APPENDIX A SHIELD BLOCK CONNECTOR INSTALLATION
INSTRUCTIONS
A.1 Shield Block Installation Parts
Table 2-3
and Table A-1 list the parts needed to install a Shield Block. Parts listed in
Table 2-3
are
supplied in the GTR 200/200B Connector Kit (011-003240-00) and the GTR 200/200B Connector Kit
FAA-PMA (011-003240-01). Parts listed in Table A-1 are to be provided by the installer.
Table A-1 Parts not supplied for a Shield Block Installation (
Figure A-1
)
Figure
Ref
Description
GPN or MIL spec
4
Multiple Conductor Shielded Cable (2-conductor shown in
Figure A-1
)
Parts used depend on
method chosen
5
Drain Wire Shield Termination (method optional)
Parts used depend on
method chosen
6
Braid, Flat (19-20 AWG equivalent, tinned plated copper strands
36 AWG, Circular Mil Area 1000 -1300)
Parts used depend on
method chosen
7
Floating Shield Termination (method optional)
Parts used depend on
method chosen
13
Silicon Fusion Tape
-