Magnum 6K8-Series Industrial Field Switch             Installation and User Guide   03/06) 

 

27

www  GarrettCom  com

.

.

 

Fig 3.3 - Magnum 6K8 mounted 
vertically with DIN-Rail brackets and 
latches 

The DIN-Rail mounting brackets 

and latches are optional and need to be 
ordered as separate items, e.g Model # DIN-
RAIL-6K8

 

3.3.1 Installing 

DIN-RAIL 

variable brackets on 
Magnum 6K8 

Magnum 6K8 Din-Rail kit comes along 
with the following-

BOM: 

Item 

Quantity     Description 

    DIN Rail Clip assy 

    #10-32 x ¼ Phillip  

 

    Flat head screws with 

undercut 

    #4-40 x 3/8 Phillip Flat head screw 

 

Din-Rail kit Installation procedures: 

 

1. Remove the back plate from Magnum 6K8 UNIT 

a. There are eight screws along the edge of  the unit to remove. 

b.. Do not re-use the old screws. 

 

2. On the back-plate 

a. Locate the indented side with 1, 11…… 

b. “1” indentation signify center of the mounted Din-Rail clip 

 

location.

 

c. Each indented locations (1-11-111…) are ½ inches apart from the center. 

 

 

Fig 1. 

 
3. 

Select the height position via 

indented side marking .

 

 
4. Place the 

DIN Rail Clip 

assembly under indented side of 
the plate. Place two of the screws, 
came along the kit (#10-32 x ¼ 
Phillip Flat head screws with 
undercut) onto the indented side 
and screw tight the assembly as 
shown in Fig 2a.  
Note: Make sure the screws must 
have the 5lbs/in torque minimum. 

Содержание Magnum 6K8-Series

Страница 1: ...www GarrettCom com Magnum 6K8 Series Industrial Field Switch Hardware Installation and User Guide...

Страница 2: ...sonal Switch are trademarks and Personal Hub is a registered trademark of GarrettCom Inc Important The Magnum 6K8 Series Industrial Field Switch contains no user serviceable parts Attempted service by...

Страница 3: ...e manufacturer s instructions may cause interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications...

Страница 4: ...hernet Media 23 3 2 1 Connecting Fiber Optic ST type twist lock 23 3 2 2 Connecting Fiber Optic SC type Snap In 24 3 2 3 Connecting Single Mode Fiber Optic 24 3 2 4 Connecting Twisted Pair Unshielded...

Страница 5: ...ti mode FL ST type twist lock connector49 5 2 5 6KP8 MTRJ small Form factor 50 5 2 5a 6KP6 MT10ST MTRJ Small Form Factor ST Fiber port 50 5 2 6 6KP8 45MT MTRJ Small Form Factor 51 5 2 7 6KP8 MLC Small...

Страница 6: ...Switches 100 and 10 Mbps copper ports with optional fiber port with auto negotiating full switching performance Quad Series Fiber Switches MODULAR 100 10Mbps fiber and copper ports mixed speed and mix...

Страница 7: ...t Lengths Unshielded twisted pair 100 m 328 ft Shielded twisted pair 150 m 492 ft 10BASE FL multi mode fiber optic 2 km 6 562 ft 10BASE FL single mode fiber optic 10 km 32 810 ft Maximum Standard Fast...

Страница 8: ...F 50 to 100 C Ambient Relative Humidity 5 to 95 non condensing Altitude 200 to 13 000 ft 60 to 4000m Conformal Coating humidity protection option Request quote Alarm Relay Contacts One NC indicating i...

Страница 9: ...the devices Also port specific user settings such as FDX or HDX copper 10 100 speed can be fixed using software commands Mountings Vertical mounting only Suitable for wall or DIN Rail mounting Agency...

Страница 10: ...wing single or multi mode fiber copper 1000 100 or 10Mbps modules Magnum 6K8 Port Modules 6KP8V RJ45 TP Module with 8x10 100Mbps auto negotiating RJ 45 ports 6KP8V MTRJ SFF Fiber module with 8x100Mb m...

Страница 11: ...th 1310nm single mode SC 10km fiber connector GBIC LXSC25 One 1000BASE LX LH port with 1310nm single mode SC 25km fiber connector GBIC ZXSC40 One 1000BASE ZX port with 1550nm single mode SC 40km fiber...

Страница 12: ...1 Product Registration Card Remove the items from the shipping container Be sure to keep the shipping container should you need to re ship the unit at a later date To validate the product warranty ple...

Страница 13: ...new standard for Industrial and Carrier Class applications heavy duty Ethernet Switch requirements are readily accommodated with an extended temperature rating of 40 C to 60 C calculated by the UL Com...

Страница 14: ...standard managed switch to meet the Industrial expectation For high availability Redundant LANs using ring mesh topologies Spanning Tree Protocol Rapid Spanning Tree Protocol Link Loss Learn and S Rin...

Страница 15: ...nted vertically using the vertical mounting brackets which come along with the unit or by using the DIN RAIL KIT optional for Din rail mounting Loaded with versatile and secured management software MN...

Страница 16: ...or best fiber distance and performance Using the 6K MNS software the user may select full or half duplex mode per port through set up of the software See Magnum 6K MNS Software Manual for the flexibil...

Страница 17: ...d The FDX HDX LED is ON to indicate full duplex operation and OFF to indicate half duplex mode A twisted pair cable must be connected into an RJ 45 port and the Link LK indicator for that port must be...

Страница 18: ...For detailed information about 10Mb mm ST fiber half of the module see Section 2 2 5 2 2 5 Four Port 10 Mb and 100Mb mm Fiber ST Modules The 4 port 10Mb ST fiber modules behave the same as the 4 100M...

Страница 19: ...lly set factory default to operate at AUTO mode for best fiber distance and performance The 1000Mbps SC fiber optic module on the Gigabit SX and Gigabit LX transceivers are compatible with the IEEE 80...

Страница 20: ...isions to be forwarded which add to the network traffic Since there is no way to filter frames with a bad CRC the entire frame must be present in order for CRC to be calculated the result of indiscrim...

Страница 21: ...d m6kuser All MNS 6K software information including new releases and upgrades related to MNS 6K software can be accessed and download from GarrettCom s FTP site Alternatively for documentation and lat...

Страница 22: ...oss of power internally The other is software controllable and will signal user defined software event traps such as a security violation or an S Ring fault condition Vertical mounting for efficient c...

Страница 23: ...is ideal for integrating future proof fiber cabling into the LAN structure Example 1 Magnum 6K8 Series Switch for a Industrial application Equipped with lots of useful features such as a hardened Ind...

Страница 24: ...supported by the Magnum 6K8 Series Switch A main NT server in a secure area protected from earthquake or fire hazards can be connected to the full duplex Gigabit Fiber port Extended temp ratings 24V 1...

Страница 25: ...h a viewable SNMP monitor The NEMA TS 2 and TEES along with IP53 approval with the mix of copper and fiber ports on the 6K8 Series Industrial Field Switch provides an economical and seamless solution...

Страница 26: ...e controlled Alarm Relay which easily qualifies it to provide all the requirements of substations The successful track record of previous members of the 6K family in sub stations also adds another exa...

Страница 27: ...anical loading D Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on over current p...

Страница 28: ...responding IEEE 802 3 802 3D 802 3u 802 3AB and 802 3z standards and connector types are as follows IEEE Standard Media Type Max Distance Port Module Fiber 1000BASE FX mm1 Fiber 220m ft GBIC SXSC sgl...

Страница 29: ...Single mode fiber cable has a smaller diameter than multi mode fiber cable 9 125 microns for single mode 50 125 or 62 5 125 microns for multi mode where xx xx are the diameters of the core and the cor...

Страница 30: ...ielded twisted pair cabling is 100 meters 328 ft Media IEEE Standard Connector Twisted Pair CAT 5E 1000BASE T RJ 45 NOTE It is recommended that high quality CAT 5E cables which work for both 100 Mb an...

Страница 31: ...it hold the 6K8 in the vertical position with the bottom out and with the top moved in toward the DIN Rail Position the latches over the top of the DIN Rail Then snap the latches into holding position...

Страница 32: ...t head screw Din Rail kit Installation procedures 1 Remove the back plate from Magnum 6K8 UNIT a There are eight screws along the edge of the unit to remove b Do not re use the old screws 2 On the bac...

Страница 33: ...Fig 2b with arrow mark Fig 2a 10 32 Screws on indented side Fig 2b Din Rail assembly w plate applied to mount the Din Rail assembly underneath 5 Remount the Din Rail assembled plate onto the Magnum 6K...

Страница 34: ...fe reliability It is also advisable to mount the unit with space for air movement around the top and the sides typically a minimum of 1 inch Note that the back of the 6K8 unit is held out from the pan...

Страница 35: ...al power supply and have a recessed male IEC connector for the AC power cord at the left rear A manual power ON OFF switch is adjacent A six foot 115 VAC 60 Hz standard power cord is supplied with eac...

Страница 36: ...ing normal software operation A user defined software malfunction such as an SNMP Trap or a Software Security violation or an S Ring Fault causes the contact to open and thus trigger an alarm in the u...

Страница 37: ...any PM cards Failure to do so may result in damage to the unit and will void the warranty Caution Avoid Static Discharge The port modules like most electronic equipment are sensitive to static dischar...

Страница 38: ...e power supply When the chassis top cover has been removed the interior of the unit is exposed Looking down into the Magnum 6K8 Series unit notice that there are PM module installed and daughter modul...

Страница 39: ...plate tightly There are no screws used on holding the screen face plate Figure 3 6 1d Removing PM screen Plate 3 6 2 Installing 6KPM Cards in the Magnum 6K8 Series Only one front mounted 6KPMV Module...

Страница 40: ...es the basic layout of an individual PM card Each 6KPM card fits into the space provided on the main board Fig 3 6 2d Daughter Board top view of 4 copper 10 100 ports Fig 3 6 2e Daughter Board shown u...

Страница 41: ...ies Step 6 Now screw down the daughter board with 6 440 screws so that it holds the daughter board securely The figure on the left shows the top view of successfully installed 6KPMV cards inside and t...

Страница 42: ...before securely sliding the chassis base track inside the top cover properly as shown in Fig 3 6 2h Fig 3 6 2h sliding in the top cover onto the chassis base track 3 6 3 Removing 6KPM Cards To proper...

Страница 43: ...Magnum 6K8 Use a DB 9 null modem cable use on any serial port or one DB 9 and one USB USB port on the laptop null modem cable to connect the Magnum6K8 Series Console Port the RS 232 port on the 6K8 S...

Страница 44: ...ormation 3 7 1 RS 232 DB 9 Console Com port Serial port pin assignments Pin 1 Pin 5 DB 9 Console port connector Pin Signal Description 1 CD Carrier detect not used 2 RXD Receive Data input 3 TXD Trans...

Страница 45: ...h are described below Filtering and Forwarding Each time a packet arrives on one of the switched ports the decision is taken to either filter or to forward the packet Packets whose source and destinat...

Страница 46: ...ed mode at 10Mb or 100Mb Half Full Duplex managed switch No cross over cable is required while using the 6K8 s copper port to other devices Operation is according to the IEEE 802 3u standard The Manag...

Страница 47: ...ntially an externally controlled process the original highest order mode result can change at any time depending on network changes that may occur If the device at the other end is not an auto negotia...

Страница 48: ...unicate properly during normal operation Note When in Half Duplex mode the 6K8 Series Switch implements a back pressure algorithm on 10 100 Mb ports for flow control That is the switch prevents frames...

Страница 49: ...0 4 1300 62 5 125 50 125 20 23 5 31 31 9 0 5 5 3 0 2 0 15 8 12 2 5 5 4 0 6KPV MLC 100Mb FX Multi mode 2 0 4 1300 62 5 125 19 31 12 4 16 5 7 6KPV SLC 100Mb FX Single Mode 15 0 4 1310 9 125 15 28 11 22...

Страница 50: ...separately at a later date In the event there are items missing or damaged contact your supplier If you need to return the unit use the original shipping container if possible Refer to Chapter 5 for...

Страница 51: ...alf duplex when off The 10 100 LED indicates the speed if the LED is ON 100Mbps if it is OFF 10Mbps 5 2 1a 6KP6 RJ10ST 4 10 100Mbps RJ 45 and 2 10Mb multi mode FX ST twist lock Combo Module The 6KP6 R...

Страница 52: ...nient way for the half duplex hub to connect to the switch through 10Mb fiber ports It supports distances according to the 10Base FL standard i e 2Km distance for multi mode fiber Single mode for 10Km...

Страница 53: ...transceivers all in one module This is similar to the 6K6 RJMST It has the same LEDs indicating port activity ACT Link LK and FDX HDX and 10 100 operation and the same face plate lettering While the f...

Страница 54: ...ries Switches supporting four Copper and two single mode Long Reach fiber network segments The 6KP6 RJSSC when installed in a Magnum 6K8 Series Switch has copper supporting the 100m distance and Fiber...

Страница 55: ...2m at half duplex The functionality of this 100BASE FX multi mode 8 Port module is essentially the same as the ST and SC types It has the same LEDs per port indicating port activity ACT Link LK and FD...

Страница 56: ...similarly 5 2 7 6KP8 MLC 8 ports 100Mbps multi mode LC connector Small Form Factor Magnum 6KP8 MLC is a eight port multi mode fiber LC connector small form factor used primarily in 100Mbps fiber to t...

Страница 57: ...he standard distances as per mentioned on 5 2 8 and the LEDs also acts similarly as mentioned above 5 2 9 6KP8 RJ45 Twisted Pair 10 100Mb 8 Port The 6KP8 RJ45 module supports Ethernet twisted pair seg...

Страница 58: ...5 ports are supported with Auto negotiation and Auto crossover MDIX which allow the RJ 45 ports to automatically Link with any RJ 45 device and eliminate the use of cross over cable 5 2 10 6KP8 45 2MT...

Страница 59: ...lex 1 1000Mb Fiber SC 4 10 100Mb The GBIC transceiver has been offered in the modular slot with multiple options as per the user requirement The two Giga port has been offered as GBPM 2OTX fiber or RJ...

Страница 60: ...ns It supports cable distances up to the IEEE 802 3z standard 1000Mbps distance limits i e 10 25 40 or 70Km at full duplex and depend upon the Gigabit modules used 1 1000Mb Fiber SC 2 100Mb SC The two...

Страница 61: ...to the Installation Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable 2 Check the cables and connectors to ensure th...

Страница 62: ...f the problem Any changes to system administration procedures should all be noted in this record 6 3 Return Material Authorization RMA Procedure All returns for repair must be accompanied by a Return...

Страница 63: ...Attn Customer Service APPENDIX A WARRANTY INFORMATION GarrettCom Inc warrants its products to be free from defects in materials and workmanship for a period of three 3 years from the date of shipment...

Страница 64: ...ully loaded fiber ports 24V 48V 125V DC 8 watts typical for all RJ 45 Ports B2 0 48VDC 24VDC and 125VDC POWER THEORY OF OPERATION The 48VDC 24VDC and 125VDC power options are designed using diodes ins...

Страница 65: ...applications are mainly in the Industrial environment such as factory floor HVAC equipment military equipment etc The 5VDC options are mainly used for military or Industrial factory floor application...

Страница 66: ...cable ties to secure the cable to the rac k at least 4 inches apart with the first one located within 6 inches of the terminal block B5 0 OPERATION Operation of Magnum 6K8 Series Switches with the opt...

Страница 67: ...to the standard AC powered models Refer to the main sections of this Installation and User Guide for a detailed description of the Magnum 6K8 Series Switches C3 0 DUAL SOURCE OPTION THEORY OF OPERATIO...

Страница 68: ...C Note The GND should be hooked up first The 6K8 Series unit has a floating ground so the user may elect to Ground either or terminal to suit the customer s use Before connecting hot lines to the Term...

Страница 69: ...RING INFORMATION Optional To order the optional Dual Source 48VDC power supply factory installed order Dual Src48V as a separate line item following the product model Example Magnum 6K8 48VDC Dual Src...

Отзывы: