Magnum 6K16V Managed Fiber Switch         Installation and User Guide (06/04)

 

operation” on that port when lit, the F/H LED indicates operation in full-duplex mode 

when ON (half-duplex when OFF), and the blinking ACT LED indicates receiving 

Activity on the port. A fiber cable must be connected into a SFF port and the Link (LK) 

indicator for that port must be ON (indicating there is a powered-up device at the other 

end of the cable) in order for a LK LED to provide valid indications of operating 

conditions on that port. 

 

2.2.2 

Eight-Port Copper Module, 6K8-RJ45

      

The 6K16V’s 8-

port Copper port module, 

model 6K8-RJ45, provides 

eight 10/100Mb switched RJ-

45 ports. The 10/100Mb 

switched ports normally (as a 

default setting) are 

independently N-way auto-

negotiating for operation at 10 or 100Mb speed in full- or half-duplex mode, i.e., each 

independently selects a mode and speed to match the device at the other end of the 

twisted pair cable.  (See Section 4.3 for auto-negotiation details) 

1                    3                   5                 7

/100

LK

10

F/H

ACT

10/100

LK

        2                   4                      6                  8

 H

ACT

F/

 

On the model 6K8-RJ45 module, there are four LEDs for each port, two in the 

connector and two separate.  The LK (Link) LED indicates “ready for operation” on that 

port when lit. The blinking ACT (Activity) LED indicates receiving Activity on that port 

when lit. The 10/100 LED indicates operation at 100Mb speed when ON and at 10 Mb 

speed when OFF (when auto-negotiation is not disabled). The FDX/HDX LED is ON to 

indicate full-duplex operation and OFF to indicate half-duplex mode. A twisted pair 

cable must be connected into an RJ-45 port and the Link (LK) indicator for that port must 

be ON (indicating there is a powered-up device at the other end of the cable) in order for 

a LK LED to provide valid indications of operating conditions on that port.  

Using the 6K16V’s  MNS software, the user may disable auto-negotiation and 

fix the desired operation of each RJ-45 port. MNS Software set-up may  select 10Mb or 

100Mb speed and full- or half-duplex mode per-port as per user requirement. (See 

Magnum 6K16V  MNS Software Manual for details info.). 

 

2.2.3 

Six-Port “4 + 2” Combo Modules, 4@ 10/100 RJ-45 and 2@ 100Mb fiber  

The combo six-port modules are combinations of copper and fiber media, 

 

9

www  GarrettCom  com

.

.

 

Содержание Magnum 6K16V

Страница 1: ...i www GarrettCom com Magnum 6K16V Managed Fiber Switch Hardware Installation and User Guide...

Страница 2: ...ademarks and Personal Hub is a registered trademark of GarrettCom Inc Important The Magnum 6K16V Managed Fiber Switch contains no user serviceable parts Attempted service by unauthorized personnel sha...

Страница 3: ...ul interference in a residential installation This equipment generates uses and can radiate frequency energy and if not installed and used in accordance with the instructions may cause harmful interfe...

Страница 4: ...19 3 2 2 Connecting Fiber Optic SC type Snap In 19 3 2 3 Connecting Single Mode Fiber Optic 19 3 2 4 Connecting Twisted Pair RJ 45 CAT3 CAT5 20 3 2 5 Connecting Twisted Pair CAT5E or better 20 3 2 6...

Страница 5: ...Twisted Pair 10 100Mb 8 Port 44 5 2 10 6KP8 45 2MT MTRJ Small Form Factor 45 5 2 10a 6KP8 45 2LC LC Small Form Factor 46 5 2 11 GBIC SXSC Gigabit fiber 1000Mb mm SC Connector 46 5 2 11a GBIC LXSC Gig...

Страница 6: ...CHES 100 AND 10 MBPS COPPER PORTS WITH OPTIONAL FIBER PORT WITH AUTO NEGOTIATING FULL SWITCHING PERFORMANCE QUAD SERIES FIBER SWITCHES 100 10MBPS FIBER AND COPPER PORTS MIXED SPEED AND MIXED MEDIA TYP...

Страница 7: ...MBINATIONS INCL FIBER ST SC MM SINGLE MODE THE X LINE OF CONFIGURABLE MIXED MEDIA PRODUCTS STACKABLE CONCENTRATORS SNMP OPTIONAL 13 PORTS MINI CONCENTRATORS 7 PORTS REPEATERS 2 PORTS REPEATER PORT MOD...

Страница 8: ...r 100 m 328 ft Shielded twisted pair 150 m 492 ft 10BASE FL multi mode fiber optic 2 km 6 562 ft 10BASE FL single mode fiber optic 10 km 32 810 ft Maximum Standard Fast Ethernet Segment Lengths 10BASE...

Страница 9: ...Request quote Alarm Relay Contacts One NC indicating internal power one NC software controllable Packaging Enclosure Rugged High strength sheet metal Suitable for vertical wall or DIN Rail mounting Di...

Страница 10: ...ault setting is MDI user port Other port specific user settings such as FDX or HDX copper 10 100 speed can be fixed using software commands Agency Approvals UL listed UL60950 cUL CE Emissions meet FCC...

Страница 11: ...iber module w eight 100Mbps mm FX LC connectors 6KP8V SLC SFF Fiber module w eight 100Mbps sgl m FX LC connectors 6KP4V FXSC 2 2 100Mb Fiber module w four 100Mb 2km FX SC connectors 6KP4V FXST 2 2 100...

Страница 12: ...th 1550nm sgl mode SC 40km fiber connector GBIC transceiver module for use in GBPM COTX one LX port with mm SC fiber connector GBIC LXSC70 GBIC transceiver module for use in GBPM xOTX one 1000BASE ZX...

Страница 13: ...led 1 AC Power Cord U S and other 115 VAC only 1 Set of two metal vertical mounting brackets with screws to the case 1 Installation and User Guide this manual 1 Product Registration Card Remove the it...

Страница 14: ...features include non blocking speed on all ports and 802 1p QoS Traffic Prioritization Magnum 6K16Vs are plug and play ready for use as backbone switches where a mix of bursty data traffic and priorit...

Страница 15: ...fiber Fig 2 2 2 SFF Fiber Port Modules 6K8 MTRJ to the left and 6K8 MLC or SLC below In an eight port SFF fiber port module all of the fiber ports are of the same speed 100Mb mode and connector type M...

Страница 16: ...K 2 4 6 8 H ACT F On the model 6K8 RJ45 module there are four LEDs for each port two in the connector and two separate The LK Link LED indicates ready for operation on that port when lit The blinking...

Страница 17: ...e is also the same On Magnum 4 2 Combo modules there are four LED s for each RJ 45 port which indicate status the same as described for the 6K8 RJ45 in Section 2 2 3 above The fiber port s LEDs indica...

Страница 18: ...ater distance may be available as a special order request quote 2 2 6 Gigabit 1000Mbps port modules The Magnum 6K16V offered a wide option Gigabit speed with multiple choice for the modular slot While...

Страница 19: ...ports two priority queues that can be shared across the eight levels of defined packet priorities for application specific priority control by the user through software configuration settings 2 2 7 Fr...

Страница 20: ...revents more frames from entering by forcing a collision signal on all receiving half duplex ports in order to stop incoming traffic 2 2 8 Managed Network Software MNS 6K for Magnum 6K16V Magnum 6K16V...

Страница 21: ...e other is software controllable and will signal user defined software events such as a security violation or an S Ring fault condition Vertical mounting for efficient convection cooling no fans exten...

Страница 22: ...tructure Example 1 Magnum 6K16V Switch for a Industrial application Equipped with lots of useful features hardened enclosure wide spread of AC DC power supply option extended temperature rating qualif...

Страница 23: ...n to BLDG other FIBER Connection SNMP Monitor Main SERVER Magnum Magnum Fiber GARRETT PW Managed Fiber Switch K25 Magnum 6 1 3 5 7 2 TX RX 6 TX LK RX LK A F CT ACT F 10 10 LK F ACT 1 3 5 7 10 10 LK F...

Страница 24: ...ged Fiber with S ring and Link Loss Learn feature easily fulfilled the redundant requirement in a secured and faster reconfiguration time for cable breakup by setting up in a ring topology The Gigabit...

Страница 25: ...3 1 Locating Magnum 6K16V Switches For vertical panel mounting and wall mounting see Section 3 4 For vertical DIN Rail mounting see Section 3 3 For DC power options see Appendix B For Dual Source see...

Страница 26: ...ls you must use the color coded strand on the associated ports at each end of the fiber optic segment 3 Connect the Transmit TX port light colored post on the Magnum PM to the Receive RX port of the r...

Страница 27: ...sensing for either 10 and 100Mb s The following procedure describes how to connect a 10BASE T or 100BASE TX twisted pair segment to the RJ 45 port The procedure is the same for both unshielded and sh...

Страница 28: ...a factory floor industrial environment It is available with optional DIN Rail brackets to mount it securely in a metal factory floor enclosure maintained vertically for proper convection cooling of t...

Страница 29: ...V on a DIN Rail track for proper convection cooling of the unit Note that there is air space in the rear as the 6K126V unit is held out from the rear of the panel by the mounting brackets The 6K16V de...

Страница 30: ...cing for the mounting screws imto the supporting wall or panel is a rectangle 11 89 x 7 85 center to center 3 4 Powering the Magnum 6K16V Managed Fiber Switch The Magnum 6K16V Switches incorporate an...

Страница 31: ...tware Alarm feature with a software configuration command if desired When the Software Alarm is enabled the Form C Normally Closed NC contact is held close during normal software operation A user defi...

Страница 32: ...d from the chassis before attempting to remove and or replace any PM cards Failure to do so may result in damage to the unit and will void the warranty Caution Avoid Static Discharge The port modules...

Страница 33: ...front panel is easily slid out to the front of the chassis base Figure 3 6 1a Removing the Front panel from the unit Caution Be careful not to disturb the power supply Once the front panel is removed...

Страница 34: ...nificant forces from the attached cables See Figure 3 6 1c Figure 3 6 1c Top View 6KPM retaining screws hold Face Plate 3 6 2 Installing 6KPM Cards in the Magnum 6K16V Up to two front mounted 6KPM car...

Страница 35: ...er Board top view of version for 4 copper 10 100 ports Fig 3 6 2d Daughter Board shown upside down with two male latch connectors Step 4 Hold the daughter board with both hands at the end and align th...

Страница 36: ...panel This will maintain proper cooling air flow safety and operation as required by FCC CE and other regulations Step 6 Now screw down the daughter board with 6 440 screws so that it holds the daught...

Страница 37: ...crews for each 6KPM card These screws are used to secure a 6KPM card in position see Figure 3 6 3a Remove the three standoffs holding the Granddaughter board with the chassis The screen faceplate scre...

Страница 38: ...Port area Note For a detailed description of Managed Network Software MNS 6K and Magnum 6K16V Switch configuration for Network Management please refer to Magnum 6K16V Software Manual available on Gar...

Страница 39: ...ltering and Forwarding Each time a packet arrives on one of the switched ports the decision is taken to either filter or to forward the packet Packets whose source and destination addresses are on the...

Страница 40: ...per the IEEE802 3u standard The selection is made via MNS software The factory default setting is for auto negotiation At 10Mb or 100Mb fixed speed the user may select half or full duplex mode by MNS...

Страница 41: ...10 or 100 speed and will default to half duplex at that speed per the IEEE standard General information Auto negotiation per port for 802 3u compliant switches occurs when the devices at both ends of...

Страница 42: ...eration Note When in Half Duplex mode the 6K16V Switch implements a back pressure algorithm on 10 100 Mb ports for flow control That is the switch prevents frames from entering the device by forcing a...

Страница 43: ...00 62 5 125 19 31 12 4 16 5 7 6KPV SLC 100Mb FX Single Mode 15 0 4 1310 9 125 15 28 11 22 GBIC SXSC 1000Mb Multi mode 0 55 1300 62 5 125 50 125 9 5 17 5 5 2 12 5 4 GBIC LXSC10 1000Mb Single mode 10 13...

Страница 44: ...the shipping container should you need to ship any of the PMs separately at a later date In the event there are items missing or damaged contact your supplier If you need to return the unit use the or...

Страница 45: ...per connectivity with the remote device when lit and FDX HDX LED to indicate full duplex mode when lit or half duplex when off The 10 100 LED indicates the speed if the LED is ON 100Mbps if it is OFF...

Страница 46: ...s a special order Each port has an Activity ACT LED indicating packets being received a Link LK LED indicating proper connectivity with the remote device when lit and FDX HDX LED indicating full duple...

Страница 47: ...nd the same face plate lettering 4 Po 6KP6 RJMSC rt 10 100Mbps and 2 100 Mb SC Fiber Port 4 FULL HALF 1 ACTIVITY LINK 2 4 3 3 10 100 1 3 5 7 2 6 TX RX TX LK RX LK ACT F H ACT F H 10 100 LK F H ACT 2 1...

Страница 48: ...Budget Section 4 5 Each port has an Activity ACT LED indicating packets being received a Link LK LED indicating proper connectivity with the remote device when lit and a FDX HDX LED indicating full d...

Страница 49: ...mode 8 Port module is essentially the same as the ST and SC types It has the same LEDs per port indicating port activity ACT Link LK and FDX or HDX operation 5 2 5a 6KP6 MT10ST 4 100Mb multi mode FX...

Страница 50: ...HALF 1 ACTIVITY LINK 2 3 10 100 5 2 7 6KP8 MLC 8 ports 100Mbps multi mode LC connector Small Form Factor Magnum 6KP8 MLC is a eight port multi mode fiber LC connector small form factor used primarily...

Страница 51: ...ACT F H ACT F H 2 ACT F H ACT F H 6KP8 45LC 4 Port 10 100Mbps 4 port 100Mbps Multi Mode LC Fiber port 1 3 5 7 10 100 LK 1 F H ACT 4 FULL HALF 1 ACTIVITY LINK 2 3 10 100 5 2 9 6KP8 RJ45 Twisted Pair 1...

Страница 52: ...5 2 c RJ 45 module at page no 27 The RJ 45 pins normally TP crossover switch are per the standard for hubs to users twisted pair wiring 1 receive 2 receive 3 transmit 6 transmit other pins not used Wh...

Страница 53: ...ipped with SC type connectors and can be easily snapped in and out The Gigabit fiber ports are most popular as server to switch and switch to switch applications It supports cable distances up to the...

Страница 54: ...supports cable distances up to the IEEE 802 3z standard 1000Mbps distance limits i e 10 25 40 or 70Km at full duplex and depend upon the Gigabit modules used TX RX L ACT F TX RX LK ACT F TX LK RX ACT...

Страница 55: ...ection of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable 2 Check the cables and connectors to ensure that they have been pro...

Страница 56: ...s and printers plus the various network media types being used 4 A record of changes that have been made to your network configuration prior to the occurrence of the problem Any changes to system admi...

Страница 57: ...corn type packing material This material may cause electro static shock damage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the shipping container 3 Garret...

Страница 58: ...45 ports Input current 2 4Amps max for all Fiber ports Input Voltage 36 to 70 VDC 48VDC Input current 0 8Amps max for all RJ 45 ports Input current 1 2Amps max for all Fiber ports Input Voltage 115 to...

Страница 59: ...gement and operations monitoring equipment The 24V and 125VDC options are particularly useful in the Industrial environment where it is common for facilities to operate on 24VDC or 125VDC power The 12...

Страница 60: ...a earthing wiring 3 Use only with Listed 10 A circuit breaker provided in building installation 4 Complies with FDA radiation performance standards 21 CFR subchapter J or equivalent 5 Fastening torque...

Страница 61: ...n are identical to those listed in the Magnum 6K16V Fiber Switches Installation and User Guide including Appendix B Internal DC Power Supply Option C2 0 MAGNUM 6K16V with 48VDC 24VDC and 125VDC Dual S...

Страница 62: ...h shown in Figure The 48VDC terminal block on the Magnum 6K16V Switch as shown in Fig C5 0 is located on the right rear of the unit and is equipped with five 5 screw down lead posts If it is the rever...

Страница 63: ...at least 4 inches apart with the first one located within 6 inches of the terminal block C6 0 ORDERING INFORMATION To order the optional Dual Source 48VDC power supply factory installed order Dual Sr...

Отзывы: