Before setup
Before deciding the connection type between several
charging stations (CS), decide the internet connection
type for the master CS. Refer to
The system is equipped with a built-in meshed Wi-Fi
system that contributes to an easy installation. However,
large distances or radio obstacles may require physical
ethernet cable connections. Cable connection is a good
recommendation, but comes with pros and cons. The
first charging station unit must be setup as a master unit.
Other charging station units can be connected to the
master unit using mesh Wi-Fi, ethernet cable or both.
The master charging station unit is the bridge between
the mesh Wi-Fi and the ethernet cable. It is not possible
to switch between Wi-Fi and ethernet without assigning
a charging station as a master unit. Each internet
connection type must be set up through a master unit.
NOTE
If DLM is used, all charging stations must be on the same
network.
NOTE
Number of units in a connection group is limited to 32.
If more units are needed, then subgroups needs to be
used.
Create and setup a load interface
1. Create a unit, add a name for it and select GARO
Entity Balance.