached PD is drawing power from the 
port. 

• 

For non-PoE devices connected, the PoE port will act as a normal RJ-45 port 
and the PoE LED is OFF.  No power is being sent out from the port. 

• 

The PoE ports in Magnum 6K’s with 48VDC power input act as a pass-
through, so the 48VDC power source must be strong enough to provide power 
to the 6K switch and to all the 4 RJ-45 ports with PD devices connected (up to 
15 watts per PoE port). 

• 

In the case where the 48VDC power in not internally connected and no power 
is coming to the PoE ports for some reason, all the PoE port LEDs are ON 
simultaneously to indicate a trouble condition. The ports will still operate 
properly for data traffic. 

 

 

Содержание Magnum 6KQ

Страница 1: ...i www GarrettCom com Magnum 6KQ Managed Field Switch Hardware Installation and User Guide...

Страница 2: ...sonal Switch are trademarks and Personal Hub is a registered trademark of GarrettCom Inc Important The Magnum 6KQ Managed Field Switch contains no user serviceable parts Attempted service by unauthori...

Страница 3: ...anufacturer s instructions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in...

Страница 4: ...Optic ST type twist lock 20 3 2 2 Connecting Fiber Optic SC type Snap In 21 3 2 3 Connecting Single Mode Fiber Optic 21 3 2 4 Connecting Twisted Pair CAT3 CAT5 21 3 2 5 Connecting Twisted Pair CAT5e...

Страница 5: ...orm factor and 40 5 2 9 6KQ4 RJ45 Twisted Pair 10 100Mb 4 Port 40 5 2 10 PoE power pass through Base unit Model 6KQP 48VDC 41 5 2 11 SFPs Gigabit 1000Mbps port modules 42 5 2 12 6KQ BLNK 43 6 0 TROUBL...

Страница 6: ...RFORMANCE QUAD SERIES FIBER SWITCHES 100 10MBPS FIBER AND COPPER PORTS MIXED SPEED AND MIXED MEDIA TYPES FULL SWITCHING PERFORMANCE MP62 AND P62F OUTDOOR ETHERNET SWITCHES FOR TEMPERATURE UNCONTROLLED...

Страница 7: ...E 802 3ab 1000BASE X Ethernet IEEE 802 1p Priority protocol IEEE 802 1d Spanning tree protocol IEEE 802 1w Rapid Spanning tree protocol IEEE 802 1q VLAN Tagging IEEE 802 3x Flow Control IEEE 802 3ad L...

Страница 8: ...00 10 ON 100Mbps speed OFF 10 Mbps Operating Environment Ambient Temperature 40 to 140 F 40 to 60 C for UL60950 and Component Parts rating 60 to 195 F 50 to 85 C for IEC 60068 Type Test short term rat...

Страница 9: ...ompliance UL listed UL60950 cUL CE Emissions meet FCC Part 15 Class A NEBS Level 3 and ETSI Compliant IEEE 1613 Class 2 Environmental Standard for Electric Power Substations See also Note for Power Su...

Страница 10: ...watts panel or DIN RAIL mount PSAC 48V150 External Hardened Power Supply for AC to 48VDC for PoE 150 watts panel or DIN RAIL mount Please use this URL for the complete Configuration Guide for the Mag...

Страница 11: ...en transceiver port one10 100 1000 RJ 45 ports 6KQ 1GSFP SFP Gig module w one SFP pluggable open transceiver ports 6KQ 1GCU Copper Gig module w one10 100 1000 RJ 45 ports Gigabit 1000Mb SFP Small Form...

Страница 12: ...user selected port module options installed 1 Set of two metal vertical mounting brackets with screws to the case 1 Installation and User Guide this manual 1 Product Registration Card Remove the item...

Страница 13: ...Magnum 6KQs are ideal for building a switched hardened Ethernet network infrastructure connecting edge devices such as PLCs and IEDs with upstream switches or routers Designed for use in industrial ap...

Страница 14: ...d 802 1p QoS Traffic Prioritization Magnum 6KQ switches are plug and play and are designed for use in connecting edge devices such as PLCs IEDs and PoE video cameras with upstream switches and routers...

Страница 15: ...MLC or SLC below In a four port SFF Small Form Factor fiber port module all of the fiber ports are of the same speed 100Mb mode and connector type Small Form Factor SFF Fiber Ports come in multi mode...

Страница 16: ...tion on that port when lit The blinking ACT Activity LED indicates receiving Activity on that port when lit The 10 100 LED indicates operation at 100Mb speed when ON and at 10 Mb speed when OFF when a...

Страница 17: ...rly to an 803 af compliant PD device on that port When non PoE devices are connected the PoE LED is OFF The operation of Ethernet data traffic is not affected by PoE LINK and ACTIVITY LEDS are combine...

Страница 18: ...be available as a special order request quote 2 2 6 SFP Gigabit 1000Mbps port modules The Gigabit port options for the modular slot come in a few different configurations of Fiber SFP s or RJ 45 s The...

Страница 19: ...y queues that can be shared across the eight levels of defined packet priorities for application specific priority control by the user through software configuration settings 2 2 8 Frame Buffering and...

Страница 20: ...m 6KQ s come with Rel3 6 licensed MNS 6K software which allows the user to configure the Magnum 6KQ as a Managed Switch and implements security features and other software enabled features NOTE Magnum...

Страница 21: ...s One is for hardware and will signal loss of power internally The other is software controllable and will signal user defined software events such as a security violation or an S Ring fault condition...

Страница 22: ...ber cabling into the LAN structure Example 1 Magnum 6KQ Switch for a Industrial Application Equipped with lots of useful features including hardened enclosures a wide spread of DC power supply options...

Страница 23: ...m 6KQ Switch helps create a database of all the network subnets to easily manage the network Fig 2 4a The industrial factory floor application with Magnum 6KQ Example 2 A managed network is needed to...

Страница 24: ...AN RMON STP and other standard managed LAN features to provide a secure and stable network The 6KQ Managed Fiber with S ring and Link Loss Learn features easily fulfill the redundant requirement with...

Страница 25: ...e or broadband uplink allows the telecom user a very effective solution to store their sensitive data securely Fig 2 4c Magnum 6KQs deployed in a video security CCTV application for monitoring and sec...

Страница 26: ...dually selected and configured per slot See Section 2 2 for a description of the PMs The various media types supported along with the corresponding IEEE 802 3 802 3D 802 3u 802 3AB and 802 3z standard...

Страница 27: ...stallations using a PM with SC type fiber connectors i e using 6Kq MSC 6KQ SSC single mode When connecting fiber media to SC connectors simply snap on the two square male connectors into the SC female...

Страница 28: ...in substation applications to interface to field devices across distances which could produce kigh greater than 2500V levels of ground potential rise GPR during line to ground fault conditions The 6K...

Страница 29: ...ange of networking kit Side View Duplex LC connector Front view Note It is highly recommended to remove the fiber cable first before removing the SFP transceiver for any reason Not removing the fiber...

Страница 30: ...tissue dampened in alcohol Make certain the connectors are clean before connecting Note One strand of the duplex fiber optic cable is coded using color bands at regular intervals you must use the colo...

Страница 31: ...t If LINK is not lit or OFF after cable connection the normal cause is improper cable polarity Swap the fiber cables at the PM connector and also check the connectivity on the target device to remedy...

Страница 32: ...elease the 6KQ so that it can be dismounted by pulling the bottom out Once the bottom of the 6KQ is rotated out the DIN Rail latch is not engaged and the 6KQ can be moved up and out free of the DIN Ra...

Страница 33: ...l thermal techniques patent pending to move the heat generated by the electronic components inside into the case the case may be quite warm to the touch during normal operation The unit is mounted usi...

Страница 34: ...er input connection is in the same panel The first NC Alarm Contact top position switch vertically mounted is a Software Alarm operated by user settings in the MNS 6K software The user can disable the...

Страница 35: ...ble with or inter changeable with the other Magnum 6K Family Switches PMs which use larger typically 8 port modules 3 7 Connecting a Management Console Terminal to Magnum 6KQ Serial RJ45 Console Port...

Страница 36: ...hing Functionality A Magnum 6KQ provides switched connectivity at Ethernet wire speed among all of its ports The Magnum 6KQ supports10 100Mbs for copper media and 10 or 100Mb separate traffic domains...

Страница 37: ...Steady ON Link status for 10 Mbps and 100Mbps operation ACT ON with port activity for 10 Mbps and 100Mbps operation F H Full Half duplex LED ON when the port is running full duplex OFF for half duple...

Страница 38: ...egotiation and are connected to another auto negotiating device there are 4 different speed and F H modes possible depending on what the other device supports These are 1 100Mb full duplex 2 100Mb hal...

Страница 39: ...lex ports which provides for a PAUSE packet to be transmitted to the sender when the packet buffer is nearly filled and there is danger of lost packets The transmitting device is commanded to stop tra...

Страница 40: ...Multi Mode 2 2 850 62 5 125 100 140 50 125 15 0 9 5 19 5 31 31 31 14 19 5 19 5 5 5 9 3 4 17 23 5 13 5 6 7 4 8 6KPV MST MSC 100Mb FX Multi mode 2 0 4 1300 62 5 125 50 125 20 23 5 31 31 9 0 5 5 3 0 2 0...

Страница 41: ...ipment or delivery Inspect the contents of this package for any signs of damage and ensure that the items listed below are included This package should contain 1 or more 6KQ units or 6KQ PMs Installat...

Страница 42: ...standard distance 100m on each port and the fiber port supports fiber optic cable distances up the IEEE standard 100Mbps distance limits i e typically 2km at full duplex and 412m at half duplex Each p...

Страница 43: ...quipped with SC type snap in fiber port connector instead of an ST type 5 2 3 6KQF 2SSCL 2 Ports 100Mbps single mode FX SC type Sgl M The Magnum 6KQF 2SSCL is also a Fiber module equipped with 2 Singl...

Страница 44: ...2 5 6KQ4 MT 4 100Mb multi mode FX MTRJ Small Form factor Magnum 6KQ4 MT is a multi mode fiber optic 4 port module equipped with a small form factor MTRJ type connector It looks almost like an RJ 45 po...

Страница 45: ...indicates 100Mbps speed when lit and at 10Mbps speed when off 5 2 7 6KQ4 MLC 4 ports 100Mbps multi mode LC connector SFF Magnum 6KP8 MLC is a Four port multi mode fiber LC connector small form factor...

Страница 46: ...uplex when off The 10 100 LED indicates 100Mbps speed when lit and at 10Mbps speed when off 5 2 9 6KQ4 RJ45 Twisted Pair 10 100Mb 4 Port The 6KQ4 RJ45 module supports Ethernet twisted pair segments of...

Страница 47: ...DC 10 100Mb 4 port See Section 2 2 3 for basic PoE ports information The LEDs on PoE ports are slightly different compared to regular non PoE RJ 45 modules When the PoE port is in use the PoE LED is O...

Страница 48: ...iber port modules on the Magnum 6KQ are normally set factory default to operate at AUTO mode for best fiber distance and performance Only two Gigabit ports can be configured on a Mangum 6KQ managed sw...

Страница 49: ...istance or contact GarrettCom Customer Support 6 1 Before Calling for Assistance 1 If difficulty is encountered when installing or operating the unit refer back to the Installation Section of the appl...

Страница 50: ...repair must be accompanied by a Return Material Authorization RMA number To obtain an RMA number please use this URL https rma garrettcom com rma rma_request_noaccount php to fill out the form Please...

Страница 51: ...Customer Service APPENDIX A WARRANTY INFORMATION GarrettCom Inc warrants its products to be free from defects in materials and workmanship for a period of three 3 years from the date of shipment by Ga...

Страница 52: ...RY OF OPERATION The 48VDC 24VDC and 125VDC power options are designed using diodes inside on each DC power input line behind the two external power connection terminals so that the power from an exter...

Страница 53: ...The chassis is earth or ground GND The connection procedure is straightforward Simply insert the DC leads to the Switch s power terminals positive and negative screws The use of Ground GND connects to...

Страница 54: ...Power Supply Internal 125VDC Dual Source model Dual Src 125V DC Power Connector First Source A A 2nd Source B B GND ground wire connection to the hub chassis screw Input Two separate sources each at...

Страница 55: ...the internal power supply because of the blocking action of the diodes This is true even if one input connection is reversed while the Switch is operating from the other source e The Switch will not...

Страница 56: ...or equivalent 5 Fastening torque of the lugs on the terminal block 9 inch pound max 6 Centralized DC Power Source cable securement use at least four cable ties to secure the cable to the rack at least...

Отзывы: