Garnet SPILLSTOP 815 Скачать руководство пользователя страница 1

Page 1

815 Manual

Printed in Canada

www.garnetinstruments.com

TM

S

PILL

S

TOP

Overfill Prevention System

MODEL 815 MANUAL

Содержание SPILLSTOP 815

Страница 1: ...Page 1 815 Manual Printed in Canada www garnetinstruments com TM SPILLSTOP Overfill Prevention System MODEL 815 MANUAL ...

Страница 2: ...TURES AND OPERATION 4 CHAPTER 3 INSTALLATION GUIDE 7 CHAPTER 4 WIRING DIAGRAMS 11 CHAPTER 5 TROUBLESHOOTING GUIDE 12 CHAPTER 6 SERVICE AND WARRANTY INFORMATION 13 MAIL IN WARRANTY 15 GARNET SPILLSTOP Overfill Prevention System MODEL 815 MANUAL 815 Manual_v4 0 25 Jan 18 TM ...

Страница 3: ...t that the operator is unable to shut down loading when the tank is full The 815 is easy to install and operate and is designed to withstand the rigors of mobile applications It consists of a truck mounted controller and a small module that inserts into the SEELEVEL gauge the module is built in to the SEELEVEL SPECIAL gauge An optional indicator is available to verify proper plug connections for t...

Страница 4: ...inside the SeeLeveL truck gauge the gauge module is built into the 808P2 and 810PS2 displays The gauge module installs inside the SeeLeveL gauge display and converts the alarm signals from alarms 1 2 and 3 in the SeeLeveL gauge to a pulse signal that is sent along a single wire to the controller The plug module monitors the signal between the gauge module and the controller and turns on the SpillS...

Страница 5: ...e possible operator error of forgetting to re arm If the tank is not filled to the alarm point the system can still be bypassed to prevent sloshing from sounding the horn or shutting down the engine during driving If a single tank is to be filled from more than one location the alarms can be bypassed during driving between loading sites and the system re armed with the MANUAL RE ARM switch to re e...

Страница 6: ...be damaged by short circuits or by plugging the trailer light plug into the SpillStop socket The controller will operate at truck voltages from 8 to 16 volts and draws less than 1 4 amp so it can operate from any convenient 12 volt circuit ...

Страница 7: ...auge module signal wire will connect to the SpillStop compartment terminal If an 808PA SeeLeveL Special is being used rather than an 810PS SeeLeveL no gauge module is required since it is built into the SeeLeveL Special display where the signal wire is the GREEN wire If you are connecting a gauge module to an older 810 SeeLeveL with a terminal block mounted on a circuit board in the base of the bo...

Страница 8: ...erminal to the wire from gauge 1 and to one of the GREY plug module wires d Green socket terminal to the wire from gauge 2 and to one of the GREY plug module wires e Red socket terminal to the wire from gauge 3 and to one of the GREY plug module wires f Yellow socket terminal to the wire from gauge 4 and to one of the GREY plug module wires Note If there are left over GREY plug module wires connec...

Страница 9: ...k Break the connection to the switch and connect the two wire ends to the contact terminals 30 87 of the auxiliary ESD relay supplied Connect one of the auxiliary ESD relay coil terminals 86 to ground and the other coil terminal 85 to the remaining SHUTDOWN terminal on the SpillStop controller It is a good idea to mount the auxiliary ESD relay close to the existing shutoff wiring to minimize any e...

Страница 10: ...ue Ensure that this value and the empty reading are recorded in the provided area in the operator s manual The truck operator must be given the owners manual upon delivery with all front page data filled in 9 Put the covers back on the SeeLeveL gauges and test the system for proper operation by lifting the float s As the float is raised the horn should turn on first and then the engine or hydrauli...

Страница 11: ...PRESSURE SWITCH CLOSED WHEN PTO ENGAGED 85 86 30 87 PTO SENSE RELAY COIL CONTACTS 87A NOTE Relay contacts 30 and 87A are the normally closed NC contacts Relay contacts 30 and 87 are the normally open NO contacts TO FUEL SHUTOFF FROM HORN Use Brake Light Switch Existing Ground Existing Ground Use blue wire for this circuit This must be a dedicated line unshared Note 1 Use 12 gauge wire on this circ...

Страница 12: ...to see if the rest of the system is working If the engine will not start ground the green wire from the controller If the engine still does not start the problem is in the relay or associated wiring If the engine now starts and the controller indicates no shutdown alarm or is bypassed then the controller is bad If the horn will not sound ground the orange wire from the controller If the horn still...

Страница 13: ...arnet factory specifications LIMITATION ON WARRANTIES These warranties are the only warranties expressed or implied upon which products are sold by Garnet and Garnet makes no warranty of merchantability or fitness for any particular purpose in respect to the products sold Garnet products or parts thereof assumed to be defective by the purchaser within the stipulated warranty period should be retur...

Страница 14: ......

Страница 15: ... IT IS DIFFICULT TO DETERMINE WARRANTY VALIDITY DEALERS NAME WARRANTY CONTACT ADDRESS TELEPHONE FAX IN UNITED STATES RETURN TO Garnet Technologies Inc 201 M M Ranch Road Granbury TX 76049 USA IMPORTANT RETURNING THIS CARD WILL ENABLE US TO NOTIFY YOU IN THE EVENT OF A PRODUCT RECALL OR TO SUPPLY YOU WITH REQUIRED PRODUCT SAFETY INFORMATION TO MAXIMIZE YOUR WARRANTY PLEASE REGISTER ONLINE AT www ga...

Страница 16: ......

Страница 17: ......

Страница 18: ...nts com CANADA Garnet Instruments Ltd 286 Kaska Road Sherwood Park AB T8A 4G7 USA Garnet Technologies Inc 201 M M Ranch Road Granbury TX 76049 P 780 467 1010 F 780 467 1567 TF 1 800 617 7384 P 817 578 8601 F 817 573 0005 TF 1 877 668 7813 ...