Magnum 6K32 Managed Switch            Installation and User Guide (02/05)

 

 

www  GarrettCom  com

.

.

 

 
 

Fiber connector types supported: 

  

 ST-type 

(twist-lock) 

 

  

 SC-type 

(snap-in) 

 

   

MTRJ-type Small Form Factor (SFF) 

 

   

LC-type    Small Form Factor (SFF)  

  

 GBIC 

modules 

 

 

 

 

LEDs: Per Port 

  

LK: 

Steady ON when media link is operational  

 

 

ACT: 

ON with receiver port activity

 

 

 

FDX/HDX:  

ON = Full-Duplex Mode 

 

 

                     OFF = Half-Duplex Mode

 

 

 

100/10: 

ON = 100Mbps speed 

 

 

 

       OFF = 10 Mbps  

 

 Operating 

Environment 

 

  Ambient Temperature:  25

°

 to 130

°

 F (-5

°

 to 55

°

C) 

 

 

Storage Temperature:   -40

°

to 185

°

F (-40

°

to 85

°

C) 

 

 

Ambient Relative Humidity:  5% to 95% (non-condensing) 

 

 

Altitude: -200 to 13,000 ft. (-60 to 4000m) 

 

 

Conformal Coating option: Request quote

 

 Packaging 

 

 

Enclosure:  Rugged High strength metal. Suitable for stand-alone    

 

 

 

or rack-mounting  

 

 

 

  

 

 

Dimensions:   1.70in. H x 17.0in. W x 9.0in.  D 

 

 

 

4.32cm H x 43.2cm W x 22.9cm D  

 

 

Cooling method:  Fan cooled, @ 3@ 7 cfm ea.

 

 

Management Console connector 

 

DB-9 for RS-232 “ null-modem “ cable (sometimes called an X-modem cable) 

 

Power Supply (Internal) 

 

AC Power Connector:  IEC-type, male recessed at rear of chassis,  

with adjacent manual ON-OFF switch (optional if no Alarms Cont.) 

 

Input Voltage:  100 to 240 VAC (auto-ranging) 

 

Input Frequency:  47 to 63 Hz (auto-ranging) 

 

Power Consumption: 45 watts max  (with fiber module) 

 

 

 

                     30 watts for a fully-loaded copper only model 

        DC Power Supply (Options)

 

-48VDC Power

 Input Voltage : -36 to -70 VDC  

 24VDC Power 

Input Voltage : 20 to 40VDC 

125VDC Power and 100VDC 

Input Voltage : 88 to 150VDC 

Std. Terminal Block :   “ -, GND, + ” 
Power Consumption: same as for AC models, see above 

For (

Optional

) DC internal power supplies at –48VDC, 24VDC and 125VDC, 

including Dual Source options (

for continuity of operation when either of the DC 

input sources are interrupted)

, see Appendices B and C. 

Содержание Magnum 6K32

Страница 1: ...Corporate Headquarters GarrettCom Inc 47823 Westinghouse Drive Fremont CA 94539 Phone 510 438 9071 Fax 510 438 9072 Website http www GarrettCom com email support garrettcom com Magnum 6K32 Managed Swi...

Страница 2: ...sonal Hub is a registered trademark of GarrettCom Inc GarrettCom Inc reserves the right to change specifications performance characteristics and or model offerings without notice Important The Magnum...

Страница 3: ...e to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules which are desi...

Страница 4: ...ng Fiber Optic ST type twist lock 21 3 2 2 Connecting Fiber Optic SC type Snap In 21 3 2 3 Connecting Single Mode Fiber Optic 22 3 2 4 Connecting Twisted Pair 22 3 2 5 Connecting Twisted Pair 22 3 3 T...

Страница 5: ...Small Form Factor 46 5 2 8 6KP8 45LC Combo factor and RJ 45 Connector 47 5 2 9 6KP8 RJ45 Twisted Pair 10 100Mb 8 Port 47 5 2 10 6KP8 45 2MT multi mode FX MTRJ Small Form Factor 48 5 2 10a 6KP8 45 2LC...

Страница 6: ...orts mixed speed and mixed media types full switching performance Outdoor Ethernet Switches for temperature uncontrolled locations 6 10 100 and 2 100Mb fiber ports can be connected in strings and ring...

Страница 7: ...Spanning tree protocol IEEE 802 1w Rapid Spanning tree protocol IEEE 802 1q VLAN Tagging IEEE 802 3x Flow Control IEEE 802 3ad Link Aggregation Trunking Maximum 10 Mbps Ethernet Segment Lengths Unshi...

Страница 8: ...0in H x 17 0in W x 9 0in D 4 32cm H x 43 2cm W x 22 9cm D Cooling method Fan cooled 3 7 cfm ea Management Console connector DB 9 for RS 232 null modem cable sometimes called an X modem cable Power Sup...

Страница 9: ...1 located next to the port internally Note Other port specific user settings such as FDX or HDX AUTO OFF copper 10 100 speed can be configured using software commands Agency Approvals UL listed UL195...

Страница 10: ...2R except the power input is 24VDC Magnum 6K32 125VDC Same as 6K32 except the power input is 125VDC Magnum 6K32R 125VDC Same as 6K32R except the power input is 125VDC Configuration Options Each Magnum...

Страница 11: ...ceiver module for use in GBPM xOTX One 1000BASE LX LH port with 1310nm single mode SC 25km fiber connector GBIC LXSC40 GBIC transceiver module for use in GBPM xOTX One 1000BASE ZX port with 1550nm sin...

Страница 12: ...port module option in modular slot 1 AC Power Cord U S and other 115 VAC only 1 Set of metal Ears for 19 rack mounting 1 Installation and User Guide this manual 1 Product Registration Card Remove the...

Страница 13: ...flexibility is achieved via a family of 6K port modules for copper and fiber built in emphasizing Small Form Factor fiber for high fiber port density 6 port modules for fiber and RJ 45 combinations a...

Страница 14: ...ed in the field See Section 5 Status LEDs are part of each port module and are viewable when connecting the Ethernet media A regular rack Figure 2 2 1a 6K32 front view configured for 24 RJ 45 ports 1...

Страница 15: ...lf duplex mode per port through set up of the software See Magnum 6K32 MNS Software Manual for the flexibility to adapt to any FDX or HDX type of Fast Ethernet devices There are three LED s per fiber...

Страница 16: ...d The FDX HDX LED is ON to indicate full duplex operation and OFF to indicate half duplex mode A twisted pair cable must be connected into an RJ 45 port and the Link LK indicator for that port must be...

Страница 17: ...and with 4 RJ45 10 100 copper and 2 10Mb fiber mm ST ports The 4 RJ 45 2 10 Mb ST operation of the SFF fiber and the RJ 45 half of the module is as described for those port types above For detailed in...

Страница 18: ...well with new models appearing often The 1000Mb Gigabit fiber port modules on the Magnum 6K32 are normally set factory default to operate at AUTO mode for best fiber distance and performance The 1000M...

Страница 19: ...ough technique permits collision fragment frames which are a result of late collisions to be forwarded which add to the network traffic Since there is no way to filter frames with a bad CRC the entire...

Страница 20: ...Magnum MNS 6K Software User guide in pdf format a separate document normally accessed via the web browser ftp ftp garrettcom com or FTP client program by ftp GarrettCom com using user m6kuser passwor...

Страница 21: ...amily to choose from The port modules are normally factory installed and tested but may be changed in the field Rack mounting may be standard or reverse 19 inch or ETSI or 23 Telco The standard rack m...

Страница 22: ...itch for a VLAN application Equipped with lots of advanced management features the Magnum 6K32 Managed switch is able to handle a VLAN application and provide security and performance in an Ethernet n...

Страница 23: ...building The entire spread network is managed to provide easy detectable uninterrupted support through a viewable SNMP monitor The Magnum 6K32 Managed Switch equipped with copper and optional dual Gi...

Страница 24: ...RETT Magnum QS5116 PW Managed Fiber Switch Magnum 6K32 1 3 5 10 100 LK F H ACT 10 100 LK 2 4 6 F H AC 1 3 5 10 100 LK F H ACT 10 100 LK 2 4 6 F H AC 1 3 5 10 100 LK F H ACT 10 100 LK 2 4 6 F H AC Data...

Страница 25: ...LK 2 4 6 8 F H AC T Magnum QS5116 Fiber Switch GARRET T Magnum QS5116 PW R Managed Fiber Switch Magnum 6K32 1 3 5 7 10 10 0 LK F H AC T 10 10 0 LK 2 4 6 8 F H AC T 1 3 5 7 10 10 0 LK F H AC T 10 10 0...

Страница 26: ...6K32 Switches The location of a Magnum 6K32 Switch is dependent on the physical layout of the network Typically the Switch is placed in a central wiring location where groups of network devices need...

Страница 27: ...dual connectors with a soft cloth or lint free lens tissue dampened in alcohol Make certain the connectors are clean before connecting Note One strand of the duplex fiber optic cable is coded using c...

Страница 28: ...It is recommended that high quality CAT 5 cables which work for both 10 Mb and 100Mb be used whenever possible in order to provide flexibility in a mixed speed network since dual speed ports are auto...

Страница 29: ...Manageable Switches can be easily mounted on a table top or any suitable horizontal surface and has four rubber feet to provide stability without scratching finished surfaces 3 3 1 Rack mounting for...

Страница 30: ...tus LEDs in the front The status LEDs that are co incident with the ports are still present there and a second or dual set of LEDs are used for status visibility in the front of the unit showing the s...

Страница 31: ...d power cord is supplied with each unit shipped within the United States and Canada The auto ranging power supply supports installation environments where the AC voltage is from 90 to 260 volts with a...

Страница 32: ...board inside of the 6K32 This provides a Hardware Alarm because the NC contacts will open when internal power is lost either from an external power down condition or by the failure of the power suppl...

Страница 33: ...hing Daughter and Granddaughter board The copper 6KPM card should not work properly if mixed with other Fiber combo 6KPM card packages Always install the PM module separately one by one to avoid the m...

Страница 34: ...tion spaces and female latch white connectors provided on the far right side of main board along with four stand off s for 6KPM card position See Figure 3 5 1c Figure 3 5 1c Magnum 6K32 s modular slot...

Страница 35: ...stalling 6KPM Cards in the Magnum 6K32 Up to four front mounted 6KPM cards may be installed in one Magnum 6K32 Managed Switch unit Follow these steps to install a 6KPM Step 1 Remove top chassis cover...

Страница 36: ...aughter Bd and the mating connector being matched to lockup properly Step 4 Hold the daughter board with both hands at the end and align the two cream color latching connectors male placed at the bott...

Страница 37: ...y the front panel screen plates come along with the 6K module need to be properly placed on the front of the chassis cover to complete the installation process Step 8 Once the 6KPM cards have been ins...

Страница 38: ...ar the latch up connectors as shown in Fig 3 5 3b If the now empty slot is to remain unused be sure to install a 6KPM BLNK face plate cover Figure 3 5 3b Removing a 6KPM Card Follow the step 8 to comp...

Страница 39: ...Port is on the Rear of Reverse 6K32 Models Note For detail description of Managed Network Software MNS 6K and Magnum 6K32 Switch configuration for Network Management please refer to Magnum 6K32 Softwa...

Страница 40: ...ces There is no software configuring necessary to be done for basic operation at installation or for maintenance The only hardware configuration settings are user options for an UP LINK Switch resides...

Страница 41: ...rt module among all the multiple choices of port modules The upper part of the copper port module 6KP8 RJ45 has a manual Up link switch located on the inside of the unit on the port module board next...

Страница 42: ...ast Ethernet media converters mostly do not support auto negotiation properly and require that the switched port to which they are connected be at 100Mb fixed speed Attachment to 10 100 auto negotiati...

Страница 43: ...ontrol is to reduce the risk of data loss if a long burst of activity causes the switch to save frames until its buffer memory is full This is most likely to occur when data is moving from a 100Mb por...

Страница 44: ...5 Single mode is 0 2 dB km LXSC70 The following data has been collected from component manufacturer s Agilent s and Lucent web sites and catalogs to provide guidance to network designers and installer...

Страница 45: ...6K32 Managed Switch Port Modules This chapter describes each Port Module PM including appearance functionality and status displays 5 1 Inspecting the Package and Product This section applies only to...

Страница 46: ...RJMST 4 10 100Mbps RJ 45 and 2 100Mb multi mode FX ST twist lock Combo Module The Magnum 6KP6 RJMST is a combo 6 port module of RJ 45 s at 10 100Mbps and fiber optic ports at 100MB The Combo module i...

Страница 47: ...s an Activity ACT LED indicating packets being received a Link LK LED that indicates proper connectivity with the remote device when lit and FDX HDX LED to indicate full duplex mode when lit or half d...

Страница 48: ...orts Whereas the 100Mb ST module allow to connect the 100Mb demand of Switch devices It supports distances according to the 10Base FL standard i e 2Km distance for multi mode fiber Single mode for 10K...

Страница 49: ...5 Each port has an Activity ACT LED indicating packets being received a Link LK LED that indicates proper connectivity with the remote device when lit and a FDX HDX LED to indicate full duplex mode w...

Страница 50: ...nector The Magnum 6KP6 RJ10ST is also a Combo module equipped with 4 dual speed copper ports and 2 multi mode 10 Mb fiber ST type connectors It provides a combination of copper and Fiber functions in...

Страница 51: ...10Mb Multi mode ST Fiber port The 6KP6 RJ10ST is a combo module with two different kinds of fiber flavor with two different speeds The top four ports of MTRJ Small form factor fiber support at 100Mb f...

Страница 52: ...nks When installed in a Magnum 6K32 Switch it supports fiber optic cable distances up to the IEEE standard 100Mbps distance limits i e typically 2km at full duplex and 412m at half duplex The compact...

Страница 53: ...RJ45 Twisted Pair 10 100Mb 8 Port The 6KP8 RJ45 module supports Ethernet twisted pair segments of any standard length It is equipped with an eight port RJ 45 connector and offers 10 100 full half dupl...

Страница 54: ...e 6KP8 RJ45 Crossover Switch Inside is set for by default from the factory for the Port 1 and act similar as other user port The location of crosss over switch can be seen in the fig 3 5 2 c RJ 45 mod...

Страница 55: ...the IEEE 802 3z standard 1000Mbps distance limits i e 550m at full duplex 1 1000Mb Fiber SC 4 10 100Mb The GBIC transceiver has been offered in the modular slot with multiple options as per the user...

Страница 56: ...shown below in the above figure Each port has an Activity ACT LED indicating packets being received and a link LK LED indicating proper connectivity with the remote device when lit 5 2 12 6KM BLNK Th...

Страница 57: ...d to each Magnum 6K32 Switch unit Be certain that each AC power cord is plugged into a functioning electrical outlet Use the PWR LEDs to verify each unit is receiving power 4 If the problem is isolate...

Страница 58: ...number http www garrettcom com techsupport RMA rma htm Or call GarrettCom Customer Service at 510 438 9071 during business hours in California or email to support garrettcom com When calling please h...

Страница 59: ...ttn Customer Service APPENDIX A WARRANTY INFORMATION GarrettCom Inc warrants its products to be free from defects in materials and workmanship for a period of three 3 years from the date of shipment b...

Страница 60: ...correctly applied to the two inputs It protects the Switch from incorrect DC input connections An incorrect polarity connection for example will neither affect the Switch its internal power supply nor...

Страница 61: ...dure is very straightforward Simply connect the leads to the Magnum unit beginning with ground Ensure that each lead is securely tightened Note The GND should be hooked up first The 6K32 unit has a fl...

Страница 62: ...NG INFORMATION To order the optional 48VDC power supply factory installed add a suffix of 48VDC after the product s standard model Example Magnum 6K32R 48VDC Similarly to order the optional 24VDC or 1...

Страница 63: ...s Dual Source option are identical to those listed in the Magnum 6K32 Fiber Switches Installation and User Guide including Appendix B Internal DC Power Supply Option C2 0 MAGNUM 6K32 with 48VDC 24VDC...

Страница 64: ...the Magnum 6Ks Switch shown in Figure The 48VDC terminal block on the Magnum 6K32 Switch as shown in Fig C5 0 is located on the right rear of the unit and is equipped with five 5 screw down lead posts...

Страница 65: ...he cable to the rack at least 4 inches apart with the first one located within 6 inches of the terminal block C6 0 ORDERING INFORMATION To order the optional Dual Source 48VDC power supply factory ins...