Page 15
900D4D Manual
previous code reappears. If the number of digits is correct,
then “
Stor
” will be shown momentarily and the new code will
be stored.
5. COPY MENU:
To access the copy menu, press ↓↓
FAST
DOWN
until the display shows “
COPY
“. This allows remote
copying or programming by releasing control of the memory
so that the 900M remote programmer can access it.
6. Follow the directions for the remote programmer to perform
the desired functions. The gauge will stay in this mode for
about 3 minutes, and will automatically return to normal
operation if no button is pressed. If more time is needed
then press any number button before the 3 minutes is up to
reset the timer.
7. OFFSET MENU:
The display must be connected to the sender
bar in order to set the offset. To access the offset menu, press
↑↑
FAST UP
or ↓↓
FAST DOWN
until the top left display shows
“
OFFS
”. The top right display will show “
XXX.X
” which is the
fluid level in inches using the existing offset programmed into
the display, and the lower displays will show the number of
inches the bar output is changed to obtain the proper fluid
level (this number can be positive or negative). This bottom
number is for reference only; it is never shown during normal
operation. If the top right display shows “
tohi
” then the fluid
level has been set to over 960 inches, which is taller than the
tallest possible sender bar.
8.
Determine where to set the offset. If the tank is empty,
measure from the bottom of the tank to the middle of the
vertical part of the float (for interface displays measure to
the top float, making sure that there is at least two inches
between the floats). If the tank has fluid in it manually gauge
the fluid level (top fluid level for interface displays). Set the
top left display inch reading to match this value using the ↑
UP
or ↓
DOWN
buttons, or to quickly get close to a desired
value, there are three speed buttons:
0
resets the offset to
zero,
1
decreases the offset by 10 inches, and
4
increases the
offset by 10 inches.
9.
The volume calibration (barrel) displays, the 4-20mA/1-5V
outputs, and the alarms will all track with the inch reading, so
it is only required to set the offset once using the inch reading
for the float.
10. Press
ENTER
to store the new offset value, “
Stor
” will be
shown momentarily.
11. LINEAR CALIBRATION MENU:
For a tank with straight
vertical sides, the volume per inch of depth is constant
throughout the tank. In this case, it is not necessary to enter
a complete calibration table; the gauge can calculate the table