Magnum 6K25 Managed Fiber Switch Installation and User Guide (04/06)
28
www GarrettCom com
.
.
4. By default it is NC (normally closed)
5. The software operation need to be enable and set to get the Alarm traps. For detail
information about the Software Alarm and software control of SNMP alarm traps, please
reference the Magnum MNS-6K Software User Manual. (Chapter 19th).
3.5
6K25 Port Module (6KPM) Installation
The Magnum 6K25 Switches are normally received from the factory with all
required 6KPM modules installed. There may be situations where 6KPM cards need to
be added or replaced. In cases where additional 6KPM cards are needed, the faceplate
for an available front-mounted slot must be removed. The following procedure describes
this operation.
3.5.1 Preparation for Installing and Removing 6KPMs
STOP!!!
Be sure the power cord and connections
for all powers single or dual, is unplugged
from the chassis before attempting to remove
and/or replace any PM cards.
Failure to do so may result in damage to the unit
and will void the warranty.
Caution- Avoid Static Discharge: The port modules (like most electronic
equipment) are sensitive to static discharge. Use proper ESD measures when
handling port modules.
Step 1.
Make sure the 6KPM Card package has all necessary accessories to install it
properly. Each 6KPM Card package except the Gigabit, for field installation
contains (Daughterboard (Bigger) and Granddaughter board (smaller), three 5/8
stand offs for Granddaughter board, six #4-40 Pan-Head screws along with
Front panel face plate package. The Front panel faceplate package includes 3
retainer brackets and six #2-56 flat head screws.
NOTE: Every 6KPM Card package comes with their matching Daughter and
Granddaughter board. The copper 6KPM card should not work properly if
mixed with other Fiber combo 6KPM card packages. Always install the PM
module separately one by one to avoid the mixing
.
Step 2. Remove Chassis Cover
The Magnum 6K25 chassis are combined with top and bottom parts and
assembled together with the help of 22 Philips-head screws. There are 7 screws located