Remove the plastic protective cases. 
Although the data is completely degaussed in one operation, 

a second pass rotated at 90 degrees is required to smooth 

out any magnetic fluctuation. 

Note: For DLT media that is to be re-used, a second pass 

is needed. If the second pass is not completed, the tape 

drive may eject the tape and indicate the tape needs 

cleaning. A second pass at 90 degrees will correct this 

condition. If you have any questions, please contact your 

dealer.

First Pass

Second Pass

IMPORTANT SAFETY NOTES

No operator-serviceable parts inside 

unit. Maintenance to be done only by 

trained personnel.

Do not cover chassis ventilation slots 

or block enclosure openings.

High Voltage exists inside unit even 

when equipment is not under power.  

All trouble shooting and wiring checks 

must be performed by a qualified 

electrician or authorized plant 

personnel. 

Check input voltage selection; if 

not compatible with wall voltage, 

have technician qualified by Garner 

Products modify wiring inside this 

system before connecting system 

plug to wall voltage.

A non-shielded power cord may 

be used to connect AC power to 

the system. Use only power cords 

approved by Garner Products

Unplug power cord from the wall to 

disconnect power to the system. 

For continued protection against risk 

of fire, replace fuses with fuses of 

same types and ratings only.

Disconnect main power and unplug 

unit from the wall before installing 

or removing device or servicing 

equipment.

PACE MAKER USERS

Due to stray magnetic fields, consult your physician before operating.

LCD DISPLAY

DEGAUSSING INSTRUCTIONS

The following information appears on 

the LCD Display from power-up through 

one automatic degaussing cycle:

Automatic Degaussing

  Step 1:  Press POWER button ON

GARNER

PRODUCTS, INC.

Displays Manufacturer.

HD-2

DATA ELIMINATOR

Displays Degausser Model.

FIRMWARE VER

##

Displays current firmware version.

TOTAL

#      −−     ##

Displays total erasing cycles. Number on left 

indicates number of times the counter reached 

50,000.

Insert Media

Session = 0

Ready for media to be placed in the Media 

Drawer. Counter for erase cycles from power up.

  Step 2:  Insert media

Drawer Open

Lift drawer up and slide drawer out until it stops. 

Display indicates media drawer is open.

Erase Cycle

Initiated

Closing the drawer automatically starts the 

degauss cycle.

Charging

>>>>>>>>>>>>>>>>

Displays capacitor charging status.

--------------===|==

Visual indicator of erasing field strength. 

Data Eliminated

Indicates power and erasing field strength was 

verified good and data has been eliminated.

  Step 3: Remove Media

Remove Media

Session = 0

Erase cycle has completed.  Open drawer and 

remove media.

Introduction

The degausser model Garner HD-2X and HD-2SS 

are continuous duty capacitive discharge degaussers.  

The unit is designed to erase hard drives and tape 

cartridges that fit inside the drawer.  The convenient 

media loading design accommodates many different 

types and sizes of media, without the need for 

adapters.

Inspection

Inspect the degausser for shipping damage as soon as 

it is unpacked.  If the degausser or any accessories are 

damaged or fail to operate correctly, notify carrier and 

contact your dealer immediately

INITIATION

INSTALLATION

Power Plug

Plug the IEC connector attached to the supplied power 

cord into the receptacle on the back of the unit.

Location

The degausser must be placed on a flat, hard 

surface. Keep at least a 15 cm (6 inch) distance from 

any object that may interfere with the coo ling fan 

exhaust located on the backside of the degausser. 

As a general rule, media not inten ding to be erased 

should be kept about 60 cm (2 ft) away.

Cooling

Forced air-cooling is used to maintain safe ope rating 

temperatures within the degausser. The air intake is 

located on the back panel and the exhaust is through the 

holes in the top panel. To ensure proper cooling, do not 

block the air-intake and maintain at least a 15 cm (6 in.) 

distance from the back of the degausser to any obstacle.

DEGAUSSING INSTRUCTIONS FOR DLT MEDIA

CONTROLS AND INDICATORS

POWER Button (RED):

 The power button switches the power on and off.

Media Drawer:

 The media drawer holds the media to be degaussed and activates and 

deactivates the degaussing cycle when in the closed and open positions.

LCD display:

 The LCD display gives status, automatic count, total count, software version, field 

strength, user instructions and fault messages.

Содержание HD-2 Series

Страница 1: ... 10620 Industrial Avenue Suite 100 Roseville CA 95678 The World Leader In Data Elimination Operation Manual HD 2 SERIES 4075 289 REV 10 HD 2 OPERATION MANUAL 2017 09 21 HD 2SS SpaceSaver HD 2 HD 2X with Data Port Before operating please read the Operating Instructions ...

Страница 2: ... Media Drawer Counter for erase cycles from power up Step 2 Insert media Drawer Open Lift drawer up and slide drawer out until it stops Display indicates media drawer is open Erase Cycle Initiated Closing the drawer automatically starts the degauss cycle Charging Displays capacitor charging status Visual indicator of erasing field strength Data Eliminated Indicates power and erasing field strength...

Страница 3: ...g the magnetic field exposure to 1 second for every 20 pieces of media degaussed Distance from degausser Magnetic field Front Panel Magnetic field Side Duration of Field HD 2X HD 2SS HD 2X HD 2SS 0 mm 0 in 710 gauss 620 gauss 458 gauss 328 gauss 0 05 Second 100 mm 4 in 167 gauss 249 gauss 99 gauss 81 gauss 0 05 Second 200 mm 8 in 68 gauss 85 gauss 52 gauss 26 gauss 0 05 Second 300 mm 12 in 40 gaus...

Страница 4: ...4 of 6 HD 2 SERIES Operation Manual ...

Страница 5: ...TIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND WARRANTIES AGAINST HIDDEN OR LATENT DEFECTS TO THE EXTENT PERMITTED BY LAW IN SO FAR AS SUCH WARRANTIES CANNOT BE DISCLAIMED GARNER LIMITS THE DURATION AND REMEDIES OF SUCH WARRANTIES TO THE DURATION OF THE EXPRESS WARRANTY AND RETURN POLICY DESCRIBED HEREIN LIMITATION OF LIABILITY EXCEPT AS PROVIDED IN THIS WARRANTY AND TO THE MAXIM...

Страница 6: ... 80 2344 4490 Hours Monday through Friday 9 00 a m to 6 00 p m India Standard Time GMT 5 30 hours Email info datalifecycle com Synnex Canada Limited Canada 200 Ronson Drive Toronto Ontario Canada M9W 5Z9 Contact Lucy Sousa Tel 1 416 240 2531 Hours Monday through Friday 9 a m to 6 p m Canada Standard Time GMT 4 hours Email Garner synnex com Varese Secure Ltd United Kingdom Lancaster Court 8 Barnes ...

Отзывы: