4. Use a Torx TX20 and tighten the 6 screws until the
charging unit is tight against the installation bracket
(max. 2,9 Nm).
CAUTION
Do not overtighten the screws.
5. Set the power to on.
WARNING
Electrical power can cause serious personal injury or
death.
NOTE
If the charging station needs manual internet settings, e.
g. if it shall act as master with a local Wi-Fi as the
internet connection, then at this time the internet
connectivity settings in the GARO Connect app should
be made. Refer to
Create and setup a load interface,
4.12.15 TO DO A FINAL FUNCTIONALITY TEST OF
THE PRODUCT
CAUTION
If the charging unit needs reduced installed current
settings, make sure this setting done before testing with
high power, such as EV charging.
1. Switch the power/voltage to off.
T20
O OFF
O OFF
O OFF
O OFF
36
Содержание ENTITY PRO
Страница 1: ...GAROEntityProinstallationand operation GARO Entity Pro installation and operation...
Страница 4: ......
Страница 8: ......
Страница 10: ......
Страница 74: ......
Страница 84: ......
Страница 90: ......
Страница 91: ...EC DECLARATION OF CONFORMITY 91 EC Declaration of conformity...