background image

NOTICE

If you are connecting this device to an existing NMEA 2000 

network, the NMEA 2000 network should already be connected 

to power. Do not connect the NMEA 2000 power cable to an 

existing NMEA 2000 network, because only one power source 

should be connected to a NMEA 2000 network.
If you are connecting this device to an existing NMEA 2000 

network or engine network by another manufacturer, you should 

install a NMEA 2000 Power Isolator (010-11580-00) between 

the existing network and the Garmin devices.
You can connect the CCU and the optional helm control through 

an existing NMEA 2000 network. If you do not have an existing 

NMEA 2000 network on your boat, all the parts needed to build 

one are supplied in the autopilot package (

Building a Basic 

NMEA 2000 Network for the Autopilot System

, page 7

).

To use the advanced features of the autopilot, optional NMEA 

2000 devices, such as a GPS device, can be connected to the 

NMEA 2000 network.
If you are unfamiliar with NMEA 2000, you should read the 

“NMEA 2000 Network Fundamentals” chapter of the 

Technical 

Reference for NMEA 2000 Products

. To download this 

document, select Manuals on the product page for your device 

at 

www.garmin.com

.

Building a Basic NMEA 2000 Network for the Autopilot 

System

NOTICE

If you are installing a NMEA 2000 power cable, you must 

connect it to the boat ignition switch or through another in-line 

switch. NMEA 2000 devices will drain your battery if the NMEA 

2000 power cable is connected to the battery directly.
A dedicated helm control is not included in all autopilot 

packages. If you install the autopilot without a dedicated helm 

control, the autopilot CCU must be connected to the same 

NMEA 2000 network as a compatible Garmin chartplotter to 

configure and control the autopilot system.

1

Connect the three T-connectors 

À

 together side-by-side.

2

Connect the included NMEA 2000 power cable 

Á

 to a 9 to 

12 Vdc power source 

Â

 through a switch 

Ã

.

You should connect the power cable to the ignition switch of 

the boat if possible, or route it through an inline switch (not 

included).

NOTE: 

The braided drain wire (bare) on the NMEA 2000 

power cable must be connected to the same ground as the 

black wire on the NMEA 2000 power cable.

3

Connect the NMEA 2000 power cable to one of the T-

connectors.

4

Connect one of the included NMEA 2000 drop cables 

Ä

 to 

one of the T-connectors and to the helm control (optional) or 

to a compatible Garmin chartplotter 

Å

.

5

Connect the other included NMEA 2000 drop cable to the 

other T-connector and to the CCU 

Æ

.

6

Connect the male and female terminators 

Ç

 to each end of 

the combined T-connectors.

Connecting the Autopilot Components to an Existing NMEA 

2000 Network

A dedicated helm control is not included in all autopilot 

packages. If you install the autopilot without a dedicated helm 

control, the autopilot CCU must be connected to the same 

NMEA 2000 network as a compatible Garmin chartplotter to 

configure and control the autopilot system.

1

Determine where to connect the CCU 

À

 and the helm control 

(optional) 

Á

 to your existing NMEA 2000 backbone 

Â

.

2

In the location where you plan to connect the CCU, 

disconnect one side of a NMEA 2000 T-connector 

Ã

 from the 

network.

3

If necessary, connect a NMEA 2000 backbone extension 

cable (not included) to the side of the disconnected T-

connector to extend the NMEA 2000 network backbone.

4

Add an included T

connector for the CCU to the NMEA 2000 

backbone by connecting it to the side of the disconnected 

T

connector or backbone extension cable.

5

Route the included drop cable 

Ä

 to the CCU and to the 

bottom of the T-connector added in step 4.
If the included drop cable is not long enough, you can use a 

drop cable up to 6 m (20 ft.) long (not included).

6

Connect the drop cable to the CCU and the T-connector.

7

If needed, repeat steps 2 through 6 for the helm control 

(optional) or a compatible Garmin chartplotter.

Connecting Optional NMEA 2000 Devices to the 

Autopilot System

You can use advanced features of the autopilot system by 

connecting optional NMEA 2000 compatible devices, such as a 

GPS device, to the NMEA 2000 network.

NOTE: 

You can connect optional devices that are not NMEA 

2000 compatible to the helm control through NMEA 0183 

(

NMEA 0183 Connection Considerations

, page 8

).

1

Add an additional T-connector (not included) to the NMEA 

2000 network.

2

Connect the optional NMEA 2000 device to the T-connector 

by following the instructions provided with the device.

7

Содержание REACTOR 40 COMPACT HYDRAULIC

Страница 1: ...w or a rotary cutting tool for installing an optional helm control Wire cutters strippers Phillips and flat screwdrivers Cable ties Single Pole Single Throw SPST switch to use as an autopilot bypass when not installing the Shadow Drive valve Waterproof wire connectors wire nuts or heat shrink tubing and a heat gun Marine sealant Marine corrosion inhibitor spray Portable or handheld compass to test...

Страница 2: ... if needed The Shadow Drive must be mounted horizontally and as level as possible with cable ties firmly securing it in place The Shadow Drive must be mounted at least 305 mm 12 in away from magnetic materials or devices such as speakers or electric motors The Shadow Drive should be mounted closer to the helm than to the pump The Shadow Drive should be mounted lower than the lowest helm but higher...

Страница 3: ...ce To extend this cable use the correct wire gauge Power Cable Extensions page 5 Item Description Important Considerations Ç CCU cable To extend this cable to reach the ECU you may need to use cable extensions sold separately CCU Mounting and Connection Considerations page 1 You must connect this cable to the alarm and the Shadow Drive valve È Pump The pump must be located within 0 5 m 19 in of th...

Страница 4: ...A 2000 network You must connect the helm control or compatible Garmin chartplotter and the CCU to a NMEA 2000 network using the included T connectors NMEA 2000 Connection Considerations page 2 If there is not an existing NMEA 2000 network on your boat you can build one using the supplied cables and connectors Building a Basic NMEA 2000 Network for the Autopilot System page 7 Å CCU You can mount th...

Страница 5: ... ECU as a template 2 Using a drill bit appropriate for the mounting surface and selected mounting hardware drill the four holes through the mounting surface 3 Secure the ECU to the mounting surface using the selected mounting hardware Connecting the ECU to Power WARNING When connecting the power cable do not remove the in line fuse holder To prevent the possibility of injury or product damage caus...

Страница 6: ... the Alarm page 6 If the cable is not long enough extend the appropriate wires with 0 08 mm2 28 AWG wire Installing the Shadow Drive Valve Connecting the Shadow Drive Valve to the Hydraulic System Before you can install the Shadow Drive valve you must select a location at which to connect the Shadow Drive to the hydraulic steering of your boat Shadow Drive Mounting Considerations page 2 For furthe...

Страница 7: ...wer cable must be connected to the same ground as the black wire on the NMEA 2000 power cable 3 Connect the NMEA 2000 power cable to one of the T connectors 4 Connect one of the included NMEA 2000 drop cables Ä to one of the T connectors and to the helm control optional or to a compatible Garmin chartplotter Å 5 Connect the other included NMEA 2000 drop cable to the other T connector and to the CC...

Страница 8: ...he helm control is not included in all autopilot packages A helm control must be installed in your autopilot system to connect NMEA 0183 devices according to these diagrams If you install the autopilot without a helm control all NMEA devices you plan to use with the autopilot system must be connected to a compatible Garmin chartplotter on the same NMEA 2000 network as the CCU See the installation ...

Страница 9: ... NMEA 2000 bus and the NMEA 0183 device to a common ground Specifications Compact Pump Specification Measurement Dimensions H W D 84 6 x 100 3 x 155 3 mm 3 3 4 0 6 1 in Weight 2 2 kg 5 lb Temperature range From 15 to 75 C from 5 to 167 F Material Motor frame Powder coat gloss black Motor end caps Cast aluminum ADC12 Pump body and cap Anodized die cast ADC12 Mounting bracket 304 stainless steel ECU...

Страница 10: ... dtm gll rmb vhw mwv xte Error and Warning Messages Error Message Cause Autopilot Action ECU Voltage is Low The pump supply voltage has fallen below 10 Vdc for longer than 6 seconds Alarm sounds for 5 seconds Continues in normal operation Autopilot is not receiving navigation data Autopilot placed in Heading Hold The autopilot is no longer receiving valid navigation data while performing a Route T...

Страница 11: ... Europe call 44 0 870 850 1241 2017 Garmin Ltd or its subsidiaries Garmin and the Garmin logo are trademarks of Garmin Ltd or its subsidiaries registered in the USA and other countries Reactor and Shadow Drive are trademarks of Garmin Ltd or its subsidiaries These trademarks may not be used without the express permission of Garmin NMEA NMEA 2000 and the NMEA 2000 logo are trademarks of the Nationa...

Страница 12: ......

Отзывы: