Magnum 4K220 Switches  Installation and User Guide      (10/04) 

 

22 

www  GarrettCom  com

.

.

 

networking solution utilizing a special power supply in hubs with a proven track record.  
 

The –48VDC solution is particularly useful in the telecommunication 

industry, where it is common for facilities to operate on -48VDC power. Such 
companies include regular and wireless telephone service providers, Internet Service 
Providers (ISPs) and other communication companies.  In addition, many high 
availability equipment services, such as broadcasters, publishers, newspaper operations, 
brokerage firms and other facilities often use a battery backup system to maintain 
operations in the event of a power failure. It is also frequently used for computer system 
backup, management and operations monitoring equipment. 
 

 

The 24VDC & 125VDC solution are particularly useful in the 

Industrial environment, where it is common facilities to operate on 24VDC & 125VDC 
power. The 125VDC solution is  mainly used in Utilities Industries, such as Electric 
substation, Electrical generating plant etc. Whereas 24VDC application is mainly in the 
Industrial environment, such as chemical plants, paper mill, stone quarrying plant, 
wastewater treatment Plant etc. 

 

 

B4.0 INSTALLATION 

 

 

This section describes the installation of the -48 VDC, 24VDC & 125VDC 

power source leads to the -48 VDC, 24VDC & 125VDC power terminal block on the 

Magnum 4Ks. (see figure below). 

 

 

Figure B4.1:  -48VDC Terminal 

Block on Magnum 4Ks-48VDC 

 

 

 

 

The -48VDC terminal 

block on the Magnum Ks is 

located on the rear of the unit and 

is equipped with three (3) screw-down lead posts and it is similar for 24VDC and 

125VDC Magnum 4Ks too.  The leads are identified as negative (-), positive (+), and 

chassis ground (GND).  The actual connection procedure is very straightforward.  

Simply connect the leads to the Magnum unit, beginning with ground.  Ensure that each 

lead is securely tightened. 

Note: Before connecting to Terminal Block of –48VDC, 24VDC or 125VDC,  always 
use a digital voltmeter to measure the output voltage of the power supply and 
determine the lead which is  more  “+ve potential Lead”. The more “+ve” voltage 
terminal lead from 48V  or –48V Power supply must be connected to the post labeled 
“+”. 
The GND can be hooked at the last. 

 

36-70VDC

_

+

GND

ON

OFF

Содержание Magnum 4K220

Страница 1: ...25 27 29 31 33 35 37 39 115 230V 50 60 Hz GND 48V DC X UPLINK 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 Power Col FDX Col FDX Magnu...

Страница 2: ...sonal Switch are trademarks and Personal Hub is a registered trademark of GarrettCom Inc Important The Magnum 4K220 Switches contains no user serviceable parts Attempted service by unauthorized person...

Страница 3: ...frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio communication It has been tested and found to...

Страница 4: ...ALITY 14 4 2 STATUS LEDS 15 4 3 UP LINK PORT FOR RJ 45 PORT 39 ONLY 15 4 4 AUTO NEGOTIATION FOR RJ 45 COPPER PORTS 15 4 5 AUTO NEGOTIATION FULL DUPLEX MODE 16 4 6 FLOW CONTROL IEEE 802 3X STANDARD 17...

Страница 5: ...100 and 2 100Mb fiber ports can be connected in strings Mixed Media Fiber Hub 16 port Stackable 10 100 auto sensing Dual Speed 8 port and 16 port Stackables 10 100 auto sensing Stackable Hubs SNMP Op...

Страница 6: ...pair 100 m 328 ft Shielded twisted pair 150 m 492 ft 10BASE FL multi mode fiber optic 2 km 6 562 ft 10BASE FL single mode fiber optic 10 km 32 810 ft Maximum Standard 100Mb Fast Ethernet Segment Lengt...

Страница 7: ...upply Internal AC Power Connector IEC type male recessed at rear of chassis with adjacent manual ON OFF switch on AC models only Input Voltage 110 to 240 VAC auto ranging Input Frequency 47 to 63 Hz a...

Страница 8: ...ord U S and other 115 VAC only 1 Set of metal Ears for standard 19 rack mounting 1 Installation and User Guide this manual 1 Product Registration Card Remove the items from the shipping container Be s...

Страница 9: ...ability to the larger network The 40 port density in a 1U rack mount reverse package is obtained by dedicating the front of the unit to the LED indicators and the rear side of the unit to wiring and p...

Страница 10: ...ith its own switched 100Mbps or 10Mbps domain The 4K220CR may be equipped with an optional internal 48VDC power supply See Appendix A There is an additional option of a dual source 48V input See Appen...

Страница 11: ...rts are independently N way auto negotiating for operation at 10 or 100Mb speed in full or half duplex mode as a default setting They independently move to half duplex mode at 10 Mb or at 100Mb speed...

Страница 12: ...esulting in a small fixed number of packets to be stored per port When the port buffer fills up dropped packets may result This dynamic buffer allocation provides the capability for the maximum resour...

Страница 13: ...in the Switch before it is sent along or forwarded to its destination of the 4K220 Switches varies with the port speed types and the length of the frame is a variable here as it is with all store and...

Страница 14: ...e package with LEDs in front and all wiring and cables in the rear Plug and Play installation for high performance switching Magnum 4K220 Switches are self learning for node addresses They can be plac...

Страница 15: ...Example1 In a setup for a typical small office a central Switch is needed to provide for a 40 segment 100Mb Fast Ethernet LAN with switched copper support for 3 high speed local servers for different...

Страница 16: ...and the shield is grounded at both ends Installation This section describes installation of the Magnum 4K Series Switches as well as connection of the various Ethernet media types 3 1 Locating Magnum...

Страница 17: ...J 45 NOTE It is recommended that high quality CAT 5 cables which work for both 10 Mb and 100Mb be used whenever possible in order to provide flexibility in a mixed speed network since dual speed ports...

Страница 18: ...rack or a 23 rack is a simple procedure The units are 1U 1 75 high When properly installed the front mounted LED status indicators should be in plain view and easy to read Rack mount installation requ...

Страница 19: ...orward the packet Packets whose source and destination addresses are on the same port segment will be filtered constraining them to that one port and relieving the rest of the network from processing...

Страница 20: ...port 39 in the X port for cross over or up link segment connections to a repeater or hub or switch Verify proper port connection by noting the port s LINK ACT status which is illuminated when a proper...

Страница 21: ...or all devices and cable lengths within that domain For Magnum 4K Series switched ports operating at 100Mb half duplex the bit time delay is 50BT 4 5 Auto negotiation full duplex mode Full duplex Ethe...

Страница 22: ...t sending the packets Of course the transmitting device must also support the 802 3x flow control standard in order to communicate properly during normal operation Note When in Half Duplex mode the 4K...

Страница 23: ...is isolated to a network device other than the Magnum 4K220 product it is recommended that the problem device is replaced with a known good device Verify whether or not the problem is corrected If not...

Страница 24: ...m com When calling please have the following information readily available Name and phone number of your contact person Name of your company institution Your shipping address Product name Serial Numbe...

Страница 25: ...tCom Inc 47823 Westinghouse Drive Fremont CA 94539 Attn Customer Service APPENDIX A WARRANTY INFORMATION GarrettCom Inc warrants its products to be free from defects in materials and workmanship for a...

Страница 26: ...dentical to those listed in the main manual B2 0 48VDC 24VDC 125VDC POWER OPTION THEORY OF OPERATION The 48VDC 24VDC 125VDC power option are designed using diodes inside on each DC power input line be...

Страница 27: ...Electrical generating plant etc Whereas 24VDC application is mainly in the Industrial environment such as chemical plants paper mill stone quarrying plant wastewater treatment Plant etc B4 0 INSTALLA...

Страница 28: ...le to the rack at least 4 inches apart with the first one located within 6 inches of the terminal block B5 0 OPERATION Operation of the Magnum 4Ks with the optional 48VDC 24VDC 125VDC power supply is...

Страница 29: ...earth or ground wire connection to the hub chassis Input Two separate sources each at 120 160 VDC auto ranging Power Consumption Model 4K220 28 watt typical 35 watts max With the exception of the dual...

Страница 30: ...nor will it blow the fuse in the internal power supply because of the blocking action of the diodes This is true even if one input connection is reversed while the Switch is operating from the other...

Страница 31: ...zed DC Power Source cable securement use at least four cable ties to secure the cable to the rack at least 4 inches apart with the first one located within 6 inches of the terminal block C6 0 ORDERING...