10.

MAINTENANCE & REPAIR

10.1.

PERIODIC MAINTENANCE

Periodic maintenance requires that you inspect for loose or damaged parts and clean
the surface of the PD 6500’s exterior. The following procedure is recommended:

1

. Open the access door of  the detection unit and ensure that the connectors are

snapped securely and the screws and nuts are in place.

2

. Inspect the windows of the IR sensor to ensure they are not blocked.

3

. Ensure that the eight screws that attach the crosspiece and detection unit to the 

panels are in place and tight.

4

. Ensure that the archway sits flat on the floor and does not sway or rock.

5

. Ensure that there the power cord and cable to remote devices are neither frayed nor

broken. If necessary, replace immediately.

6

. Clean exterior surfaces with mild soap and water only. Use only denatured alcohol

for heavy-duty cleaning.

10.2.

REPAIR

The Magnascanner’s modular design facilitates assembly and maintenance. 

If problems are site-related, see Section 3.1 or contact the factory for assistance. Often,
adjusting or relocating the equipment, or removing nearby objects resolves problems.

If the equipment does not perform properly, contact your dealer or the factory 
for assistance. 

10.3.

MODULE REPLACEMENT

The system comprises a series of removable and replaceable modules that are tested
and calibrated independently, thereby eliminating the need for adjustments to the elec-
tronic assembly.

However, after any component is replaced, 

the system must be tested thoroughly 

to

confirm that the PD 6500 operates properly.

27

MAGNASCANNER PD 6500

OWNER’S MANUAL

©2000 GARRETT METAL DETECTORS, INC.
6/19/00

PN 1531100

Содержание MAGNASCANNER PD 6500

Страница 1: ...OWNER S MANUAL MAGNASCANNER PD 6500 MODEL 11678XX Garrett Metal Detectors Inc 1881 W State Street Garland TX 75042 6797 972 494 6151 Fax 972 494 1881 email security garrett com www garrett com 6 19 00...

Страница 2: ...STMENTS 17 7 SUPERVISOR RESPONSIBILITIES 19 8 OPERATOR RESPONSIBILITIES 20 9 TECHNICAL SPECIFICATIONS 22 10 MAINTENANCE REPAIR 10 1 PERIODIC MAINTENANCE 27 10 2 REPAIR 27 10 3 MODULE REPLACEMENT 27 10...

Страница 3: ...will trigger bar graph activity CAUTION PD 6500 must be firmly anchored to the floor or optional stabilizer base attached to reduce the risk of injury to persons or property damage due to accidental k...

Страница 4: ...arrays that help the operator identify the precise location of a metal object whether it is on the left right or in the center of the body or from head to toe An LCD located in the overhead panel and...

Страница 5: ...2 1 4 LCD LIQUID CRYSTAL DISPLAY The LCD is an ongoing visual display located in the overhead panel The LCD reports calibration and operational information including program and sensitivity settings o...

Страница 6: ...ady to resume full operation 2 2 3 COUNTER The COUNTER touchpad is used to obtain an automatic update on the traffic count that appears on the LCD To return the traffic count to zero press and hold th...

Страница 7: ...on the LCD for five seconds An asterisk appears on the sequence counter indicating an unsuccessful attempt to access the program base sensitivity settings or the Installation mode If the ACCESS touch...

Страница 8: ...the controller module containing the top circuit board middle circuit board and the transmitter control board and the power module See Figure 2 5 MAGNASCANNER PD 6500 OWNER S MANUAL 2000 GARRETT METAL...

Страница 9: ...els are plugged into connectors at the top of each panel The controller module cover should not be removed except in order to Connect wires to remote alarm relays or synchronization circuitry See Sect...

Страница 10: ...y bumping against the detector wall and blaming the alarm on the bump Therefore if an alarm sounds when a person is passing through the archway he she must re enter the PD 6500 and or be scanned with...

Страница 11: ...e 1 4 mounting holes located at the base of each panel Position the PD 6500 in the desired location Using the panels as guides mark and drill the holes then secure the walk through using the appropria...

Страница 12: ...mper cord has been connected 6 Use the four remaining screws and washers to attach the crosspiece to the two panels as shown in Figure 3 4 7 Use two or more people to lift PD 6500 to a vertical posi t...

Страница 13: ...a problem a failure message will appear e g SYNC FAIL Refer to Table 4 1 for a list of possible failures and remedies 4 2 1 CRITICAL FAILURES AND NON CRITICAL FAILURES Failures are classified as eithe...

Страница 14: ...of archway POWER MOD FAIL Power module Ensure line voltage is between 100 and 240 VAC RXA BOARD FAIL 40 pin cable connection to top board and top board cable RXB BOARD FAIL 40 pin cable connection to...

Страница 15: ...large metal object adjacent to the PD 6500 Then ensure that the balance number has fallen below 50 and the corresponding pinpoint lights are off Press ACCESS for the next adjustment or OPERATE to res...

Страница 16: ...e 1 is set to the base sensitivity ZONE 1 165 15 Zone 1 sensitivity is 15 greater than the base sensitivity ZONE 1 165 15 Zone 1 sensitivity is 15 less than the base sensitivity Press ACCESS for the n...

Страница 17: ...f video terminals including x ray monitors computers and closed circuit televisions Use the and touchpads to select from 63 filter settings If you observe noise at the desired base sensitivity setting...

Страница 18: ...E ENTERED OK should appear If the message INVALID ENTRY appears repeat steps 2 and 3 NOTE To revert to factory settings 1 Open the main cover of the detection unit 2 Remove the three screws attached t...

Страница 19: ...the needs of the screening installation For example when you select PROG AIRPORTS the PD 6500 detects guns but elimi nates certain metal objects from detection in this case innocuous items such as ke...

Страница 20: ...etting that triggers an alarm 8 Once you are satisfied that you have performed enough tests i e an alarm sounds each time you pass the OTP through the metal detector choose the lowest setting that det...

Страница 21: ...s the base sensitivity To confirm that the new base sensitivity setting is appro priate test the OTP at varying locations and orientations within the walk through partic ularly in spots where you susp...

Страница 22: ...ly The test should complement your overall secu rity plan and be performed daily Pass an OTP and or other objects at varying locations and orientations within the archway Note the number of repetition...

Страница 23: ...f the self test reveals a failure that severely limits or prohibits the PD 6500 s perfor mance the alarm will sound the LED display will flash and the message SYSTEM FAILURE will appear on the LCD The...

Страница 24: ...omplete horizontal and vertical uniformity The sensitivity of each field can be adjusted to meet the requirements of specific secu rity applications The PD 6500 s unique design enables the operator to...

Страница 25: ...ted on the side panels of the exit side help the operator to identify the precise location of a metal object within the walk through whether it is on the left center or right side of the body or from...

Страница 26: ...atly reduces the occurence of nuisance alarms by inhibiting alarm activity without a person in the archway In circumstances where large metal objects such as luggage or supply carts and x ray equipmen...

Страница 27: ...FEATURES 2225400 Dual battery back up permits approximately eight hours of operation with quick recharge 12 hours maximum 1168000 Magna Dolly wheel assembly for easy portability 9 24 WEIGHT 126 lbs 9...

Страница 28: ...Through Metal Detectors for Use in Weapons Detection NILECJ STD 0601 00 sec tion 4 11 Canada Health and Welfare Performance Standards walk through RPB SC 18 section 3 2 2 which addresses the issue of...

Страница 29: ...sary replace immediately 6 Clean exterior surfaces with mild soap and water only Use only denatured alcohol for heavy duty cleaning 10 2 REPAIR The Magnascanner s modular design facilitates assembly a...

Страница 30: ...28 MAGNASCANNER PD 6500 OWNER S MANUAL 2000 GARRETT METAL DETECTORS INC 6 19 00 PN 1531100 Figure 10 1 Figure 10 2 CONTROLLER MODULE DETECTION UNIT...

Страница 31: ...29 MAGNASCANNER PD 6500 OWNER S MANUAL 2000 GARRETT METAL DETECTORS INC 6 19 00 PN 1531100 Figure 10 3 Figure 10 4 Figure 10 5...

Страница 32: ...y B Det Unit Long 2417200 1 14 Power Cord Euro Plug 9421300 1 15 Power Cord 110V 10 9411500 1 16 Touchpanel 9425100 1 17 Ribbon Cable 40x3 5 Tx Rx 2416800 2 18 Ribbon Cable 12x44 Light Bar 2416900 2...

Страница 33: ...essed or implied including the warranty of merchantability or fitness for a particular purpose The Buyer acknowledges that any oral statements about the merchandise described in this contract made by...

Страница 34: ...00 OWNER S MANUAL 2000 GARRETT METAL DETECTORS INC 6 19 00 PN 1531100 11 ADDITIONAL INFORMATION 11 1 OPERATIONS WORK SHEET Location Serial Number Version Date Seq Number Prog Base Sens Settings Change...

Страница 35: ...one to six are used to detect metals ranging from conduc tive and or non ferrous to non conductive and or ferrous respectively Loss Prev1 is designed to detect all metals particularly good conductors...

Страница 36: ...to Loss Prev6 11 2 PROGRAMS CONT D Alternate For use as an alternative under difficult environmental conditions including electri cal interference A general weapons pro gram that provides moderate dis...

Страница 37: ...ing examples are aimed to help the installer determine an appropriate method 11 3 1 CASE 1 Description Two or more PD 6500s that interfere with each other Both units plugged into the same AC power li...

Страница 38: ...Set the remaining units to CHANNEL 2 and 3 as shown 10 Repeat pattern of channels 1 2 and 3 for any additional PD 6500s 11 3 3 CASE 3 Description PD 6500 s that interfere s with MT 5500 s MT 5500 must...

Страница 39: ...nect power 11 5 BATTERY PACK MODULE OPTIONAL The battery pack module is a field installable assem bly that provides approximately eight hours of uninter rupted operation A monitoring circuit ensures t...

Страница 40: ...To replace or remove plug or to hard wire to an AC junction box use Green to ground Black to line hot White to line neutral MAGNASCANNER PD 6500 1167720 INTERNATIONAL Includes a European power cord To...

Страница 41: ...n the center of a persons body activates pinpoint lights on BOTH sides of the archway A weapon located either on the right or left side of the body activates pinpoint lights on the right OR left side...

Страница 42: ...Copyright 2001 Garrett Metal Detectors All rights reserved PN 1531100 0600...

Отзывы: