background image

USER MANUAL

Service / Maintenance

The service must be performed by a professional electrician.
A service form can be found at https://www.garo.se/en/volvo-trucks/manuals

In order for the warranty to apply, it is required that a completed service form/forms, (depending on the age of the product), can be 
presented when contacting Volvo Action Service.

The most recent service form may not be older than 12 months. Service is performed by visual inspecting both outside and inside of the 
LS4 MINI, conditioning of components as well as functional tests. Specific service points can be found in the service form. 

If your LS4 MINI is connected to Backend Operator or other external supervised system, GARO recommends that you contact the 
operator, to plan the service in advance, in order to avoid unnecessary errors and warning messages that could lead to expensive 
emergency call outs from other service partners. You can normally find information inside the LS4 MINI if it is connected to a supervised 
system. 

Service and maintenance form

Check point for annual maintenence:

Status/ Value

Comment/remark

Visual check outside cabinet
LED indication lit
Check cables, connectors, connector pins 
Check color, foil and instructions
Check fastening/fixing to ground/wall
Clean LS4 MINI outside surface
Check both RCCB by pressing "T" button. Check that LED indication 
switches to red color for both sides
Function test by GARO test-equipment or similar
Check that electrical power is delivered by indications on  test equipment
Check RFID reader (when available). Indication by 2 or 3 flashes from 
LED:s

Turn off the electrical power

Check gaskets
Check torque for mains terminals
Check torque for LS4 MINI fixing screws towards ground/wall
Check connectors on CCU module
Check torque for connectors on contactor, relays, and DC-PSU
Measure the earthing resistans (Ohm) on EV sockets/cables with a 
multimeter
Clean inside when necessary

Turn on the electrical power

Check charging function

Plant ID:

Name:

Date:

13

EN

Содержание LS4 MINI

Страница 1: ...LS4 MINI Box 203 SE 335 25 Gnosjö Phone 46 0 370 33 28 00 info garo se garo se Manual 380285 1 0 Assembly instructions End User Instructions EN GARO AB EN ...

Страница 2: ...ORMATION 3 Warnings 3 Cautions 4 Notes 4 Content 4 INSTALLATION 5 USER MANUAL 7 Normal use 7 LED indications 7 Dimensional sketch 11 Technical specifications 12 Service Maintenance 13 Service and maintenance form 13 Installation Form 14 2 EN ...

Страница 3: ...ear flammable explosive harsh or combustible materials chemicals or vapors Turn off the electrical power at the circuit breaker before installing configuring cleaning or maintenance Use LS4 MINI only within the specified parameters Never spray water or any other liquid directly at LS4 MINI Never spray any liquid onto the charge handle or submerge the charge handle in liquid Store the charge handle...

Страница 4: ... any questions please contact your local electrical authority Ensure that the charging cable is positioned so it will not be stepped on driven over tripped on or subjected to damage or stress Unroll the charging cable to prevent it from overheating Do not use cleaning solvents to clean any of the components The outside of the LS4 MINI the charging cable and the end of the charging cable should be ...

Страница 5: ...fuse and cable information in the Installation form located in the installation manual that is included in the box 3 Mount the LS4 MINI on a wall or on a pedestal figure 1 6 Note Wall installation requires a minimum 20mm distance between the wall and the LS4 MINI to ensure correct cooling figure 4 Recommendation is to use the included wallbracket 4 Install the electric supply cable L1 L2 L3 and N ...

Страница 6: ...ALLATION CU L1 L2 L3 N 6Nm PE 2 5 10mm 5Nm 16 50mm 10Nm AL L1 L2 L3 N 2 5 16mm 5Nm 25 50mm 10Nm PE 2 5 10mm 5Nm 16 50mm 10Nm Pedestal Accessory 0 8Nm 0 05 figure 4 figure 5 figure 3 4x ALU CU adapters 6 EN ...

Страница 7: ...ng station detects that the cable is connected but is yet to detect the EV Blinking green 30 second blink Whenever during operation Charging station have received command from backend to start charging and is waiting for EV to connect Firm blue EV connected Charging is ongoing state C EV connected Charging is paused state B Blinking blue Whenever during operation Charging station point is reserved...

Страница 8: ...is connected correctly Check the intake on the EV for obstructions dirt Firm blue No error Have you tried everything without success Contact Your retailer and as 2nd option contact Volvo Action Service please have M number available No error Blinking blue No error contact backend operator if this is not the desired mode Blinking yellow When RFID is presented Charging station is verifying the RFID ...

Страница 9: ... current in backend charger configuration OperatorCurrentLimit Check motor locking wiring and connection for damages Verify that locking mechanism rod and arm are not stuck Verify that the connector is properly inserted into the socket Light force may be applied Verify that there are no foreign objects inside the socket inlet on the EV hence blocking the connector Check charging cable and connecto...

Страница 10: ... unit delivers 12DC on the output terminals when red black cables were disconnected then it has detected an earth fault in one of the DC powered components controllers upper PCB router switch etc inside the charging station If LED light DC OK remains turned off consider replacing the 12V power supply unit Check red black cable and connection between DC terminal and upper PCB quick connection locat...

Страница 11: ... AUTHORIZED available A Vehicle not connected Firm blue CHARGING occupied C Vehicle connected ready CHARGING suspendedEV B Vehicle connected not ready Blinking blue Reserved Firm red RCD triggered groundFailure Residual current detected via sensor groundFailure MCB of type 2 socket triggered overCurrentFailure Actuator unlocked while charging connectorLockFailure Plug locking failed on the EV side...

Страница 12: ...arging type Mode 3 Charging method AC Charging Protection class IP44 Mechanical impact resistance IK10 Temperature range 25C 40C Weight 25kg Standard cable length 7 5m Rated current withstand 10kA Rated short time withstand current 10kA Rated conditional short circuit current of an assembly 10kA Rated impulse withstand voltage 4kV Rated insulation voltage 230 400V Rated current 63A Rated diversity...

Страница 13: ...artners You can normally find information inside the LS4 MINI if it is connected to a supervised system Service and maintenance form Check point for annual maintenence Status Value Comment remark Visual check outside cabinet LED indication lit Check cables connectors connector pins Check color foil and instructions Check fastening fixing to ground wall Clean LS4 MINI outside surface Check both RCC...

Страница 14: ...NUAL Installation Form LS4 MINI Model M nr ELECTRICAL INSTALLATION DATA Group fuse A Supply cable dimension FUNCTION TEST Testbox Date Sign Installer Company Name Owner Customer Name Installation address 14 EN ...

Страница 15: ...GARO AB Box 203 SE 335 25 Gnosjö Phone 46 0 370 33 28 00 info garo se garo se EN ...

Отзывы: