400 SERIES MAINTENANCE MANUAL
Page 5-47
P/N 190-00140-05
Rev. C
Figure 5-9. Main CDI/OBS Configuration Test Page
5.7.6.13
MAIN Lateral LEFT, RIGHT Outputs
Measure J1-21 (output) relative to J1-22 (output) [Load—333 ohms (three 1000 ohm loads)
across J1-21 and J1-22]. Note that full left/right (
r
150 mV) are also available selections but are
not tested.
MAX LEFT ______ (+300
r
15 mV)
CENTER ______ (0
r
4.5 mV)
MAX RIGHT ______ (-300
r
15 mV)
5.7.6.14
MAIN Vertical UP, DOWN Outputs
1.
Measure J1-27 (output) relative to J1-28 (output) [Load—333 ohms (three 1000 ohm loads)
across J1-27 and J1-28].
2.
Note that full up/down (
r
150 mV) are also available selections but are not tested.
MAX UP ______ (+300
r
30 mV)
CENTER ______ (0
r
4.5 mV)
MAX DOWN ______ (-300
r
30 mV)
5.7.6.15
MAIN To/From Output
Measure J1-25 relative to J1-26. Load—67 ohms (Three 200 ohm loads) across J1-25 and J1-26.
TO ______ (+190
r
40 mV)
HIDDEN ______ (0
r
5 mV)
FROM ______ (-190
r
40 mV)